JA-102KY
Mercury control panel JA-102KY
JABLOTRON Mercury security system control unit for smaller installations managed from a mobile app. Mobile connectivity is built into the control unit, so notifications go to the Alarm Receiving Centre directly from it. The JA-102KY is the bus version; the radio module is purchased separately.
Product line
- JABLOTRON Mercury
Key specifications
- Max. number of sections
- 4
- Max. number of peripherals
- 31 peripherals + 31 drivers
- Max. number of PG outputs
- 2
- Max. number of users
- 32
- Max. continuous consumption from control panel
- 1000 mA
- Back-up battery
- 12 V; 2.6 Ah max (lead gel)
- Alarm device classification
- Security level 2 / environment class II
- Dimensions
- 268 x 225 x 83 mm
Basic description
The JABLOTRON Mercury platform has three control units with the same system capacity and the same operation from the mobile app. The JA-102KY is a bus unit and the radio module is purchased separately. The JA-102KRY is supplied with a radio module, so it handles both bus and wireless devices with no further purchase. The JA-152KRY is fully wireless and suits places where data cabling cannot be run; however, it has neither a bus nor a secondary LAN path. For larger systems, use the JABLOTRON 100+ platform.
- Covers a smaller installation. The system supports 31 peripherals, 31 remote controls, 32 users and 4 sections.
- Mobile connectivity is built into the control unit. Notifications go to the Alarm Receiving Centre over the mobile network via a SIM card that cannot be removed or replaced.
- Connect bus peripherals without any additional module. Add wireless with a JA-11xR radio module on the I-BUS connector.
- Set it up and run it from a mobile app. Configuration is done in MyCOMPANY, the user controls the system in MyJABLOTRON, and operation is tied to a monthly fee for the JDS service.
Why choose this product
How large an installation the control unit covers
JABLOTRON Mercury control units are designed for smaller installations controlled from a phone: a flat, family home, office or business premises. The capacity is fixed and cannot be extended, so allow for spare capacity at the design stage.
- Up to 31 peripherals and 31 remote controls
- 32 users and 4 separate sections
- 2 control outputs, preset for a garage door and an entrance gate
What you can connect to the control unit
Notifications to the Alarm Receiving Centre always go over the mobile network; how the peripherals themselves connect differs between the versions. Bus devices are connected by cable and need no batteries; wireless devices suit places where you cannot chase into walls.
- Bus peripherals on one terminal block; the LAN interface serves only as a secondary path
- Wireless peripherals require a JA-11xR radio module, purchased separately
- With the mobile path and the secondary LAN path, it achieves classification DP2 to DP4
Power supply, backup and classification
How long the system runs without mains power depends on the capacity of the rechargeable battery and on how many devices are installed in the system. Calculate this when designing the installation, not when commissioning the system.
- Back-up battery 12 V / 2.6 Ah, lead-acid gel
- 12-hour backup with a total consumption of up to 115 mA
- Security grade 2, environmental class II
Frequently asked questions
Yes, and it is included in the price of the control unit. Mobile connectivity is integrated through a special SIM card that cannot be removed or replaced. The JA-11xR radio module is purchased separately if the installation is to include wireless peripherals.
Technical specifications
- Instalation type
- Fixed instalation
- Control panel power supply / frequency / fuse
- ~ 110-230 V/50-60 Hz, max. 0.28 A with F1.6 A/250 V fuse, protection class II
- Power / current
- max 23 VA / 0.1 A
- Protection class
- II.
- Back-up battery
- 12 V; 2.6 Ah max (lead gel)
- Low backup battery voltage (fault indication)
- ≤11 V
- Maximum battery recharge time (80% capacity)
- 72 h
- Bus supply voltage / max ripple (red - black)
- 12.0 ÷ 13.8 VDC / ±100 mV
- Max. continuous consumption from control panel
- 1000 mA
- - with 12 h backup (2.6 Ah battery)
- Without GSM communicator | LAN - off: 115 mA | LAN - on: 88 mA
- Max. number of sections
- 4
- Max. number of peripherals
- 31 peripherals + 31 drivers
- Max. number of users
- 32
- Max. number of PG outputs
- 2
- Alarm connections
- Jablotron bus - dedicated cable connection Wireless connection (with JA-111R) - non-specific wireless connection, wireless Jablotron protocol
- Alarm device classification
- Security level 2 / environment class II
- - In accordance with
- EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2
- - Environment
- Indoor general
- - Operating temperature/humidity range
- -10 °C to +40 °C/75% non-condensing
- - Power supply
- Type A - primary power supply with rechargeable backup battery
- - Event memory capacity
- of approx. 7 million recent events including source, date and time
- - system response to loss of communication with periphery
- Fault or Sabotage - depending on settings and profile bus up to 10 s wireless communication up to 2 h (since last communication) wireless communication within 20 min prevents securing the section
- - System reaction to incorrectly entered codes
- after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes.
