JA-161PW
Wireless PIR and MW combined detector
A wireless detector, part of the JABLOTRON 100+ system, combining a PIR and a microwave section in a compact design; it only sends an alarm once both confirm it. PIR coverage angle 110° and range 12 m. It communicates by radio and is powered by batteries.
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- 2x alkaline battery, type LR6 (AA) 1.5 V / 2.45 Ah Please note: Batteries are not included.
- Typical lifetime of batteries
- approx. 2 years
- Low battery voltage
- <2.4 V
- Quiescent current consumption
- 70 µA
- Maximal current consumption
- 40 mA
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- <25 mW
Basic description
The JA-121PW and JA-161PW are compact versions of the dual PIR and microwave principle for standard interiors, without the GR/AN versions. Industrial premises and glazed areas are covered by their siblings, the JA-122PW and JA-162PW, with GR/AN versions and support for the JA-191PL bracket.
- Dual PIR and microwave principle, part of the JABLOTRON 100+ system. An alarm is only raised once both principles confirm it; a thermal effect on its own does not cause an alarm.
- Installation without cables. Battery-powered; installation requires no cabling and no chasing into walls.
- PIR coverage angle 110° and range 12 m. The microwave section confirms within a 90° coverage angle up to 12 m.
- Dual evaluation in one module. Occupies one system position.
Why choose this product
Dual principle: an alarm only when both agree
When the PIR registers movement, the microwave section is activated and confirms it; only when both agree is an alarm raised. A thermal change on its own, such as a draught or sunshine, does not cause an alarm.
- Wireless transmission at 868 MHz, range approximately 300 m
- PIR coverage 110° / 12 m, microwave 90° / 12 m
- Occupies one system position
For demanding environments
The dual principle is suitable where a PIR on its own reports false alarms, for example near heating or in a room with direct sunlight.
- PIR and microwave immunity adjustable in F-Link
- Microwave sensitivity adjustable in F-Link
- The tamper contact reports opening of the cover
Microwave specifics
Microwaves can pick up movement even behind a non-metallic obstacle, so aim the detector away from areas with regular movement behind a partition and carry out a test after installation. Several microwave transmitters close to each other may interfere with each other.
- Microwaves pass through non-metallic obstacles (wall, door, glass)
- Only one microwave detector per room
- Recommended installation height approximately 2.5 m
Frequently asked questions
The detector combines a passive infrared sensor and a microwave sensor. An alarm is only raised on simultaneous detection by both, which reduces the number of false alarms.
In an environment with draughts, heating or direct sunlight, where a PIR on its own reports false alarms caused by thermal effects. The dual principle confirms the movement with a second, independent sensor.
The JA-162PW uses the same dual principle, and in addition offers GR/AN versions with increased immunity to white light and support for the JA-191PL bracket. The JA-161PW is a more compact design for standard interiors.
Technical specifications
- Power
- 2x alkaline battery, type LR6 (AA) 1.5 V / 2.45 Ah Please note: Batteries are not included.
- Typical lifetime of batteries
- approx. 2 years
- Low battery voltage
- <2.4 V
- Quiescent current consumption
- 70 µA
- Maximal current consumption
- 40 mA
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- <25 mW
- Recommended installation height
- 2.5 m
- Detection angle / detection coverage (PIR)
- 110 ° / 12 m
- Detection angle / detection coverage (MW)
- 90 ° / 12 m
- Operating frequency MW
- 24.125 GHz
- Maximum effective radiated power MW (EIRP)
- 50 mW
- Dimensions
- 60 x 98 x 52 mm
- Weight (without batteries)
- 93 g
- Classification
- security grade 2 / environmental class II (according to EN 50131-1)
- Environment
- indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operating range
- 75% RH, non-condensation
- Certification body
- Trezor Test s.r.o. (no. 3025)
- In compliance with
- EN IEC 63000, EN 50130-4, EN 55032, EN 50131-1, -2-4, -5-3, -6, EN IEC 62368-1, EN ETSI 300 220-1, -2, EN ETSI 300 440
- Can be operated according to
- ERC REC 70-03
- MW Frequency band according to ERC REC 70-03
- band m)
- ITU designation for MW
- P0N
- ITU designation for SRD
- 80K0F1DAN
- Recommended screw
- 2x ø 3.5 x 40 mm (countersunk head)
Warning
It is not possible to mount multiple MW detectors with overlapping fields of view - they interfere with each other. The microwave signal passes through walls - orient the detector in the right direction.
- Do not touch the PIR sensor inside, you could damage it. Do not install two microwave detectors in one room; their transmitters would interfere with each other. Microwaves pass through non-metallic obstacles, so carry out a test after installation and reduce the sensitivity if necessary. The control unit must contain a JA-11xR radio module, and always replace both batteries together.
Installation example
Mount it no more than 2.5 m above the floor; do not install more than one unit in an area where the microwave detectors could interfere with each other.
Open the cover by pressing the latch, do not touch the PIR sensor inside, and take out the electronics.
Screw the rear plastic to the wall and put the electronics back in.
Insert both batteries and enrol the detector according to the control unit manual; the control unit must have a JA-11xR radio module. Set the PIR and MW immunity and the MW sensitivity in F-Link.
Close the cover, secure it with the locking screw and check the coverage.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer

JA-151TH
Wireless temperature detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.