JA-112J

Bus emergency/control wall-mounted button

A wall button for the JABLOTRON system, connected via the bus. Under its movable cover it has two buttons, A and B, and it is primarily used to control appliances via PG outputs. It is installed by a trained technician with a valid JABLOTRON certificate.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K

Check compatibility

Key specifications

Power
from the control panel digital BUS 12 V (9 - 15V)
Current consumption in standby mode
5 mA
Current consumption for cable choice
5 mA
Dimensions, weight
80 x 80 x 29 mm, 60g
Operational environment according to EN 50131-1
II. Indoor general
Operation temperature range
-10 °C to + 40 °C
Complies with
EN 50130-4, EN 55022, EN 50581

Basic description

With the four wall buttons, a single question decides: is there a bus at the location or not? Where there is, the JA-112J belongs. Where there is no cable, you choose between the wireless ones: the JA-158J confirms back that the system has actually carried out the command, the JA-188J is configured with switches directly in its box, and the JA-159J is a doorbell button for an outdoor entrance. What a press should do does not divide the family: hold-up alarm, doorbell and control of appliances are a matter of settings for all of them.

  • What the button does is decided by its settings, not by the product type. The very same button can therefore control appliances in one place and trigger an alarm in another.
  • Both power and commands are carried by the control unit bus. The button has no battery that would need to be monitored and replaced.
  • You select the function in F-Link at the position to which the button is enrolled. Changing the reaction is therefore a matter of settings, not of replacing the product.
  • It is not certified as a hold-up device for security grade 2. Where a project requires certified hold-up signalling, do not count on it.

Why choose this product

What happens after a press

A press has a single task: to send the system a command. What happens next is determined by the reaction assigned to the position to which the button is enrolled in the system, from switching a PG output to triggering an alarm. If the product has two buttons, A and B, each can carry a different reaction; they can also carry the same one, in which case it does not matter which is pressed. A single button always carries only one reaction.

  • Main purpose: control of appliances via PG outputs
  • Activation delay of 0–99 s for hold-up or fire reactions; pressing again during the delay cancels the action

What the system needs for it

The button is a peripheral like any other. In the F-Link program, the position to which the button is enrolled is selected on the Devices tab, and a reaction is assigned to the same position. It can also be enrolled by entering the product's serial number.

  • The control unit communicates with it via the bus
  • LED indication can be enabled; when signalling the PG output state, it then lights red with the output on and green with the output off

Where it is installed

The bottom part is fixed in the chosen place, the part with the electronics clicks into it and the bus cable is led into the terminal block. When the bottom part is used, the magnet of the tamper sensor is moved from the part holding the electronics to the bottom part. If the button is to be used for hold-up alarms, it must always be installed with the bottom part and with the bottom tamper contact enabled.

  • Powered from the control panel bus, 12 V (9–15 V)
  • Indoor – general environment, −10 °C to +40 °C

Frequently asked questions