JA-108K
Control panel JA-108K
JABLOTRON 100+ system control unit for large flats, offices, companies and commercial premises. Peripherals are split between two BUS terminal blocks and into separate sections. The JA-108K is the only one in the range that supports the security profile for Security Grade 3.
Product line
- JABLOTRON 100+
Key specifications
- Number of sections
- up to 15
- Max. number of PG outputs
- 128
- Maximum number of users
- 600
- Dimensions
- 357 × 297 × 105 mm
Basic description
The JA-107K, JA-107KR and JA-108K control units have the same system capacity, the same bus and the same enclosure. The JA-107K is the basic version. The JA-107KR is supplied with a radio module, so you can enrol wireless peripherals with no further purchase. The JA-108K is the only one that supports the security profile for Security Grade 3, i.e. premises with a higher level of risk; in this profile, however, it works only with bus peripherals. For smaller installations, choose the JA-103 range.
- Covers a large building or an entire company. The system supports 230 peripherals, 600 users, 15 sections and 128 programmable outputs.
- Bus and wireless peripherals on one control unit. Peripherals are split between two BUS terminal blocks, wireless devices are handled by the JA-11xR radio module and the LAN communicator is factory-fitted.
- Protect even premises with a higher level of risk. The security profile in F-Link switches the system to Security Grade 3; in this profile it works only with bus peripherals.
- Configure it with the same tool as the rest of the platform. Configuration is done in the F-Link software.
Why choose this product
How large an installation the control unit covers
The JA-107 and JA-108 control units are designed for installations where one bus branch is not enough: large flats, offices, companies and commercial premises. Splitting the peripherals between two branches keeps the wiring clear even in a large building.
- Up to 230 peripherals and 600 users
- 15 separate sections
- 128 programmable outputs (PG)
What you can connect to the control unit
Bus devices are connected by a single cable and need no batteries; wireless devices suit places where you cannot chase into walls. The control unit sends notifications to the Alarm Receiving Centre over the LAN; a project adds the mobile path when it needs a second independent route.
- Bus peripherals are split between two independent terminal blocks, up to 60 on each
- JA-11xR radio module only in the profile for Security Grade 2; up to 3 can be fitted
- The LAN communicator is part of the board; a mobile communicator is fitted into a dedicated connector
Power supply, backup and classification
How long the system runs without mains power depends on the capacity of the rechargeable battery and on how many devices are installed in the system. Calculate this when designing the installation, not when commissioning the system.
- Recommended back-up battery 12 V / 18 Ah, lead-acid gel
- 24-hour backup with a peripheral consumption of up to 535 mA, without a mobile communicator and with the LAN switched off
- Security Grade 3 only in the profile without radio modules, otherwise Grade 2; environmental class II
Frequently asked questions
No. Only the Ethernet 10/100 BASE LAN communicator is factory-fitted. The mobile communicator is purchased separately as a JA-19xY module, i.e. JA-194Y or JA-194Y-LITE.
Technical specifications
- Primary security profile
- Grade 3
- Other operating profiles
- Grade 2 and Default (JABLOTRON)
- Standards
- EN 50131-3, EN 50131-6, EN 50131-10, EN 50130-4, EN 55032, EN 62368-1, EN 50136-1, EN 50136-2
- Environmental class
- II – indoor general
- Number of peripherals
- up to 230, of which up to 120 wireless
- Number of users
- up to 600
- Number of sections
- up to 15
- Number of PG outputs
- up to 128, wirelessly PG 1–32
- LAN communicator
- integrated Ethernet 10/100BASE
- GSM/LTE communication
- via the optional JA-19xY module
- ATS classification
- SP5 with LAN or GSM, DP3 with LAN + GSM
- ARC/CMS protocols
- Jablo IP, ANSI SIA DC-09
- Power supply
- 110–230 V AC, 50–60 Hz
- BUS output
- 12.0–13.8 V DC, max. 2000 mA continuous
- Short-term BUS current
- max. 3000 mA for 60 min
- Bus
- BUS 1, BUS 2, BUS 3 / I-BUS
- Bus length
- up to 3 × 500 m
- Battery
- 12 V / 18 Ah, lead-acid gel
- Backup
- up to 60 h depending on system load
- Dimensions
- 357 × 297 × 105 mm
- Operating temperature
- −10 °C to +40 °C
- Event memory
- approx. 7 million events
Warning
- Always connect the bus with the system power completely switched off. No wireless peripherals can be used in the profile for Security Grade 3. The maximum number of JA-11xR radio modules in this profile is zero and the system works only via the bus.
- Blocking of user inputs after 10 incorrectly entered codes applies in the profile for Security Grade 3. In the other profiles, the control unit does not block the inputs.
- Always connect the bus with the system power completely switched off. No more than 60 peripherals belong on one BUS terminal block. The total system capacity does not mean they can all be connected to one branch.
- Only programmable outputs PG 1 to 32 can be controlled wirelessly. The other outputs are available only via the bus.
- The battery takes up to 48 hours to charge to 80% of capacity. Immediately after commissioning, the backup is therefore not yet fully available.
- The microSD card is factory-fitted in the control unit and the control unit does not work properly without it. When replacing it with a brand-new card, reset the control unit to factory settings and then update the firmware so that the necessary system files are loaded onto the card.
Installation example
The control unit may only be installed by a trained technician holding a valid JABLOTRON certificate.
Fix the enclosure to a vertical surface in an indoor environment.
Bring in the mains supply and provide the prescribed protection of the supply line according to the technical documentation.
Run both bus branches and split the peripherals between the two terminal blocks.
In F-Link, select the security profile: Security Grade 3, Grade 2, or the JABLOTRON default settings.
Fit the JA-11xR radio module on the onboard I-BUS only in the profile for Grade 2; in the profile for Grade 3, the control unit does not allow any module.
If the system is also to report over the mobile network, fit a mobile communicator into the dedicated connector.
Connect the 12 V / 18 Ah back-up battery.
Check that a microSD card is inserted in the holder on the control unit board (factory-fitted).
Complete the configuration in F-Link: system capacity, sections, users and programmable outputs.
Check that the total consumption of the peripherals matches the required standby time.
Related products

JA-103K
Control panel JA-103K

JA-107K
Control panel JA-107K

JA-111R
Bus interface for JA-100 wireless devices

JA-103KR
Control panel JA-103KR

JA-103K-7AH
Control panel JA-103K-7AH

JA-107KR
Control panel JA-107KR

JA-121T
RS-485 bus interface

JA-116E
Bus touchscreen keypad with RFID reader

JA-113M
Bus magnetic detector with recognition of external magnetic fields

JA-113M-AN
Bus magnetic detector with recognition of external magnetic fields - anthracite

JA-113M-GR
Bus magnetic detector with recognition of external magnetic fields - grey

JA-116E-AN
Bus touchscreen keypad with RFID reader - anthracite
Help us improve the catalog
Missing something, or found a mistake? Let us know.