JA-154E-GR
Wireless access module with display, keypad and RFID - grey
Control segments tailored to the particular premises. Traffic-light logic for quick, clear everyday control, an information display and authorisation by code or by a 125 kHz tag.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- 4 x alkaline batteries AA (LR6) 1.5 V Please note: Batteries are not included
- Power input from external supply
- 0.5 W
- Classification
- Grade II
- Dimensions
- 102 x 145 x 33 mm
Basic description
Simple, clear control of the alarm. The illuminated activation button shows the system status in green, yellow or red, and the control segments light up in colour as well. On top of that, the module gives an audible warning of the entry and exit delay and of an alarm.
- To control the system, all you need is to enter a code or present a card or tag to the reader in the module. The keypad is under a tilting cover, which can be removed for permanent access.
- Up to 20 segments in one unit, clear at first glance
- An input for a door opening detector right on the module
Why choose this product
Modular construction
The module contains 1 control segment. Further segments are sold separately and the unit can be extended to up to 20 segments including the first one.
- Up to 2 common segments per unit
Choosing the right type of keypad
A broad portfolio of keypads meets different control needs. From the main entrance through a floor or a garage to a gate or a delivery entrance.
- The main keypad of the system should always have a display for full control; choose from the JA-1x4E, JA-1x5E or JA-1x6E
- A secondary keypad on a floor or in a garage can be without a display; choose from the JA-1x3E, JA-121E or JA-123E
- For a single-purpose function such as passing through a door or opening a gate, a reader may be enough; choose from the JA-1x2E, JA-120E or JA-122E
Frequently asked questions
In the display. The JA-154E has an information LCD display, the JA-153E does not; the modular architecture, the segments and the RFID reader are the same. The JA-154E also synchronises the unit automatically after the number of segments changes, whereas with the JA-153E you have to press the Load button in F-Link.
When the installation needs more than four control elements, or when their number may change over time. The JA-154E is built up from JA-192E segments into a unit of 20 segments, whereas the JA-150E has four fixed function buttons and cannot be extended.
They are printed in F-Link on the Devices tab under Internal settings and inserted into the segment covers after installation. A colour version of the module requires JA-192E segments in a matching colour. Each segment has a legible description of what it controls, so the user does not have to remember the controls.
Technical specifications
- Power
- 4 x alkaline batteries AA (LR6) 1.5 V Please note: Batteries are not included
- Typical life time
- 1 - 2 year(s) according to the settings
- Power input from external supply
- 0.5 W
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Communication range
- 200 m (open area)
- RFID frequency
- 125 kHz
- Dimensions
- 102 x 145 x 33 mm
- Weight
- 350 g
- Classification
- Grade II
- According to
- EN 50131-1, EN 50131-3, EN 50131-5-3
- Operational environment
- EN 50131-1 II. Indoor general
- Operating temperature range
- -10 to +40 °C
- Also complies with
- ETSI EN 300 330, ETSI EN 300 220, EN 50130-4, EN 55022, EN 60950-1
- Can be operated according to
- ERC REC 70-03
Warning
The keyboard, powered by an additional source, must have batteries connected for back-up operation network outage. This keyboard works with RFID chips. If you combine it with a keyboard or reader in the installation type MiFare (NFC), equip users with dual authorization chips type XY (contain both technologies).
- Batteries are not included in the package, so add four good branded AA alkaline batteries. Switch the system to SERVICE mode before replacing the batteries, otherwise a tamper alarm will be triggered; replace the batteries within 2 weeks of the warning. The external power supply uses the PWR and GND terminals, a DE 06-12 power supply, 0.5 W input. Each further segment draws 2.5 mA, so with a full unit the total consumption has to be calculated. Do not combine the Common segment function with the Section and Common to sections function; it requires at least three segments. Without the cover latches being secured with the screws supplied, the module does not comply with EN 50131-1. The firmware update is not wireless; it requires a mini USB cable, which is not included, unlike the JA-150E keypad with its wireless update. The dimensions and weight apply to the module itself; check the length of a unit with further segments physically before choosing the place. The module belongs in an indoor environment only, −10 to +40 °C and 75 % RH non-condensing. Installation may only be carried out by a trained technician with a valid JABLOTRON certificate. The control unit must have a JA-11xR radio module within range of the access module.
Installation example
Replace the batteries and change the unit with the system switched to SERVICE mode, with the batteries removed and the external power supply disconnected.
Press the four latches on the sides one after another and release the module from the rear plastic part.
When installing another segment, first remove the end cap above the first segment.
Take the transparent covers off the segments by levering them from the side at the buttons.
Always connect the segment wire into the connector of the previous segment, coil the wires by turning the segment through 360° and fit the end cap.
Insert four 1.5 V AA (LR6) alkaline batteries.
Screw the bottom part together with the segments to the chosen place; the recommended screws are 4× Ø 3.5 × 40 mm with a countersunk head; with a larger number of segments, fix the segments to the wall as well.
Click the module into the unit.
Make sure that a JA-11xR radio module is installed in the system and within range of the module.
In F-Link, on the Devices tab, select the position, switch on enrolment mode with the Enrol option and press the illuminated activation button; alternatively, enrol it by entering the serial number or with the bar code.
Insert the labels into the segment covers and close the covers; printing the labels is part of F-Link.
To comply with EN 50131-1, secure the cover latches with the screws supplied.
Accessories
Related products

JA-155E
Wireless four-segment keypad with display and RFID reader

JA-156E
Wireless touchscreen keypad with reader RFID

JA-152E
Wireless access module with RFID

JA-153E
Wireless access module with RFID and keypad

JA-154E
Wireless access module with display, keypad and RFID

JA-151E
Wireless Chip Reader for Section Control

JA-153E-AN
Wireless access module with RFID and keypad - anthracite

JA-153E-GR
Wireless access module with RFID and keypad - grey

JA-154E-AN
Wireless access module with display, keypad and RFID - anthracite

JA-156E-AN
Wireless touchscreen keypad with reader RFID - Anthracite

JA-156E-GR
Wireless touchscreen keypad with reader RFID - grey

JA-155E-AN
Wireless four-segment keypad with display and RFID reader - anthracite
Help us improve the catalog
Missing something, or found a mistake? Let us know.