JA-190X
Telephone communicator module
Telephone communicator module for the control unit, connected to an analogue telephone line. It reports alarms to the Alarm Receiving Centre using a digital protocol and delivers voice alarm messages to set telephone numbers. It is installed by a trained technician.
Compatibility
JA-100K, JA-101K, JA-106K
Check compatibilityKey specifications
- Dialling method
- DTMF
- Phone line check
- optional – enabled / disabled
- Voice message phone numbers with JA-101K
- 8
- Voice message phone numbers with JA-106K
- 15
- Classification
- Security grade 2/environmental class II
- - according to
- EN 50131-1, EN 50131-3, EN 50131-10, EN 50136-1, EN 50136-2, SIA DC-02, SIA DC-05
- - average humidity
- 75 % RH, non condensation
Basic description
With this pair, a single question decides: stay with the telephone line or move to the mobile network. Both modules play the same role in the control unit: they connect it to the Alarm Receiving Centre, deliver voice alarm messages and are configured in the F-Link software. The JA-191Y also sends alarm SMS messages and allows the system to be configured remotely.
- Reports alarms to the Alarm Receiving Centre and delivers voice alarm messages; the communicator is configured in the F-Link software.
- Connects to an analogue telephone line and dials using DTMF tone dialling.
- The number of telephone numbers for voice alarm messages depends on the type of control unit.
- Complies with security grade 2 and environmental class II according to EN 50131-1.
Why choose this product
What the module reports and how
The module reports alarms to the Alarm Receiving Centre using a digital protocol over the telephone line, delivers voice alarm messages to set telephone numbers and provides voice remote access to the control unit.
- Digital transmission using the ADM-CID (DTMF) and SIA-DCS (FSK) protocols.
- A voice alarm message consists of four parts: an introductory message, the type of notification, the section number and its name.
- It checks the status of the telephone line and reports a fault after 30 minutes; if this check is disabled, the system does not meet the requirements of EN 50131-1.
What the control unit needs
The communicator is configured in the F-Link software on the Communication tab; transmissions to the Alarm Receiving Centre are configured on the ARC tab.
- Plugs into the dedicated connector on the main board of the JA-10xK control unit.
- The daily limit for outgoing calls can be set from 5 to 500 minutes; the factory default is 20 minutes.
- The module is disabled in F-Link by default; the installation technician enables it.
Where it is mounted and what it needs
It is connected into the telephone line, which passes through it on to the downstream telephone sets; during a call, the line is disconnected from them.
- Input terminals INa and INb, output terminals OUTa and OUTb for the downstream telephone sets.
- The telephone line input is protected by basic overvoltage protection.
Frequently asked questions
You stay with the analogue telephone line; this communicator works only with it.
Check this in the compatibility overview on the website; it will confirm which control units this module works with.
Technical specifications
- Dialling method
- DTMF
- Phone line check
- optional – enabled / disabled
- Voice message phone numbers with JA-101K
- 8
- Voice message phone numbers with JA-106K
- 15
- Classification
- Security grade 2/environmental class II
- - according to
- EN 50131-1, EN 50131-3, EN 50131-10, EN 50136-1, EN 50136-2, SIA DC-02, SIA DC-05
- - average humidity
- 75 % RH, non condensation
- - alarm transmission class – voice
- ATS 2
- - alarm transmission class – digital
- ATS 4
- - digital data protocols
- ADM-CID (DTMF), SIA-DCS (FSK)
- Weight
- 28 g
- Analogue interface connectivity according to
- EN 301 437,TBR 21
- Also complies with
- EN 50130-4, EN 55022, EN 60950-1
Warning
- The option for a non-standard analogue line, such as a radio transmitter, lowers the fault threshold to a voltage below 10 V; with a standard telephone line, leave it disabled.
Installation example
Before installation, switch off the control unit's power supply completely.
Plug the module into the dedicated connector on the control unit board.
Connect the telephone line to the INa and INb input terminals; connect the downstream telephone sets to the OUTa and OUTb output terminals.
If the line carries ADSL, connect the module after the splitter as the first device on the line, before the other telephone sets.
If the telephone line runs on poles and there is a risk of electromagnetic interference, connect earthing to the unmarked earth terminal.
Switch on the power and complete the settings in the F-Link software on the Communication tab.
Related products

JA-103K
Control panel JA-103K

JA-107K
Control panel JA-107K

JA-108K
Control panel JA-108K

JA-111R
Bus interface for JA-100 wireless devices

JA-103KR
Control panel JA-103KR

JA-103K-7AH
Control panel JA-103K-7AH

JA-107KR
Control panel JA-107KR

JA-194Y
LTE communicator module

JA-194Y-LITE
LTE communicator module

JA-121T
RS-485 bus interface

JA-112R
Bus module for connecting JA-100 wireless components

JA-191Y
LTE communicator module
Help us improve the catalog
Missing something, or found a mistake? Let us know.