JA-154P
Wireless PIR motion detector
A version with two-way communication for standard interiors. Coverage angle 110°, range 12 m. Adjustable immunity to false alarms, and it can be installed later on without any cabling.
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- 2x alkaline batteries, type LR6 (AA) 1.5 V Note: Batteries are not included.
- Typical battery life
- approximately 4 years
- Low battery voltage
- <2.4 V
- Nominal current consumption
- 36 μA
- Maximum current consumption
- 50 mA
- Communication frequency
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- <25 mW
Basic description
The passive infrared detector not only detects an intruder, it also serves for lighting automation and other scenarios. The settings can be changed remotely, with no trip to the detector.
- Adjustable sensitivity
- Fan-shaped characteristic, optional JS-7904 corridor lens or JS-7902 vertical lens
Why choose this product
How the detector works
It responds to changes in the thermal image within its field of view. It is triggered when it sees the movement of a larger body at a temperature close to that of a human. It is suitable for ordinary interiors where no sharp temperature fluctuations occur. Correct positioning is essential. If disturbing stimuli do appear in the area, the immunity can be increased remotely.
- Covers a room of ordinary size
- Typically mounted in a corner, but also on a flat wall at a height of 2.2 to 2.5 m
One detector, plenty of functions
Besides picking up an uninvited guest, the detector can also be used for comfort functions. No additional sensors are needed. The alarm detector is therefore suitable for automating lighting or other appliances as well.
- Lights switched on automatically on movement after dark, and switched off automatically in a room where nobody has moved for a longer time
- Convenient switching of the air conditioning based on movement when entering the room
- Movement information passed on to the smart home
Positioning rules
A few basic rules have to be kept in mind for PIR detectors to work correctly. Given the detector's operating principle, unsuitable positioning may cause false alarms or insufficient coverage of the room.
- Keep to the recommended installation height and, after replacing the lens, verify that the detector covers the area correctly
- Avoid positioning it opposite windows and close to heating or air handling, where sharp temperature fluctuations are a risk
Frequently asked questions
It saves trips to the detector. Enrolment is done from F-Link, so you do not have to insert the batteries right at the detector, and you can fine-tune the sensitivity and other settings remotely even after the premises have been handed over. With a detector under the ceiling that means several trips up the stepladder fewer.
The position is usually to blame, not the detector. Check whether heating, air conditioning, a billowing curtain or a window in direct sunlight reaches into the field of view. If the position is in order, switch the detector to the higher immunity level.
The recommended height is 2.2 to 2.5 m above the floor. Mounting it lower or higher changes the range and the layout of the detection zones, so always verify the coverage with a walk test after mounting.
Technical specifications
- Power
- 2x alkaline batteries, type LR6 (AA) 1.5 V Note: Batteries are not included.
- Typical battery life
- approximately 4 years
- Low battery voltage
- <2.4 V
- Nominal current consumption
- 36 μA
- Maximum current consumption
- 50 mA
- Communication frequency
- 868.1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- <25 mW
- Communication range
- approx. 500 m (open terrain)
- Recommended installation height
- 2.2 to 2.5 m above floor level
- Detection angle / detection coverage
- 110 ° / 12 m (with basic lens)
- Dimensions
- 60.8 x 97.5 x 51.8 mm
- Weight (without batteries)
- 82 g
- Classification
- security grade 2 / environment class II (according to EN 50131-1)
- Environment
- Indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operating humidity
- 75 % RH, non-condensation
- Certification body
- Trezor Test s.r.o. (No. 3025), Kiwa Nederland b. v.
- Complies with
- EN 50131-2-2, EN 50131-5-3, EN 50131-6, EN 50130-4, ETSI EN 300 220-2, EN 55032, EN IEC 62368-1, EN IEC 63000, T 031
- Operating conditions according to general authorisation
- ERC REC 70-03
- Recommended screw
- 2x ø 3.5 x 40 mm (countersunk head)
Warning
- Do not touch the PIR sensor inside the cover, you could damage it.
- There should be no objects that change temperature rapidly, nor any moving objects, in the detector's field of view. Do not install it opposite windows or floodlights, or in places with air flow.
- The increased immunity level cannot be used with the JS-7904 corridor lens. With that lens, or with the JS-7902 vertical lens, the detector does not comply with EN 50131-2-2:2021.
- Do not credit this model with pet immunity; that is provided by the separate JA-154P PET.
- Always replace all the batteries together. Before enrolling it again with the batteries inserted, take them out first and press the tamper contact so that the residual current is discharged.
- To comply with EN 50131 and INCERT (T 031), leave the immunity level at Standard.
- The control unit must have a JA-11xR radio module.
- When switching a light via a PG output, set the PG time longer than the reporting interval of the selected operating mode, otherwise the light will go out during continuous movement.
- The JA-121T module is needed to pass information on to the smart home.
Installation example
Choose a place at a height of 2.2 to 2.5 m, away from windows, shiny surfaces, heat sources, air flow and moving objects.
Open the cover and take out the electronics. Do not touch the PIR sensor inside.
Punch out the holes for the screws in the rear plastic and screw it on vertically, with the cover latch facing downwards.
Put the electronics back in and insert both batteries, minding the polarity.
Enrol the detector according to the control unit manual.
Close the cover, secure it with the locking screw and verify its function with a walk test.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer
Help us improve the catalog
Missing something, or found a mistake? Let us know.