JA-186P
Wireless dual PIR indoor detector
DiscontinuedWireless dual-zone PIR detector for the movement of persons indoors. Two separate detection zones limit the reaction to the movement of pets. It belongs to the previous JA-18x platform.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K
Check compatibilityKey specifications
- Voltage
- LS(T)14500 (3.6V AA/2 Ah) type lithium battery Please note: Battery is not included
- Typical battery lifetime
- approx. 3 years (5 min. sleep mode)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx 300 m (open area)
- Recommended installation height
- 1.2 m above the floor
- Detection angle/detection range
- 120°/12 m (with basic lens)
- Operational environment according to EN 50131-1
- II. indoor general
Basic description
The JA-18x series is an older wireless platform. The detectors are set using switches on the board, not with the F-Link software, and are enrolled by inserting the battery. Do not transfer them to JABLOTRON 100+ systems; the JA-11x and JA-15x series are intended for new installations.
- Two zones limit the reaction to an animal. An alarm is triggered only when movement affects both zones, which a small animal does not usually do.
- Installation without a cable. It is powered by a single lithium battery; mounting requires no cabling.
- Two zones, each with a coverage angle of 120° and a range of 12 m.
- You set it using switches directly on the detector. You choose the reaction, immunity and sleep time without software and without a computer.
Why choose this product
How dual-zone evaluation works
An alarm is triggered only when movement shows up in two separate parts of the field of view. The stricter mode is even more demanding in this respect. Immunity to animals thus results from the principle, not from a declared weight limit.
- Two zones, each 120° and 12 m
- NORM mode: movement in both zones within 3 s
- HIGH mode: two NORM activations within 10 s
Settings using switches
Two switches on the board determine how the detector behaves: the alarm reaction mode and the signal evaluation level. Settings are made manually on the detector; no software is used for this.
- Switch 1: delayed or instant reaction
- Switch 2: NORM or HIGH evaluation strictness
- For a standard-compliant installation, secure the cover latch with a screw
How the detector is connected
The detector communicates by radio and is powered by a single lithium battery, so mounting requires no cabling. It is enrolled by inserting the battery, after which it stabilises for approximately one minute. Metal objects in the vicinity can attenuate radio communication.
- Radio at 868.1 MHz, range approximately 300 m
- LS(T)14500 AA battery, service life approximately 3 years
- Recommended mounting height 1.2 m
Frequently asked questions
An alarm is triggered only when both zones are affected. In NORM mode, movement must occur in both within three seconds; in HIGH mode, two such activations within ten seconds are needed. A small animal does not usually affect both zones, but this is a principle, not a declared weight limit.
The most common cause is unsuitable placement. Check whether a heat source, air flow, a moving object or a pet extends into the field of view. Only then change the immunity setting using the switch.
The recommended height is approximately 1.2 m above the floor, which is considerably lower than for a typical wall-mounted PIR. At a different height, the layout of both zones changes, so check the coverage with a walk test after mounting.
Technical specifications
- Voltage
- LS(T)14500 (3.6V AA/2 Ah) type lithium battery Please note: Battery is not included
- Typical battery lifetime
- approx. 3 years (5 min. sleep mode)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx 300 m (open area)
- Recommended installation height
- 1.2 m above the floor
- Detection angle/detection range
- 120°/12 m (with basic lens)
- Operational environment according to EN 50131-1
- II. indoor general
- Operational temperature range
- -10 °C to +40 °C
- Dimensions, weight
- 180 x 60 x 55 mm, 200 g
- EN 50131-1, EN 50131-2-2, EN 50131-5-3 classification
- grade 2
- Complies with
- ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
- Can be operated according to
- ERC REC 70-03
Warning
- Do not point the field of view at sources of rapid temperature changes, windows, spotlights or air flow.
- Immunity to animals is given by the dual-zone principle, not by a declared weight limit. If you need a limit, choose the PET model.
- Metal objects in the vicinity can attenuate radio communication.
- After dismounting, delete the detector from the control unit or use bypass.
Installation example
Choose a location approximately 1.2 m above the floor, away from windows, spotlights, sources of rapid temperature changes and air flow.
Insert the battery according to the procedure for the control unit or receiver and wait approximately one minute for stabilisation.
Set the reaction and evaluation strictness using the switches.
For a standard-compliant installation, secure the cover latch with the supplied screw and check the function with a walk test.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer
Help us improve the catalog
Missing something, or found a mistake? Let us know.