JA-110F
Bus flood detector
Catching the risk of a water escape in technical or hard-to-reach spaces. Maintenance-free operation thanks to power from the bus.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- from control panel digital bus 12 V (9 … 15 V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable selection
- 5 mA
- Detector
- reacts to flooding by water
- Dimensions
- 53 x 20 x 10 mm
- Operational environment according to
- EN 50131-1 II Indoor general
- Operating temperature range
- -10 °C to +40 °C
Basic description
Statistically, flooding is the most frequent cause of an insurance claim in households. When a hose bursts or a seal fails, the detector responds at the very first drops. It makes it possible to act immediately and prevent greater damage.
- Can be linked to a smart valve for an automatic response
- Resistance to splashing water (the detector is not intended for permanent immersion)
- Alarm and notification whether the alarm system is unset or set
Why choose this product
A solution for demanding spaces
The detector is simply glued or screwed on so that the pair of contacts sits where the water will run during an escape. Its miniature dimensions mean it fits almost anywhere. Power from the bus and a non-dismountable body ensure completely maintenance-free operation. The detector is therefore suitable even for places that are hard to reach.
- Shafts and recesses
- Spaces behind tanks and pipework
- Enclosures for a wall-hung toilet and similar
Linking to a smart valve
For genuine protection against flooding even at a moment when nobody is on the premises, add a smart valve to the main water stopcock.
- Automatic shut-off immediately on detection of an escape
- Preventive shut-off after leaving protects the whole building regardless of detector coverage
Frequently asked questions
The water interconnects its detection electrodes. The detector then reports an activation and, once the water level drops, also a return to normal, so the system shows when the flooding started and when it ended. That says nothing about whether the escape has been repaired.
No, the detection electrodes are part of the module itself. Therefore position the whole module where the water will run, and leave the electrodes lying on the floor.
Yes, in F-Link in the range 0.5 to 300 s. You can also set an inverse reaction of the input and the LED alarm memory, which stays on until it is cancelled by the control unit.
Technical specifications
- Power
- from control panel digital bus 12 V (9 … 15 V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable selection
- 5 mA
- Detector
- reacts to flooding by water
- Dimensions
- 53 x 20 x 10 mm
- Operational environment according to
- EN 50131-1 II Indoor general
- Operating temperature range
- -10 °C to +40 °C
- Also complies with
- EN 50130-4, EN 55022
Warning
- The detection electrodes must be at the lowest point where the water will flow. The detector is not designed for permanent immersion below the surface and is not suitable for aggressive liquids, for example for the sump of a wastewater treatment plant. Connect the bus only with the power supply completely switched off. If the module is outside the protected space, its feed must be separated with a JA-110T bus isolator. The reaction delay can be set in the range 0.5 to 300 s; a longer delay limits spurious activation but extends the time to the alarm. The specified environment is II, indoor – general.
Installation example
Always connect the bus with the system power completely switched off.
Position the module so that its detection electrodes lie in the place being monitored.
Connect the bus cable to the module terminals; the JA-190PL installation box can be used for the terminal block.
If the module is outside the protected space, separate its feed with a JA-110T bus isolator.
Enrol the detector by interconnecting its own electrodes briefly.
In F-Link, set the reaction delay, and the inverse reaction and LED alarm memory if required.
Test the function by interconnecting the detection electrodes.
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.