JA-180W
Wireless PIR and MW combined detector
DiscontinuedA wireless detector, part of the JABLOTRON 100+ system, that combines a PIR part and a microwave part and only sends an alarm after confirmation by both. The PIR coverage angle is 110° and the range 12 m. It communicates by radio and is battery-powered.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power supply
- Lithium battery type CR14500 (AA) 3.6 V/2.45 Ah Please note: Battery is not included
- Nominal current
- 21 µA
- Maximal current
- 38 µA
- Battery low voltage
- ≤ 2.6 V
- Typical battery lifetime
- approx. 2 years (DIP no. 3 to NORM)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx. 300 m (open area)
Basic description
The JA-120PW and JA-180W are older designs of the dual PIR and microwave detector, set with switches and a trimmer potentiometer instead of F-Link. The newer generation with the same principle, but with settings in F-Link and in more compact and design versions, is represented by the JA-121PW, JA-161PW, JA-122PW and JA-162PW.
- Confirmed PIR and microwave detection, part of the JABLOTRON 100+ system. An alarm is only triggered after confirmation by both principles; a thermal event on its own does not cause an alarm.
- Installation without cables. Battery-powered; installation requires no cabling and no chasing into walls.
- PIR coverage angle 110° and range 12 m. The microwaves confirm within 24° in open space and approximately 90° in a furnished room, with a range of 15 m.
- Dual evaluation in one module. Occupies one system position.
Why choose this product
Confirmed dual detection
The PIR part registers movement and activates the microwave part, and the alarm is only sent after confirmation by both. In this way, the detector limits false alarms caused by a change in temperature alone.
- Wireless transmission at 868.1 MHz, range approximately 300 m
- PIR coverage angle 110° / 12 m, microwaves up to 90° in a furnished room / 15 m
- Occupies one system position
Settings and immunity
You set the immunity of both the PIR and the microwave part to false alarms in F-Link, and the microwave range with a trimmer potentiometer directly on the detector. The tamper contact reports both opening of the cover and removal.
- PIR and microwave immunity Standard / Enhanced, set in F-Link
- Microwave range set with a trimmer potentiometer, approximately 1 to 15 m
- Set the microwave range so that it does not exceed the PIR field of view
Microwave specifics
Microwaves can pick up movement even behind a non-metallic obstacle, such as a thin wall, a door or glass, so limit the range with the trimmer potentiometer so that it does not extend into neighbouring rooms or the corridor.
- Microwaves pass through non-metallic obstacles (wall, door, glass)
- Only one microwave detector per room
- After setting, return the test switch to NORM mode
Frequently asked questions
A PIR on its own can react to heat or a draught. The microwave part confirms its activation, and the alarm is only sent after both, so there are fewer false alarms.
Microwaves pass through non-metallic obstacles, such as a thin wall, a door or glass. Therefore limit the range with the trimmer potentiometer to the PIR field of view and check it with a test after installation.
The JA-161PW has the same confirmation principle, but with settings in F-Link instead of DIP switches. The JA-180W remains in the range for existing wireless installations.
Technical specifications
- Power supply
- Lithium battery type CR14500 (AA) 3.6 V/2.45 Ah Please note: Battery is not included
- Nominal current
- 21 µA
- Maximal current
- 38 µA
- Battery low voltage
- ≤ 2.6 V
- Typical battery lifetime
- approx. 2 years (DIP no. 3 to NORM)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx. 300 m (open area)
- Recommended installation height
- 2.0 to 2.5 m above floor level
- PIR detection angle/detection range
- 110°/12 m (with basic lens)
- MW detection angle/detection range
- 24°/15 m (open area)
- MW detection angle/detection range
- 90°/15 m (sample room)
- MW detection range/frequency
- 9.35 GHz
- Dimensions
- 110 x 60 x 51 mm
- Weight
- 114 g
- Classification
- Security grade 2/Environmental class II
- - according to
- EN 50131-1, EN 50131-2-4, EN 50131-5-3
- - operational environment
- Iindoor general
- - operational temperature range
- -10 °C to +40 °C
- - average humidity
- 75 % RH non condensing
- - certification body
- Trezor Test s,r.o. (no. 3025)
- Complies with
- ETSI EN 300 220, ETSI EN 300 440, EN 50130-4, EN 55022, EN 60950-1
- Can be operated according to
- ERC REC 70-03
Warning
- The microwave range must not exceed the PIR field of view, otherwise the detector reports movement outside the protected area. Do not install two microwave detectors in one room; their transmitters would interfere with each other. Microwaves pass through non-metallic obstacles; take this into account with thin walls, doors or glass. Do not touch the PIR sensor inside the cover.
Installation example
Place the detector on a wall or in a corner approximately 2.5 m above the floor, away from metal objects that shield the radio and the microwave field.
Insert the battery and wait up to three minutes for stabilisation. Enrol the detector according to the control unit manual; the control unit must have a JA-11xR radio module.
Use the switches and the trimmer potentiometer to set the sensitivity of both the PIR and the microwaves, and the confirmation time if required, and limit the microwave range to the PIR area.
Return the test switch to NORM mode and check the actual coverage of the room.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer
Help us improve the catalog
Missing something, or found a mistake? Let us know.