JA-115E-GR
Bus four-segment keypad with display and RFID reader - grey
Physical buttons tailored to the particular premises. Traffic-light logic for quick, clear everyday control, a display and a menu for advanced functions, authorisation by code as well as by a 125 kHz tag.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Current consumption in standby mode
- 18 mA
- Current consumption for cable selection
- 150 mA
- RFID frequency
- 125 kHz
- Dimensions
- 110 x 136 x 33 mm
Basic description
Revolutionary simplicity of alarm control that even children can manage. The left green button unsets, the right red button sets. Besides that, the buttons can also control functions such as doors, lighting and other appliances.
- To unset, press the green button and enter a code or present a tag. Setting is possible without authorisation too; just press the red button and leave.
- 4 fixed segments cover the most-used functions, clearly and with one press
- The display and the menu show details of events and make it possible to set up users and to block detectors
Why choose this product
Simple authorisation
After pressing a segment, it is enough to enter a numeric code or present a tag once. From that, the system distinguishes who is operating it and whether they have the authorisation needed.
- Authorisation is always required for unsetting
- For setting or PG control, mandatory authorisation is optional, separately for each segment
- On arrival, control by authorisation alone is possible; just present a tag and the section concerned is unset automatically
Easy installation
Unlike the modular construction of JA-114E, the 4 segments are a fixed part of the keypad and their number cannot be extended. The keypad covers the most common range while installation is markedly simpler.
- Each segment can be configured entirely individually
- The functions used most often are assigned to the segments; the rest can be controlled in the menu
- No assembling of segments and no printing of labels
Choosing the right type of keypad
A broad portfolio of keypads meets different control needs. From the main entrance through a floor or a garage to a gate or a delivery entrance.
- The main keypad of the system should always have a display for full control; choose from the JA-1x4E, JA-1x5E or JA-1x6E
- A secondary keypad on a floor or in a garage can be without a display; choose from the JA-1x3E, JA-121E or JA-123E
- For a single-purpose function such as passing through a door or opening a gate, a reader may be enough; choose from the JA-1x2E, JA-120E or JA-122E
Frequently asked questions
In its fixed construction. JA-115E has four segments permanently and cannot be extended, while JA-114E is built from JA-192E segments into an assembly of up to 20 segments. On JA-115E you set the segment labels in software in F-Link and they appear on the display; on JA-114E they are printed and inserted into the segment covers.
The reader frequency. JA-115E reads identifiers at 125 kHz, JA-115E-NFC works at 13.56 MHz, and older identifiers for 125 kHz do not work at that frequency. Mechanically and in their dimensions the two keypads are identical; the NFC version has a lower consumption from the bus.
Four segments are not the same as four sections. Thanks to the Common segment function, one segment can control several sections, while another may only indicate a state. At most one common segment can be configured on one keypad. The labels on the display state clearly what each segment does, and the installation company can change them without replacing any stickers.
Technical specifications
- Type of control device
- B
- Power
- from control panel bus 12 V DC (8–15 V)
- Current consumption in standby mode
- 18 mA
- Current consumption for cable selection
- 150 mA
- RFID frequency
- 125 kHz
- Maximum RFID magnetic field strength
- -5.4 dBµA/m (measured at 10 m)
- Dimensions
- 110 x 136 x 33 mm
- Weight
- 285 g
- Classification
- Security grade 2/Environmental class II according to EN 50131-1
- Environment
- indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75% RH, w/o condensation
- Certification body
- Trezor Test s.r.o. (nr. 3025)
- In compliance with
- ETSI EN 300 330, EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000, EN 50131-1, EN 50131-3
- Can be operated according to
- ERC REC 70-03
- Recommended screw
- 4 x o 3.5 x 40 mm (half-round head)
Warning
- The keypad has four fixed segments and cannot be extended with further segments, unlike the JA-113E and JA-114E access modules. At most one common segment can be configured on one keypad, and combining it with the Section and Common to sections functions is not suitable. Do not apply the Authorisation unsets the section with an entry delay in progress option to a Common section; it may lead to all the sections assigned, or the whole system, being unset undesirably. The Permanently on option for the RFID reader does not respect the waking settings and permanently increases the consumption from the bus. Segments do not signal in Service mode or with the None function. The economical sleep mode with limited fault and alarm memory indication is only active with the EN 50131-1 and Incert profiles, and the Silence option is only available in NIGHT mode. For sizing the back-up, allow for 18 mA; for choosing the cable, allow for the maximum consumption of 100 mA. Security grade 2 applies only when the corresponding configuration scheme is selected in F-Link on the Parameters tab. Only stripped, straight conductors belong in the screwless terminal block; do not bend them into a loop or a hook. Connect the bus only with the system power supply completely switched off. The keypad is intended only for the indoor – general environment, −10 to +40 °C and 75% RH non-condensing. Verify the number of device positions taken up in the control unit documentation. Installation may only be carried out by a trained technician with a valid JABLOTRON certificate.
Installation example
Always connect the bus with the system power supply completely switched off.
Take off the back plate of the keypad.
In the back plate, break out the appropriate knock-out opening, pull the bus cable through and screw the back plate to the surface with four Ø 3.5 × 40 mm screws with a round head.
Connect the conductors to the terminal block: +U red as the positive pole of the power supply, A yellow as data conductor A, B green as data conductor B and GND black as the negative pole. Insert the conductors stripped and straight; do not bend them into a loop or a hook.
Verify the firmness of every joint by pulling gently on the conductor.
Place the keypad with its bottom edge on the back plate and slide it down until the latch clicks.
Turn the locking mechanism through 90° clockwise; the keypad is fixed in place and the tamper contacts close.
Switch on the system power supply and enrol the keypad using the recommended software or app for the type of control unit, or by entering the full serial number below the bar code.
In F-Link, on the Devices tab, set the segment functions, the labels, the RFID reader mode, the brightness for DAY and NIGHT and the acoustic signalling.
For a certified deployment, select the corresponding configuration scheme in F-Link on the Parameters tab.
Related products

JA-112E
Bus RFID Access Module

JA-113E
Bus Access Module with keypad and RFID

JA-114E
Bus Access Module with display, keypad and RFID

JA-116E
Bus touchscreen keypad with RFID reader

JA-115E
Bus four-segment keypad with display and RFID reader

JA-110E
Bus keypad

JA-120E-WH
Bus outdoor RFID / NFC reader - white

JA-120E-BK
Bus outdoor RFID / NFC reader - black

JA-121E-WH
Bus outdoor keypad with RFID / NFC reader - white

JA-121E-BK
Bus outdoor keypad with RFID / NFC reader - black

JA-122E-NFC
Bus outdoor RFID reader 13.56 MHz

JA-123E-NFC
Bus outdoor keypad with RFID reader 13.56 Mhz
Help us improve the catalog
Missing something, or found a mistake? Let us know.