JA-103K
Control panel JA-103K
JABLOTRON 100+ system control unit for family homes, offices and smaller commercial premises. It combines bus and wireless peripherals and divides them into separate sections. The JA-103K is the basic version of the range.
Product line
- JABLOTRON 100+
Key specifications
- Number of sections
- 8
- Maximum number of devices
- 50
- Max. number of PG outputs
- 32
- Maximum number of users
- 50
- Maximum continuous current consumption from the control panel
- 1000 mA
- Back-up battery
- 12 V; 2.6 Ah (lead gel)
- Classification
- Security grade 2 according to EN 50131-1
- Dimensions
- 268 x 225 x 83 mm
Basic description
The JA-103 range has three versions with the same electronics and the same system capacity. The JA-103K is the basic version. The JA-103K-7AH has a larger enclosure and battery, so the system lasts longer without mains power and tolerates a higher peripheral consumption. The JA-103KR is supplied with a radio module, so you can enrol wireless peripherals with no further purchase. If the installation needs more than 50 peripherals or 8 sections, choose the JA-107K or JA-108K.
- Covers a family home or a smaller business. The system supports 50 peripherals, 50 users, 8 sections and 32 programmable outputs.
- Bus and wireless peripherals on one control unit. The bus runs from one terminal block, wireless devices are handled by the JA-11xR radio module and the LAN communicator is factory-fitted.
- The system keeps running even during a power failure. The 12 V / 2.6 Ah back-up battery maintains operation according to the total consumption of the fitted peripherals.
- Configure it with the same tool as the rest of the platform. Configuration is done in the F-Link software, version 2.0.0 or later.
Why choose this product
How large an installation the control unit covers
JA-103 control units are designed for installations that one bus can cover: a family home, office, shop or smaller business. The capacity is fixed and cannot be extended, so allow for spare capacity at the design stage.
- Up to 50 peripherals and 50 users
- 8 separate sections
- 32 programmable outputs (PG)
What you can connect to the control unit
Bus devices are connected by a single cable and need no batteries; wireless devices suit places where you cannot chase into walls. The control unit handles both at the same time and sends notifications to the Alarm Receiving Centre over the LAN; a project adds the mobile path when it needs a second independent route.
- Bus peripherals connect to one BUS terminal block
- Wireless peripherals require a JA-11xR radio module; up to 3 can be fitted
- The LAN communicator is part of the board; a mobile communicator is fitted into a dedicated connector
Power supply, backup and classification
How long the system runs without mains power depends on the capacity of the rechargeable battery and on how many devices are installed in the system. Calculate this when designing the installation, not when commissioning the system.
- Recommended back-up battery 12 V / 2.6 Ah, lead-acid gel
- 24-hour backup with a peripheral consumption of up to 26 mA, without a mobile communicator and with the LAN switched off
- Security grade 2, environmental class II
Frequently asked questions
No. Only the Ethernet 10/100 BASE LAN communicator is factory-fitted. The JA-192Y, JA-194Y or JA-194Y-LITE mobile communicator is purchased separately and fitted into a dedicated connector.
Technical specifications
- Control panel power supply
- ~ 110 – 230 V/50 – 60 Hz, max. 0.28 A with fuse F1.6 A/250 V, Protection class II
- Back-up battery
- 12 V; 2.6 Ah (lead gel)
- Maximum battery charging time
- 48 h
- BUS voltage (red - black)
- 12.0 to 13.8 V
- Maximum continuous current consumption from the control panel
- 1000 mA
- Max. continuous current consumption for back-up 12 hours
- Without GSM communicator, LAN – OFF: 115 mA LAN – ON: 88 mA
- Max. continuous current consumption for back-up 24 hours
- Without GSM communicator, LAN – OFF: 21 mA
- Maximum number of devices
- 50
- LAN communicator
- Ethernet interface, 10/100BASE
- Dimensions
- 268 x 225 x 83 mm
- Weight with/without AKU
- 1844 g/970 g
- Reaction to invalid code entry
- Alarm after 10 wrong code entries
- Event memory
- Approx. 7 million latest events, including date and time
- Power supply unit
- Type A according to EN 50131-6 T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC.
- GSM communicator (2G)
- 850 / 900 / 1800 / 1900 MHz
- Classification
- Security grade 2 according to EN 50131-1
- Operational environment
- Environmental class II (indoor general) according to EN 50131-1
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581
- Radio operating frequency (with the JA 11xR module)
- 868.1 MHz
- Radio emissions
- ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
- EMC
- EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7
- Safety conformity
- EN 62368-1+A11
- Caller identification (CLIP)
- ETSI EN 300 089
- Operational conditions
- ERC REC 70-03
- Certification body
- Trezor Test s.r.o. (no. 3025)
Warning
- Always connect the bus with the system power completely switched off. The onboard I-BUS is reserved for the JA-11xR radio module. Do not connect ordinary peripherals to it; they belong on the BUS terminal block.
- With the LAN switched on, this configuration does not achieve the 24-hour backup.
- The battery takes up to 48 hours to charge to 80% of capacity. Immediately after commissioning, the backup is therefore not yet fully available.
- The microSD card is factory-fitted in the control unit and the control unit does not work properly without it. When replacing it with a brand-new card, reset the control unit to factory settings and then update the firmware so that the necessary system files are loaded onto the card.
Installation example
The control unit may only be installed by a trained technician holding a valid JABLOTRON certificate.
Fix the enclosure to a vertical surface in an indoor environment.
Bring in the mains supply and provide the prescribed protection of the supply line according to the technical documentation.
Run the bus from one terminal block and connect the bus peripherals.
If the installation includes wireless devices, fit a JA-11xR radio module on the onboard I-BUS.
If the system is also to report over the mobile network, fit a mobile communicator into the dedicated connector.
Connect the 12 V / 2.6 Ah back-up battery.
Check that a microSD card is inserted in the holder on the control unit board (factory-fitted).
Configure the control unit in F-Link: system capacity, sections, users and programmable outputs.
Check that the total consumption of the peripherals matches the required standby time.
Related products

JA-107K
Control panel JA-107K

JA-108K
Control panel JA-108K

JA-111R
Bus interface for JA-100 wireless devices

JA-103KR
Control panel JA-103KR

JA-103K-7AH
Control panel JA-103K-7AH

JA-107KR
Control panel JA-107KR

JA-121T
RS-485 bus interface

JA-112R
Bus module for connecting JA-100 wireless components

JA-194Y
LTE communicator module

JA-194Y-LITE
LTE communicator module

JA-190X
Telephone communicator module

JA-191Y
LTE communicator module
Help us improve the catalog