JA-158J
Wireless wall button
A wall button for the JABLOTRON system, wireless and two-way. Under its top cap it has a cradle with two buttons, A and B, and it reports back that a command has been carried out. It is installed by a trained technician with a valid JABLOTRON certificate.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- 2x Lithium Battery type CR 2032 (3.0 V/0.2 Ah) (Type C power supply in accordance with EN 50131-6) Important: Batteries are not included in the packaging
- Communication range
- approx. 300 m (line-of-sight)
- Dimensions
- 80 x 80 x 20 mm
Basic description
With the four wall buttons, a single question decides: is there a bus at the location or not? Where there is, the JA-112J belongs. Where there is no cable, you choose between the wireless ones: the JA-158J confirms back that the system has actually carried out the command, the JA-188J is configured with switches directly in its box, and the JA-159J is a doorbell button for an outdoor entrance. What a press should do does not divide the family: hold-up alarm, doorbell and control of appliances are a matter of settings for all of them.
- What the button does is decided by its settings, not by the product type. The very same button can therefore control appliances in one place and trigger an alarm in another.
- It communicates using the JABLOTRON wireless protocol and carries its own power supply. You therefore do not run any cable to the button.
- No function is set at the factory. You determine the reaction of each of the two buttons in F-Link.
- Complies with security grade 2 and environmental class II according to EN 50131-1. However, when the Unset function is used, it does not meet the requirements of this standard, because unsetting does not require confirmation by authorisation.
Why choose this product
What happens after a press
A press has a single task: to send the system a command. What happens next is determined by the reaction assigned to the position to which the button is enrolled in the system, from switching a PG output to triggering an alarm. If the product has two buttons, A and B, each can carry a different reaction; they can also carry the same one, in which case it does not matter which is pressed. A single button always carries only one reaction.
- Panic button, wireless doorbell, system control or control of appliances
- For control of appliances, a PG output and one of the modes is assigned to the activation: on, copy or change of state
- For the Panic and Audible panic reactions, a delay of 5–240 s can be set, which a further press cancels; the button can also take over the access privileges or the identity of a selected user in the event log
What the system needs for it
The button is a peripheral like any other. In the F-Link program, the position to which the button is enrolled is selected on the Devices tab, and a reaction is assigned to the same position. It can also be enrolled by entering the product's serial number.
- The control unit must be fitted with a JA-11xR radio module
- It can be enrolled to one control unit only
- It communicates with the radio module two-way and asynchronously: it confirms execution of a command visually and, if set, also acoustically. In normal operation, it receives from the control unit at most once every 20 minutes, so a change of settings may only take effect after this delay
Where it is installed
It is always installed on a flat surface: the bottom part on the wall, the middle part with the electronics on it, and the top cap on top. The arrow marked TOP on the bottom part must point upwards. If the button is only to control an appliance, for example a light or a fan, just the middle part with the cap can be fixed to a wiring box, and the rear tamper switch is then disabled.
- Power is supplied by two CR 2032 lithium batteries; typical life is approximately 3 years at 1 activation a day
- Indoor – general environment, −10 °C to +40 °C
- Range approximately 300 m in direct line of sight
Frequently asked questions
It sends the system a command according to the reaction assigned to its position: it sets or unsets a section, triggers an audible or silent hold-up alarm, a fire alarm or a medical emergency, switches a PG output, or sends a preset report. At the same time, it shows that the command has gone through: it confirms it visually and, if the engineer sets it up that way, acoustically as well.
Technical specifications
- Power
- 2x Lithium Battery type CR 2032 (3.0 V/0.2 Ah) (Type C power supply in accordance with EN 50131-6) Important: Batteries are not included in the packaging
- Typical battery lifetime
- approx. 2 years (if activated 3x per day)
- Quiescent power consumption
- 5 µA
- Maximum power consumption
- 40 mA
- Low battery threshold
- < 2,4 V
- Communication frequency
- 868.1 MHz, Jablotron protocol
- Maximum radio-frequency output (ERP)
- 8 mW
- Communication range
- approx. 300 m (line-of-sight)
- Classification
- Security grade 2/environmental class II (EN 50131-1)
- Environment
- Indoor general
- Ingress Protection Code
- IP 22
- Operational temperature range
- -10 °C to +40 °C
- Average operating humidity
- 75 % RH, w/o condensation
- Dimensions
- 80 x 80 x 20 mm
- Weight (w/o batteries)
- 58 g
- Operating conditions according to
- ERC/REC 70-03
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Additionally in compliance with
- ETSI EN 300 220-1,-2, EN 55032, EN 50130 4, EN 62368-1, EN 62311, EN 50581, EN 50131-1, EN 50131-3, EN 50131-5-3, EN 50131-6, CLC/TS 50131-11, EN 50134-2
- Recommended screw
- 2 x o3,5 x 40 mm (countersunk head)
Warning
- Where the installation relies on the standard, do not assign the Unset function to the button.
Installation example
Remove the top cap by levering it out with a flat-blade screwdriver.
Separate the middle part from the bottom part: with a flat-blade screwdriver held at an angle of approximately 45°, release all four latches one after another.
Fix the bottom part in the required place with two Ø 3.5 × 40 mm screws with a round or cheese head. Make sure the arrow marked TOP points upwards.
Fit the middle part onto the bottom part so that all four latches snap back into place.
In F-Link, select the required position on the Devices tab and switch on enrolment mode with the Enrol option.
Insert both batteries. This makes the button send the enrolment signal and enrol to the selected position. It can also be enrolled by entering the serial number from the sticker on the back, or by pressing both buttons A and B at the same time for longer than 6 seconds with the top cover removed.
Set the properties of the button in F-Link with the Internal settings option on the Devices tab.
For fixing to a KU68 wiring box, fix only the middle part of the product with the cap, and disable the rear tamper switch in the internal settings.
Related products

JA-185J
Remote control for car

JA-156J
Wireless multifunctional panic button

JA-157J
Wireless wrist and necklace panic button

JA-159J
Wireless doorbell button

JA-152J MS II
Bi-directional two-button keyfob

JA-154J MS II
Bi-directional four-button keyfob

JA-112J
Bus emergency/control wall-mounted button

JA-188JDiscontinued
Wireless panic button

JA-187JDiscontinued
Wireless wrist button
Help us improve the catalog
Missing something, or found a mistake? Let us know.