JA-111H-AD TRB
Bus module for system control
BUS module for connecting an external control device to the JABLOTRON 100+ system. It allows the system to be set and unset with that device and powers the device from the bus. Occupies one system position.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption - Nominal consumption - to calculate backup
- 8 mA all inputs connected to GND (+ consumption of connected devices)
- Current consumption - Maximal consumption - for cable selection
- 12 mA (+ consumption of connected devices)
- Maximum allowed current of the connected detector
- 50 mA
- Dimensions
- 16 x 30 x 12 mm
- Weight
- 8 g
- Classification
- Security grade 2 / environmental class II
Basic description
The JA-111H-AD TRB connects an external control device, i.e. a device that controls the system by setting and unsetting it, to the JABLOTRON 100+ system. The AD suffix indicates precisely this use for system control, not for connecting a detector. A wired detector that reports its status is connected by the JA-111H TRB module; where several wired inputs are to be added at once, the JA-114HN or JA-116H is the right choice.
- Connects an external control device. Use it to set and unset the system.
- Control and power over one bus. The module also powers the connected control device.
- Dimensions 16 × 30 × 12 mm, weight 8 g.
- Fits into the system like any other peripheral. It occupies one position and reports to the control unit under its own address.
Why choose this product
System control by a third-party device
The module gives the system an interface through which even a device from another manufacturer can set and unset it. In the default setting, a single wire is enough and the system monitors its status; the second option works with two wires, one for setting and the other for unsetting. Polarity, reaction and delay are set in the configuration software, so the module adapts even to a device that was not originally designed for the system.
- Single-wire status and pulse control
- The INP input sets, the TRB input unsets
- Controls programmable outputs, activation time 0.1 to 300 s
Power supply and connecting wires
The module is powered from the control unit bus and supplies current to the connected control device in the same way. This power output is not protected against overload, so the consumption of the control device must be known in advance. The supply wires may be extended, so the control device does not have to sit right next to the module.
- Rated consumption 8 mA, maximum 12 mA
- Output load 50 mA maximum
- Wires 30 cm, can be extended to a maximum of 3 m
Purpose and limitations
The module does not choose who gives it a command. All that matters is what the control device offers at the terminals: a contact or pulse, and a consumption the power output can handle. How much current the device draws is therefore the first thing you find out about it.
- Installation may only be carried out by a trained technician holding a valid manufacturer's certificate
- The module is classified in Security Grade 2, but in a system configured for this grade the control functions are not supported
- Mounted inside the control device or in a protected installation box
Frequently asked questions
For connecting an external control device used to set and unset the system. The module also powers the device from the bus.
No. The control functions are not supported in a system configured to meet Security Grade 2. The module itself is classified in Security Grade 2; that does not change.
The JA-111H-AD TRB is for a control device; the AD suffix indicates use for system control. The JA-111H TRB is for a wired detector that reports its status.
Technical specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption - Nominal consumption - to calculate backup
- 8 mA all inputs connected to GND (+ consumption of connected devices)
- Current consumption - Maximal consumption - for cable selection
- 12 mA (+ consumption of connected devices)
- Maximum allowed current of the connected detector
- 50 mA
- Dimensions
- 16 x 30 x 12 mm
- Weight
- 8 g
- Classification
- Security grade 2 / environmental class II
- - according to
- EN 50131-1, EN 50131-3 (ACE type B)
- - environmental
- Indoor general
- - operating temperature range
- -10 °C to +40 °C
- - average humidity
- 75 % RH non condensing
- Also complies with
- EN 50130-4, EN 55022
Warning
- Always connect the bus with the system power completely switched off. The power output of the module is not protected against overload; the consumption of the connected control device must remain below the limit stated for the power supply. The manufacturer guarantees the function of the module, not the behaviour of the control device you connect to it, and recommends JABLOTRON system control devices and access modules as the first choice.
Installation example
Always connect the bus with the system power completely switched off.
Place the module inside the control device or in a protected installation box.
Connect the bus and a control device whose consumption the power output can handle.
Enrol the module in the configuration software in service mode, using the tamper contact or the serial number.
Select single-wire or two-wire control, NC/NO polarity and the input delays.
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.