- - ATS classification
- Supported ATS classes: SP2 - SP5, DP2 - DP4 SPT: Type Z Type of operation: Pass-through LAN on board: SP2 - SP5 (with IP protocol) JA-194Y LITE SP3 - SP5 (JABLO IP, ANSI SIA, DC-09) LAN + JA-194Y LITE DP2 - DP4 JABLO IP, ANSI SIA, DC-09)
- - ATS alarm transmission protocols
- JABLO IP, SIA IP, Contact ID,
- - ATC security against substitution and information protection
- Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key DC-09.2012 protocol with 128-bit AES encryption
- LAN communicator
- Ethernet interface CAT 5 (RJ-45)
- Dimensions
- 268 x 225 x 83 mm
- Weight with/ without ACU
- 1809 g/919 g
- Basic parameters of the JA-111R module
- 868.1 MHz, <25 mW, GFSK <80 kHz
- Radio emission
- ETSI EN 300 220-2 (JA-111R module)
- EMC
- EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3
- Electrical safety
- EN IEC 62368-1
- Conditions of operation of the CTU radio module
- ERC REC 70-03
- Certification body
- TREZOR TEST (No. 3025)
Warning
- Always connect the bus with the system power completely switched off. Operation requires a regular monthly payment for the JDS service. Without payment the system remains functional locally, but control via MyJABLOTRON and configuration via MyCOMPANY will be cancelled.
- The bus must not form a closed loop anywhere, the ends of the branches must not be joined, and do not connect the shielding to GND or to any other terminal of the control unit.
- The total continuous consumption of the bus peripherals must not exceed 110 mA. Above this limit, the system does not provide the 12-hour backup required by the standard.
- The I-BUS connector is reserved for the JA-11xR radio module. Do not connect ordinary peripherals to it; they belong on the BUS terminal block.
- Never connect the power supply or the battery while the GSM antenna is disconnected. Do not regard the fuse holder as a means of safe disconnection.
- A control unit on the same LAN as active 48 V PoE power may communicate unreliably. Use a PoE splitter.
- The battery takes 72 hours to charge to 80% of capacity. Immediately after commissioning, the backup is therefore not yet fully available.
- A wireless communication failure with a peripheral lasting longer than 20 minutes prevents the section from being set. The supervision period for wireless devices is 2 hours from the last communication.
- After 10 incorrectly entered codes, the control unit triggers a tamper alarm and, depending on the profile, blocks all control devices for 10 minutes.
Installation example
The control unit may only be installed by a trained technician holding a valid JABLOTRON certificate. The mains supply may only be connected by a person with a professional electrical qualification.
Check for good GSM signal at the installation site and the availability of a permanent mains supply.
Fix the control unit in a concealed place in an indoor environment; do not connect the power yet.
Install the bus peripherals and connect them with CC-02 cable; never join the ends of the branches.
Connect the mains supply according to the technical documentation.
Insert the 12 V / 2.6 Ah rechargeable battery, secure it with the strap and connect it, observing the polarity.
Switch on the power and wait until the red GSM LED goes off.
In the MyCOMPANY app, select a new installation and scan the barcode of the control unit serial number.
Check the GSM signal quality in the app.
Add the peripherals by scanning their barcodes.
Set up the users and change the default codes for Service and Manager.
Test the peripherals, close the control unit cover and exit service mode.
If the installation needs wireless peripherals, add a JA-11xR radio module to the I-BUS connector.
Help us improve the catalog
Missing something, or found a mistake? Let us know.