JB-110N
Bus PG power output module
A universal power relay for a box or a control unit. An open NO / NC contact for switching loads of up to 16 A.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption (relay off/on)
- 5 mA/45 mA
- Current consumption for cable selection
- 45 mA
- - Maximum switched voltage
- 250 V AC
- - Maximum current - resistive load (cos φ=1)
- 16 A
- - Maximum current - inductive (capacitive) load (cos φ=0.4)
- 8 A
- - Minimum acceptable relay output through-wattage (DC)
- 0.5 W
Basic description
The module copies the programmable outputs assigned from the control unit. It is installed directly in the control unit or in the JA-190PL, JA-194PL or JA-195PL universal boxes. It switches the power supply or the control of appliances such as lighting, electric heating, a pump and similar.
- It takes up no position in the system. The output copied is set with the switches directly on the module
- Powered directly from the bus; it needs no separate power supply
Why choose this product
Load capacity for particular appliances
The contact handles an alternating voltage of up to 250 V and a direct voltage of up to 24 V. The maximum current load is determined by the character of the load.
- Purely resistive load (heating, water heater and so on) up to 16 A, halogen lighting with a power of 1,000 W at most
- Inductive and capacitive load (pumps, switched-mode power supplies, conventional fluorescent lights) up to 6 A
- DC maximum switched power 384 W, minimum 0.5 W
Frequently asked questions
It does not. It is not addressable and is not enrolled into the control unit; once the switch has been set, it works without any record in the system. The number of modules is limited only by the total current drawn from the control unit.
In the load capacity. JB-110N is a power version: it switches appliances powered from the mains, typically lighting or a fan. JB-111N is a signal version, for extra-low-voltage circuits, for example an electric door lock.
Only in a JA-194PL or JA-195PL box together with the JA-111H TRB tamper protection module. In that assembly the module is classified as security grade 2 and environmental class II; in any other arrangement, grade 2 cannot be relied on.
Technical specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption (relay off/on)
- 5 mA/45 mA
- Current consumption for cable selection
- 45 mA
- - Maximum switched voltage
- 250 V AC
- - Maximum current - resistive load (cos φ=1)
- 16 A
- - Maximum current - inductive (capacitive) load (cos φ=0.4)
- 8 A
- - Minimum acceptable relay output through-wattage (DC)
- 0.5 W
- Protection
- Class II
- Dimensions
- 78 x 40 x 20 mm
- Weight
- 34 g
- Classification
- Security grade 2/Environmental class II (according to EN 50131-1) Only when installed into the JA-194PL or JA-195PL mounting box together with the JA-111H TRB module!
- Operational environment
- indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 62368-1, EN 50581
Warning
- Always connect the bus with the system power supply completely switched off, and leave the connection of mains devices to a qualified person. The module must not be left lying loose: outside a mounting box or the control unit enclosure, neither protection class II nor the manufacturer's responsibility applies. Outside the prescribed assembly with the box and the tamper module, security grade 2 cannot be relied on. If the voltage on the bus drops below the prescribed limit while the relay is switched on, reliable switching is not guaranteed. The number of modules in the system is limited by the total current drawn from the control unit. Operation is limited to the indoor – general environment, −10 to +40 °C and 75% RH non-condensing. If the module is outside the protected space, separate the bus feed with a JA-110T isolator.
Installation example
Always connect the bus with the system power completely switched off. Mains devices may only be connected by a qualified person.
Using the configuration switch, set the number of the programmable output or section the relay is to respond to, according to the tables.
Connect the bus cable to the BUS terminal block.
Fix the module in the lower part of the JA-19xPL box to the spacer posts using the mounting material supplied, or place it in the control unit enclosure.
Switch the system on and test the function.
Check that the supply voltage at the bus terminals (red, black) is greater than 9 V while the relay is switched on.
Connect the appliance to be switched to the relay terminal block.
Related products

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector

JA-113M
Bus magnetic detector with recognition of external magnetic fields