JA-115P
Bus ceiling PIR motion detector
A ceiling PIR movement detector with 360° coverage, part of the JABLOTRON 100+ system. It monitors the room from above, so it reduces dead angles behind furniture and cupboards. It is powered via the bus, with no batteries.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Power
- from the control panel BUS 12 V DC (9 ... 15 V)
- - nominal consumption to calculate backup time
- 2.8 mA
- - maximum consumption for cable selection
- 30 mA
- Recommended installation height
- 2.5 – 3.5 m above ground level
- Detection coverage
- 360 °/11 m (installation height – 3.5 m)
- Dimensions
- O 125 x 40 mm
- Weight
- 120 g
Basic description
The ceiling version is suitable where a wall-mounted detector has no suitable corner, or where furniture and partitions create dead zones. The detection range is the same for both versions; what differs is the connection: the bus version is powered via a single cable and needs no batteries, the wireless version requires no cable to the ceiling and needs a JA-11xR radio module in the control unit. The wireless version therefore usually wins in refurbishments and in suspended ceilings.
- One detector covers the room beneath it. Ceiling mounting reduces the dead angles that a wall-mounted detector is left with behind furniture.
- Powered from the bus. No batteries and no battery replacement throughout the detector's service life.
- 360° coverage over the whole area beneath the detector. The coverage radius increases with the installation height.
- Security grade 2 and environmental class II. Suitable for commercial and residential installations.
Why choose this product
What the detector covers
The detector monitors the area beneath it through the full angle, so it covers even a room with an irregular floor plan. The lens is fixed and cannot be replaced, so you tune the coverage only by choosing the place and height.
- 360° coverage over the whole area beneath the detector
- Recommended installation height 2.5 to 3.5 m
- Coverage radius up to 5.5 m when installed at 3.5 m
Immunity to false alarms
The detector distinguishes the real movement of a warm body from a brief temperature fluctuation. A higher immunity level reduces the number of false alarms, but the reaction is slower, so choose it according to what normally goes on in the room.
- Pulse evaluation of movement
- Two immunity levels, set in F-Link
- The tamper contact reports opening of the cover
How the detector is connected
Unattended operation with no need for regular service visits is an advantage especially in exposed places by entrances and staircases, where every visit by a technician would mean a call-out.
- Power and communication via the bus, 12 V
- No batteries and no battery replacement
- Connects to the control unit's BUS terminal block
Frequently asked questions
When there is no suitable corner, or when furniture and partitions leave dead zones. Ceiling mounting monitors the area from above, so it is suitable for open-plan offices, receptions, corridors without a corner and rooms with an irregular floor plan.
Most often the view is to blame. With a ceiling detector, check whether a chandelier, a fan or a ceiling air-conditioning outlet reaches into its field of view. If the view is clear, switch the detector to the higher immunity level.
The recommended height is 2.5 to 3.5 m. Above 3.5 m the sensitivity directly beneath the detector drops, so for higher ceilings consider combining several detectors.
Technical specifications
- Power
- from the control panel BUS 12 V DC (9 ... 15 V)
- - nominal consumption to calculate backup time
- 2.8 mA
- - maximum consumption for cable selection
- 30 mA
- Recommended installation height
- 2.5 – 3.5 m above ground level
- Detection coverage
- 360 °/11 m (installation height – 3.5 m)
- Dimensions
- O 125 x 40 mm
- Weight
- 120 g
- Classification
- security grade 2/environmental class II (according to EN 50131-1)
- Operational environment
- indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-2-2, EN 50130-4 ed. 2+A1, EN 55032, EN 50581
Warning
- Above 3.5 m the sensitivity directly beneath the detector drops.
- There must be no obstacles in the field of view that block the view, typically a chandelier, a fan or an air-conditioning outlet.
- The detector can only be fitted on the base in one position, according to the alignment arrows.
- After installation, and whenever the lens or the height is changed, verify the coverage with a walk test. The actual range in the room differs from the figure in the table depending on what is in the way.
Installation example
Always connect the bus with the system power completely switched off.
Choose a place on the ceiling at a height of 2.5 to 3.5 m, with a clear view of the area.
Open the detector by turning the top part to the left.
Pass the bus cable through the cut-out and screw the base to the ceiling.
Slide out the terminal block and connect the cable according to the colour coding.
Enrol the detector according to the control unit manual.
Put the detector back on the base according to the alignment arrows, and secure it by turning it to the right and with the locking screw.
Accessories
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector

JA-113M
Bus magnetic detector with recognition of external magnetic fields
Help us improve the catalog
Missing something, or found a mistake? Let us know.