JA-110E
Bus keypad
A bus keypad with an LCD display, a numeric keypad and a 125 kHz RFID reader. It is operated with four function buttons A–D, each with its own separate status indicator. The design is fixed, and the IN input can also take a door opening detector, so there is one peripheral fewer on the entrance door.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- RFID frequency
- 125 kHz
- Classification
- Grade 2 (if selected in the F-Link SW)
- Size
- 120 x 130 x 30 mm
Basic description
The JA-110E is a bus keypad with a display for installations where four function buttons and a fixed design are enough. It combines system control and authorisation in a single panel at the entrance. It cannot be extended; if the customer wants to add control elements, the modular JA-114E access module is chosen.
- Each button can handle a different task. You assign fifteen functions to buttons A–D, from setting and unsetting a section to a hold-up alarm, fire or control of a PG output.
- Authorisation by card and by code. The 125 kHz RFID reader works in four operating modes according to the needs of the building.
- Faster installation of further units. The Import button in F-Link takes over the settings from another keypad of the same type.
- An overview right on the keypad. The display shows the time, a user text and the temperature of a selected detector, and during an alarm its type, section and source.
Why choose this product
Control and authorisation
You assign each button one of fifteen functions, including unsetting and setting a section, part setting, a hold-up alarm, fire, a medical emergency and control of a PG output. The Section selection and Controls PG functions allow control by authorisation alone, i.e. without pressing a function button. The RFID reader offers the Permanently ON, Activated by pressing, Disabled, or Activated by pressing or authorisation requirement modes.
- Four function buttons A–D and four status indicators
- 125 kHz RFID reader in four operating modes
- Fifteen functions per button, hold-up alarm delay of 1 to 255 s
Power supply and installation
The Permanently ON option of the RFID reader ignores the wake-up settings and permanently increases the current draw. Screw the rear plastic to the chosen place; it is recommended to use all four mounting holes for reliable tamper protection.
- Power and communication via the control unit bus (9 to 15 V)
- Rear tamper protection requires two screws in the prescribed holes
- Dimensions 120 × 130 × 30 mm, weight 217 g
Use in the system
The Import button copies the settings from another keypad of the same type in the system and offers a history of the most recent settings of the given position.
- Non-shared data bus, no radio module
- Enrolment and internal settings in F-Link, Devices tab
- Security grade 2, if set in F-Link
Frequently asked questions
When four function buttons with a display are enough. The JA-110E has a fixed design; its four buttons A–D cannot be extended. If the customer wants more control elements or will be adding them over time, choose the JA-114E access module, which is made up of JA-192E segments.
A door opening detector. The input reacts to opening against the GND terminal, and you set the control unit's reaction to its activation in F-Link. The detector type is not specified, so the input can stand in for a separate peripheral on the entrance door. Door opening and control of the security system are handled by one device at the entrance.
Contactless cards and tags at 125 kHz. NFC identifiers at 13.56 MHz do not work with this reader.
Technical specifications
- Power
- from control panel digital bus (9…15 V)
- Nominal current consumption to calculate back up
- 30 mA
- Current consumption for cable selection
- 110 mA
- Connection type
- data BUS – not shared
- RFID frequency
- 125 kHz
- Size
- 120 x 130 x 30 mm
- Weight
- 217 g
- Classification
- Grade 2 (if selected in the F-Link SW)
- according to
- EN 50131-1, EN 50131-3, T 031
- Operational environment according to
- EN 50131-1 II. Indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75% RH
- Certification body
- Trezor Test
- Complies with
- ETSI EN 300330-2, EN 50130-4, EN 55032, EN 60950-1, ETSI EN 301 489
- Can be operated according to
- ERC REC 70-03
Warning
- A delayed hold-up alarm is cancelled by pressing the same button a second time. Security grade 2 only applies if it is set in F-Link, and for certified use, the appropriate configuration scheme must be selected on the Parameters tab. Without the rear plastic screwed on with at least two screws in the prescribed holes, the rear tamper protection does not work properly. The keypad cannot be extended; four function buttons are a design limit. Do not apply the Authorisation unsets a section with entry delay running option to the Common section, as all the assigned sections and the whole system may be unset unintentionally. The Permanently ON option of the RFID reader ignores the wake-up settings and permanently increases the current draw from the bus; in the Activated by pressing mode, the reader activates for 3 s. When dimensioning the back-up, allow for 30 mA, and when choosing the cable, for a maximum current draw of 110 mA. In the Service mode, the function buttons are neither lit nor available, and the menu is not available to users or managers; the menu is only available to the service engineer if no computer is connected to the control unit. A permanently lit red indicates BOOT mode on the JA-110E, whereas on the JA-115E BOOT is indicated by slow flashing of yellow; beware of confusing them during servicing. The energy-saving sleep mode with limited indication is only active with the EN 50131-1 and Incert profiles. Connect the bus only with the system power supply completely switched off. The environment is indoor – general, −10 to +40 °C and 75 % RH.
Installation example
Always connect the bus with the system power supply completely switched off.
Press the latch on the bottom and release the front plastic from the rear plastic.
Screw the rear plastic to the chosen place. Use all four mounting holes; at least two screws belong in the hole closest to the tamper contact opening and in the diagonally opposite corner.
For easier wiring, you can slide out the bus terminal block and put it back after connecting the cable.
Connect the bus wires; connect any door opening detector to the IN input against the GND terminal.
Click the keypad into the rear plastic. Make sure that the wires do not touch the spring of the tamper contact.
Secure the keypad with the small screw supplied.
Switch on the system power. In F-Link, switch on Enrol and double-click the peripheral in the list of unenrolled devices. It can also be enrolled by pressing the cover or the tamper contact, or by entering the full serial number below the bar code.
In F-Link, set the functions of buttons A–D, the RFID reader mode, the backlight intensity, the display contrast and the hold-up alarm delay.
For certified use, select the appropriate configuration scheme in F-Link on the Parameters tab.
Related products

JA-112E
Bus RFID Access Module

JA-113E
Bus Access Module with keypad and RFID

JA-114E
Bus Access Module with display, keypad and RFID

JA-116E
Bus touchscreen keypad with RFID reader

JA-115E
Bus four-segment keypad with display and RFID reader

JA-120E-WH
Bus outdoor RFID / NFC reader - white

JA-120E-BK
Bus outdoor RFID / NFC reader - black

JA-121E-WH
Bus outdoor keypad with RFID / NFC reader - white

JA-121E-BK
Bus outdoor keypad with RFID / NFC reader - black

JA-122E-NFC
Bus outdoor RFID reader 13.56 MHz

JA-123E-NFC
Bus outdoor keypad with RFID reader 13.56 Mhz

DE06-12
Power supply 12 V/0.5 A
Help us improve the catalog
Missing something, or found a mistake? Let us know.