JA-152KRY
Mercury control panel JA-152KRY
JABLOTRON Mercury security system control unit for smaller installations managed from a mobile app. Mobile connectivity is built into the control unit, so notifications go to the Alarm Receiving Centre directly from it. The JA-152KRY is fully wireless: no bus, no LAN interface, no data cabling.
Product line
- JABLOTRON Mercury
Key specifications
- Maximum number of sections
- 4
- Maximum number of devices
- 31 devices + 31 remote controllers
- Max. number of PG outputs
- 2
- Maximum number of users
- 32
- Back-up battery
- 3.7V, 5000 mAh, Li-Polymer
- Classification of Alarm device
- Security Grade 2 / Environment Grade II
- Dimension
- 182 x 132 x 58 mm
Basic description
The JABLOTRON Mercury platform has three control units with the same system capacity and the same operation from the mobile app. The JA-102KY is a bus unit and the radio module is purchased separately. The JA-102KRY is supplied with a radio module, so it handles both bus and wireless devices with no further purchase. The JA-152KRY is fully wireless and suits places where data cabling cannot be run; however, it has neither a bus nor a secondary LAN path. For larger systems, use the JABLOTRON 100+ platform.
- Covers a smaller installation. The system supports 31 peripherals, 31 remote controls, 32 users and 4 sections.
- Mobile connectivity is built into the control unit. Notifications go to the Alarm Receiving Centre over the mobile network via a SIM card that cannot be removed or replaced.
- Install it without a single data cable. The control unit has neither a bus nor a LAN; all peripherals communicate by radio.
- Set it up and run it from a mobile app. Configuration is done in MyCOMPANY, the user controls the system in MyJABLOTRON, and operation is tied to a monthly fee for the JDS service.
Why choose this product
How large an installation the control unit covers
JABLOTRON Mercury control units are designed for smaller installations controlled from a phone: a flat, family home, office or business premises. The capacity is fixed and cannot be extended, so allow for spare capacity at the design stage.
- Up to 31 peripherals and 31 remote controls
- 32 users and 4 separate sections
- 2 programmable outputs (PG), preset for a garage door and an entrance gate
What you can connect to the control unit
Notifications to the Alarm Receiving Centre always go over the mobile network. All peripherals connect to the control unit by radio, so it suits places where you cannot chase into walls.
- The control unit has neither a BUS terminal block nor a LAN interface
- The radio module is integrated in the control unit; peripherals communicate at 868.1 MHz
- Without a second transmission path, only classifications SP2 to SP5 are available, none of the DP type
Power supply, backup and classification
How long the system runs without mains power depends on the capacity of the rechargeable battery and on how many devices are installed in the system. Calculate this when designing the installation, not when commissioning the system.
- Li-Polymer back-up battery 3.7 V / 5000 mAh, type BAT-3V7/5000
- Peak consumption of the communicator is 720 mA
- Security grade 2, environmental class II
Frequently asked questions
Yes. The 4G LITE communicator is built into the control unit and the SIM card cannot be removed or replaced. The radio module is integrated too, so nothing else needs to be purchased for wireless peripherals.
Technical specifications
- Installation type
- Fixed installation
- Control panel power supply
- ~ 110 – 230 V/50 – 60 Hz, max. 0.28 A with F1.6 A/250 V fuse, security grade II
- Electrical power / current
- Max. 23 VA / 0.1 A
- Protection class
- II.
- Back-up battery
- 3.7V, 5000 mAh, Li-Polymer
- Low battery backup voltage (fault indication)
- ≤3.5V
- Maximum battery recharge time (80% capacity)
- 72 h
- Maximum number of sections
- 4
- Maximum number of devices
- 31 devices + 31 remote controllers
- Maximum number of users
- 32
- Max. number of PG outputs
- 2
- Alarm connections
- Wireless connection– unspecified wireless connection, Jablotron wireless protocol
- Classification of Alarm device
- Security Grade 2 / Environment Grade II
- @ According to standards
- EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3, EN 50131-10, EN 50136-1, EN 50136-2
- @ Environment
- Indoor general
- @ operational temperature range / humidity range
- -10 °C to +40 °C / 75% RH without condensation
- @ power supply
- Type A – primary mains power supply with a powered back-up battery.
- @ event memory capacity
- approx. 7 million events, including sources and timestamps.
- @ system reaction to loss of device communication
- Fault or Tamper – Dependent on selected profile
- @ wireless communication within
- 2h (from last communication)
- @ Wireless communication within
- 20min blocks section setting
- @ system reaction to incorrect code entry
- Alarm after 10 wrong code entries, dependent on selected profile, the system will be locked for ten minutes.
- @ ATS classification
- Supported ATS classes: SP2 – SP5, SPT: type Z Operation type: Pass-Through GSM2201MD SP3 – SP5 (JABLO IP, ANSI SIA, DC-09)
- @ ATS Alarm transmission protocols
- JABLO IP
- @ ATC security against substitution and protection of information
- Jablotron protocols: proprietary AES encryption with a minimally 128 bit key ANSI SIA DC-09.2012 protocol with 128 bit AES encryption
- Dimension
- 182 x 132 x 58 mm
- Weight with battery / without battery
- 510 g/430 g
- Based parameters of the JA 111R module
- 868.1 MHz, <25 mW, GFSK <80 kHz
- Radio emissions
- ETSI EN 300 220-1,2
- EMC
- EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3
- Safety conformity
- EN IEC 62368-1
- Conditions of operation
- ERC REC 70-03
- Certification body
- TREZOR TEST (no. 3025)
Warning
- Always connect the bus with the system power completely switched off. Operation requires a regular monthly payment for the JDS service. Without payment the system remains functional locally, but control via MyJABLOTRON and configuration via MyCOMPANY will be cancelled.
- The control unit has neither a BUS terminal block nor a LAN interface. If the project needs a bus or a secondary path, choose the JA-102KRY.
- Only a 3.7 V / 5000 mAh Li-Polymer rechargeable battery of type BAT-3V7/5000 belongs in the control unit. Neither a lead-acid battery nor any other type belongs here.
- Good GSM signal is a prerequisite for operation, because the mobile network is the only transmission path. Check it at the installation site before installation.
- The battery takes 72 hours to charge to 80% of capacity. Immediately after commissioning, the backup is therefore not yet fully available.
- A wireless communication failure with a peripheral lasting longer than 20 minutes prevents the section from being set. The supervision period for wireless devices is 2 hours from the last communication.
- After 10 incorrectly entered codes, the control unit triggers a tamper alarm and, depending on the profile, blocks all control devices for 10 minutes.
Installation example
The control unit may only be installed by a trained technician holding a valid JABLOTRON certificate. The mains supply may only be connected by a person with a professional electrical qualification.
Check for good GSM signal at the installation site and the availability of a permanent mains supply.
Fix the control unit in a concealed place in an indoor environment; do not connect the power yet.
Position the wireless peripherals so that their radio communication is neither shielded nor subject to interference.
Connect the mains supply according to the technical documentation.
Insert the 3.7 V / 5000 mAh Li-Polymer rechargeable battery, fix it to the board with double-sided adhesive tape and plug in its connector. The battery is supplied charged and must not be short-circuited.
Switch on the power and wait until the red GSM LED goes off.
In the MyCOMPANY app, select a new installation and scan the barcode of the control unit serial number.
Check the GSM signal quality in the app.
Add the peripherals by scanning their barcodes.
Set up the users and change the default codes for Service and Manager.
Test the peripherals, plug in the acoustic indicator connector and close the control unit cover.
Exit service mode and test the system function.