JA-112J
Bus emergency/control wall-mounted button
A wall button for the JABLOTRON system, connected via the bus. Under its movable cover it has two buttons, A and B, and it is primarily used to control appliances via PG outputs. It is installed by a trained technician with a valid JABLOTRON certificate.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- from the control panel digital BUS 12 V (9 - 15V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice
- 5 mA
- Dimensions, weight
- 80 x 80 x 29 mm, 60g
- Operational environment according to EN 50131-1
- II. Indoor general
- Operation temperature range
- -10 °C to + 40 °C
- Complies with
- EN 50130-4, EN 55022, EN 50581
Basic description
With the four wall buttons, a single question decides: is there a bus at the location or not? Where there is, the JA-112J belongs. Where there is no cable, you choose between the wireless ones: the JA-158J confirms back that the system has actually carried out the command, the JA-188J is configured with switches directly in its box, and the JA-159J is a doorbell button for an outdoor entrance. What a press should do does not divide the family: hold-up alarm, doorbell and control of appliances are a matter of settings for all of them.
- What the button does is decided by its settings, not by the product type. The very same button can therefore control appliances in one place and trigger an alarm in another.
- Both power and commands are carried by the control unit bus. The button has no battery that would need to be monitored and replaced.
- You select the function in F-Link at the position to which the button is enrolled. Changing the reaction is therefore a matter of settings, not of replacing the product.
- It is not certified as a hold-up device for security grade 2. Where a project requires certified hold-up signalling, do not count on it.
Why choose this product
What happens after a press
A press has a single task: to send the system a command. What happens next is determined by the reaction assigned to the position to which the button is enrolled in the system, from switching a PG output to triggering an alarm. If the product has two buttons, A and B, each can carry a different reaction; they can also carry the same one, in which case it does not matter which is pressed. A single button always carries only one reaction.
- Main purpose: control of appliances via PG outputs
- Activation delay of 0–99 s for hold-up or fire reactions; pressing again during the delay cancels the action
What the system needs for it
The button is a peripheral like any other. In the F-Link program, the position to which the button is enrolled is selected on the Devices tab, and a reaction is assigned to the same position. It can also be enrolled by entering the product's serial number.
- The control unit communicates with it via the bus
- LED indication can be enabled; when signalling the PG output state, it then lights red with the output on and green with the output off
Where it is installed
The bottom part is fixed in the chosen place, the part with the electronics clicks into it and the bus cable is led into the terminal block. When the bottom part is used, the magnet of the tamper sensor is moved from the part holding the electronics to the bottom part. If the button is to be used for hold-up alarms, it must always be installed with the bottom part and with the bottom tamper contact enabled.
- Powered from the control panel bus, 12 V (9–15 V)
- Indoor – general environment, −10 °C to +40 °C
Frequently asked questions
Whatever the engineer has set for it in F-Link. Most often it switches a PG output on or off, for example a light or a gate. If a hold-up or fire type of reaction is set for the position, it sends it to the system, which handles it according to the settings of the whole installation.
Technical specifications
- Power
- from the control panel digital BUS 12 V (9 - 15V)
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice
- 5 mA
- Dimensions, weight
- 80 x 80 x 29 mm, 60g
- Operational environment according to EN 50131-1
- II. Indoor general
- Operation temperature range
- -10 °C to + 40 °C
- Complies with
- EN 50130-4, EN 55022, EN 50581
Warning
- Always connect the bus with the system power completely switched off. If the button is installed outside the protected building, use a bus isolator for that part of the bus. This is not a recommendation but a requirement, and it concerns the security of the whole system.
Installation example
Open the movable cover from the side with a screwdriver.
Release the bottom part by pressing the four latches in the corners.
Pull the bus cable through the bottom part and fix the part in the chosen place with two Ø 3.5 × 40 mm screws with a countersunk head.
Click the part with the electronics into it. When using the bottom part, move the magnet of the tamper sensor from the part holding the electronics to the bottom part.
With the system power completely switched off, connect the bus cable to the terminal block.
Close the top movable cover of the button.
Switch on the system power. A flashing yellow LED means that the button has not yet been enrolled. In F-Link, select the required position on the Devices tab, switch on enrolment mode with the Enrol button and press button A or B; the yellow LED goes off. It can also be enrolled by entering the serial number from the board below the bar code, or with the Scan/add new BUS devices option.
Set the function of the button in F-Link with the Internal settings option on the Devices tab.
Help us improve the catalog