JA-111R
Bus interface for JA-100 wireless devices
Bus radio module that provides communication between the control unit and the wireless peripherals of the system. It is supplied as a bare electronics board without a cover.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Compatible with
- F-Link 1.4.0 or higher
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption in standby mode
- 35 mA
- Current consumption for cable selection (maximum)
- 80 mA
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- 25 mW
- RF range
- 300 m
Basic description
With these three modules, the deciding factor is which peripherals you want to link to the bus. The JA-111R 80 communicates with the wireless peripherals of the previous-generation JA-80 Oasis system, i.e. with JA-8x series detectors and RC-8x series remote controls. The JA-111R and JA-112R work with the wireless peripherals of the current system.
- Creates a radio interface between the control unit bus and the wireless peripherals.
- It is powered with DC voltage from the control panel bus and is connected with the system power completely switched off.
- Used to connect the wireless peripherals of the current system; it can be placed directly in the control unit or outside it in its own cover.
- Complies with Security Grade 2 and environmental class II according to EN 50131-1; this applies only with the correct system profile selected in F-Link.
Why choose this product
What the module enables and how it is configured
The module is enrolled to the control unit in the F-Link software, by selecting an unassigned position or by entering the serial number. The control unit then communicates with the wireless peripherals through it.
- Until the module is enrolled, the yellow LED indicates this by flashing; after enrolment, it goes off.
- One radio module is connected to one connector of the control unit.
- It can also transmit a learning signal for peripherals that have only a receiver, such as the JA-150N.
What the control unit provides for it
It only requires a free position for the radio module in the system; configuration is done in the F-Link software.
- The system holds a maximum of three radio modules; this one occupies one position.
- Operating conditions are governed by the general authorisation of the Czech Telecommunication Office (ČTÚ).
- It detects radio interference at two sensitivity levels: at low, it reports interference lasting longer than 30 seconds within one minute; at high, interference lasting longer than 10 seconds within twenty.
Where it is installed
The location determines the range. In open space, radio modules must not be installed close to each other; in a built-up space, one wall between them is sufficient.
- Power supply 12 V DC from the bus, within the range 9 to 15 V.
- A distance of at least 2 metres from metal and electrical wiring, and at least 10 metres between radio modules in open space.
- After installation, check the signal strength in the F-Link diagnostics; it should not fall below 20%.
Frequently asked questions
A maximum of three; this one occupies one position.
Peripherals of the current system will; the compatibility overview on the website confirms the exact list.
Technical specifications
- Compatible with
- F-Link 1.4.0 or higher
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption in standby mode
- 35 mA
- Current consumption for cable selection (maximum)
- 80 mA
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- 25 mW
- RF range
- 300 m
- Dimensions
- 43 x 160 x 23 mm
- Weight (PBC only)
- 70 g
- Classification
- Security grade 2 / Environmental class II / ACE type B (According to EN 50131-1)
- Operational environment
- Indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025), Telefication B.V.
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, ETSI EN 300 220-1-2, EN 50130-4 ed. 2+A1, EN 55032, EN 62368-1, EN 50581, T 031
- Can be operated according to
- ERC REC 70-30
Warning
- Always connect the bus with the system power completely switched off. The default system profile does not meet the requirements of Security Grade 2; select the appropriate profile in F-Link.
Installation example
Choose a location at least 2 m away from metal objects and electrical wiring, ideally also 2 m from the control unit.
Fit the module into the holder in the control unit, or place it outside the control unit in a PLV-JA111R cover.
Always connect the bus with the system power completely switched off.
Enrol the module in the F-Link software using Scan/add new BUS devices, or by entering the serial number.
Check the tamper contact and the signal strength in the F-Link diagnostics; it should not fall below 20%.
Related products

JA-103K
Control panel JA-103K

JA-107K
Control panel JA-107K

JA-108K
Control panel JA-108K

JA-102KRY
Mercury control panel JA-102KRY

JA-103KR
Control panel JA-103KR

JA-103K-7AH
Control panel JA-103K-7AH

JA-107KR
Control panel JA-107KR

JA-102KY
Mercury control panel JA-102KY

JA-121T
RS-485 bus interface

JA-112R
Bus module for connecting JA-100 wireless components

JA-150R
One-way signal repeater for JA-100 wireless devices

JA-152KRY
Mercury control panel JA-152KRY
Help us improve the catalog
Missing something, or found a mistake? Let us know.