JA-112P
Bus PIR motion detector
A design version for modern interiors. 90° coverage angle, 12 m range. High immunity to false alarms and maintenance-free operation thanks to power from the bus.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Compatible with
- F-Link 2.0.0 and higher
- Power
- from the control panel BUS 12 V (9 ... 15 V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice (maximum)
- 16 mA
- Recommended installation height
- 2.5 m above the floor
- Detection angle / detection range
- 90 °/12 m
- Dimensions
- 62 x 110 x 40 mm
Basic description
The passive infrared detector not only detects an intruder, it also serves for lighting automation and other scenarios. Its clean design and several colour versions make it a natural choice for prestigious spaces.
- Advanced analysis of the signal from the PIR sensor minimises false alarms
- Adjustable sensitivity
- Fan-shaped detection pattern, optional grey JS-7920 lens with above-standard immunity to white light
- Combined versions with a camera, glass-break detection or microwave detection are available in the same design range
Why choose this product
How the detector works
It responds to changes in the thermal image within its field of view. It is triggered when it sees the movement of a larger body at a temperature close to that of a human. It is suitable for ordinary interiors where no sharp temperature fluctuations occur. If interfering stimuli appear in the space, the immunity can be increased remotely.
- Covers a room of ordinary size
- Typically mounted in a corner, but also on a flat wall at a height of 2.2 to 2.5 m
One detector, plenty of functions
Besides detecting an uninvited guest, the detector can also be used for comfort functions while the system is unset. No additional sensors are needed. An alarm detector is ideal for automating lighting or other appliances as well.
- Lights switched on automatically on movement after dark, and switched off automatically in a room where nobody has moved for a longer time
- Economical switching of hot water circulation based on movement in the hallway or the kitchen
- Movement information passed on to the smart home
Positioning rules
A few basic rules need to be kept in mind for PIR detectors to work reliably. Given the detector's operating principle, unsuitable positioning may cause false alarms or insufficient coverage of the room.
- Keep to the mounting height recommended for the particular type of detector. Detectors with PET immunity, for example, are installed lower than ordinary PIRs
- Avoid positions above heating, above a window or close to air conditioning ducts, where sharp temperature fluctuations are a risk
- In problematic rooms, use the version combined with microwave detection, which is immune to temperature influences
Frequently asked questions
In the cover and the coverage angle. This detector has a narrower cover 40 mm deep and a fixed lens with a 90° coverage angle; the standard version has a deeper cover, a 110° coverage angle and an interchangeable lens. The choice is therefore between appearance and width of coverage.
The position is usually to blame, not the detector. Check whether heating, air conditioning, a billowing curtain or a window in direct sunlight reaches into the field of view. If the position is in order, switch the detector to the higher immunity level.
The recommended height is 2.2 to 2.5 m above the floor. Mounting it lower or higher changes the range and the layout of the detection zones, so always verify the coverage with a walk test after mounting.
Technical specifications
- Compatible with
- F-Link 2.0.0 and higher
- Power
- from the control panel BUS 12 V (9 ... 15 V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice (maximum)
- 16 mA
- Recommended installation height
- 2.5 m above the floor
- Detection angle / detection range
- 90 °/12 m
- Dimensions
- 62 x 110 x 40 mm
- Weight
- 77 g
- Classification
- Grade 2/Environmental class II (According to EN 50131-1)
- Operational environment
- Indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational immunity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-2-2, EN 50130-4 ed. 2+A1, EN 55032, EN 50581
Warning
- Do not touch the PIR sensor inside the cover, you could damage it.
- There should be no objects that change temperature rapidly, nor any moving objects, in the detector's field of view. Do not install it opposite windows or floodlights, or in places with air flow.
- After installation, and whenever the lens or the height is changed, verify the coverage with a walk test. The actual range in the room differs from the figure in the table depending on what is in the way.
Installation example
Always connect the bus with the system power completely switched off.
Choose a position at a height of 2.2 to 2.5 m, away from windows, floodlights, heat sources and air flow.
Open the cover and take out the electronics. Do not touch the PIR sensor inside.
Punch out the holes for the screws in the rear plastic and screw it on vertically, with the cover latch facing downwards.
Put the electronics back in place.
Connect the cable to the terminals and enrol the detector according to the control unit manual.
Close the cover, secure it with the locking screw and verify its function with a walk test.
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector

JA-113M
Bus magnetic detector with recognition of external magnetic fields
Help us improve the catalog
Missing something, or found a mistake? Let us know.