JA-107KR

Control panel JA-107KR

JABLOTRON 100+ system control unit for large flats, offices, companies and commercial premises. Peripherals are split between two BUS terminal blocks and into separate sections. The JA-107KR is supplied with a JA-11xR radio module.

Product line

  • JABLOTRON 100+

Key specifications

Number of sections
15
Maximum number of devices
230
Max. number of PG outputs
128
Maximum number of users
600
Maximum continuous current consumption from the control panel
2000 mA permanent 3000 mA for 60 minutes (max. 2000 mA for one BUS)
Back-up battery
12 V; 7 to 18 Ah (lead gel)
Classification
Security grade 2 according to EN 50131-1
Dimensions
357 x 297 x 105 mm

Basic description

The JA-107K, JA-107KR and JA-108K control units have the same system capacity, the same bus and the same enclosure. The JA-107K is the basic version. The JA-107KR is supplied with a radio module, so you can enrol wireless peripherals with no further purchase. The JA-108K is the only one that supports the security profile for Security Grade 3, i.e. premises with a higher level of risk; in this profile, however, it works only with bus peripherals. For smaller installations, choose the JA-103 range.

  • Covers a large building or an entire company. The system supports 230 peripherals, 600 users, 15 sections and 128 programmable outputs.
  • Bus and wireless peripherals on one control unit. Peripherals are split between two BUS terminal blocks, wireless devices are handled by the JA-11xR radio module and the LAN communicator is factory-fitted.
  • Enrol wireless peripherals straight after installation. The JA-11xR radio module is factory-fitted and does not need to be purchased.
  • Configure it with the same tool as the rest of the platform. Configuration is done in the F-Link software.

Why choose this product

How large an installation the control unit covers

The JA-107 and JA-108 control units are designed for installations where one bus branch is not enough: large flats, offices, companies and commercial premises. Splitting the peripherals between two branches keeps the wiring clear even in a large building.

  • Up to 230 peripherals and 600 users
  • 15 separate sections
  • 128 programmable outputs (PG)

What you can connect to the control unit

Bus devices are connected by a single cable and need no batteries; wireless devices suit places where you cannot chase into walls. The control unit sends notifications to the Alarm Receiving Centre over the LAN; a project adds the mobile path when it needs a second independent route.

  • Bus peripherals are split between two mutually isolated terminal blocks, up to 60 on each
  • The JA-11xR radio module is factory-fitted; up to 3 can be fitted
  • The LAN communicator is part of the board; a mobile communicator is fitted into a dedicated connector

Power supply, backup and classification

How long the system runs without mains power depends on the capacity of the rechargeable battery and on how many devices are installed in the system. Calculate this when designing the installation, not when commissioning the system.

  • Recommended back-up battery 12 V / 18 Ah, lead-acid gel
  • 24-hour backup with a peripheral consumption of up to 535 mA, without a mobile communicator and with the LAN switched off
  • Security grade 2, environmental class II