JA-190X

Telephone communicator module

Telephone communicator module for the control unit, connected to an analogue telephone line. It reports alarms to the Alarm Receiving Centre using a digital protocol and delivers voice alarm messages to set telephone numbers. It is installed by a trained technician.

Compatibility

JA-100K, JA-101K, JA-106K

Check compatibility

Key specifications

Dialling method
DTMF
Phone line check
optional – enabled / disabled
Voice message phone numbers with JA-101K
8
Voice message phone numbers with JA-106K
15
Classification
Security grade 2/environmental class II
- according to
EN 50131-1, EN 50131-3, EN 50131-10, EN 50136-1, EN 50136-2, SIA DC-02, SIA DC-05
- average humidity
75 % RH, non condensation

Basic description

With this pair, a single question decides: stay with the telephone line or move to the mobile network. Both modules play the same role in the control unit: they connect it to the Alarm Receiving Centre, deliver voice alarm messages and are configured in the F-Link software. The JA-191Y also sends alarm SMS messages and allows the system to be configured remotely.

  • Reports alarms to the Alarm Receiving Centre and delivers voice alarm messages; the communicator is configured in the F-Link software.
  • Connects to an analogue telephone line and dials using DTMF tone dialling.
  • The number of telephone numbers for voice alarm messages depends on the type of control unit.
  • Complies with security grade 2 and environmental class II according to EN 50131-1.

Why choose this product

What the module reports and how

The module reports alarms to the Alarm Receiving Centre using a digital protocol over the telephone line, delivers voice alarm messages to set telephone numbers and provides voice remote access to the control unit.

  • Digital transmission using the ADM-CID (DTMF) and SIA-DCS (FSK) protocols.
  • A voice alarm message consists of four parts: an introductory message, the type of notification, the section number and its name.
  • It checks the status of the telephone line and reports a fault after 30 minutes; if this check is disabled, the system does not meet the requirements of EN 50131-1.

What the control unit needs

The communicator is configured in the F-Link software on the Communication tab; transmissions to the Alarm Receiving Centre are configured on the ARC tab.

  • Plugs into the dedicated connector on the main board of the JA-10xK control unit.
  • The daily limit for outgoing calls can be set from 5 to 500 minutes; the factory default is 20 minutes.
  • The module is disabled in F-Link by default; the installation technician enables it.

Where it is mounted and what it needs

It is connected into the telephone line, which passes through it on to the downstream telephone sets; during a call, the line is disconnected from them.

  • Input terminals INa and INb, output terminals OUTa and OUTb for the downstream telephone sets.
  • The telephone line input is protected by basic overvoltage protection.