JA-157J
Wireless wrist and necklace panic button
A wireless panic button for summoning help, which the user always carries with them. A single press triggers a hold-up alarm in the JABLOTRON security system. It can be worn on the wrist like a watch or around the neck on a lanyard, or fixed to a surface with a holder.
Product line
- JABLOTRON 100+
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- lithium battery, type CR 2032 (3.0 V/0.2 Ah)
- Typical battery lifetime
- approx. 3 years (if activated once per day)
- Quiescent current consumption
- 6 µA
- Maximum current consumption
- 40 mA
- Communication band
- 868.1 MHz, Jablotron protocol
- Maximum radio-frequency output (ERP)
- 5 mW
- Communication range
- approx. 300 m (unrestricted area)
Basic description
Panic buttons are divided according to where help needs to be summoned from. The JA-157J and JA-187J are worn on the body, so they go with the user throughout the building, whereas where help is summoned from one fixed place, the button belongs on the wall or at the workstation. Among the wearable ones, the deciding factors are the range and the environment in which the user is to wear the button.
- The button is intended for summoning help personally: the user always has it with them and can therefore trigger a hold-up alarm from wherever they happen to be.
- It communicates using the JABLOTRON wireless protocol and is powered by a single lithium battery, so it needs no cabling.
- Range approximately 300 m in direct line of sight, so the button works even at the other end of the house or in the garden.
- Complies with security grade 2 and environmental class II according to EN 50131-1.
Why choose this product
What pressing the button does
The user triggers a hold-up alarm by pressing the single button they carry with them. The button sends the information by radio to the control unit, which starts the reaction set for its position. What the user sees or hears at that moment depends on the version of the button and its settings.
- A press sends the hold-up information straight away; for the Silent panic and Audible panic reactions, a delay can be set during which the user can cancel the alarm with another press.
- In addition to a hold-up alarm, the button can also be used to control appliances.
- If visual signalling is enabled, a long flash of the red LED confirms correct communication, and a yellow flash means that the control unit did not receive the hold-up signal.
What the system must be able to do
The button is a peripheral of a JABLOTRON control unit: it is enrolled to the system, and the reaction a press should trigger is set for it in the F-Link program. The engineer can check the quality of its signal at any time on the Diagnostics tab.
- The control unit must have a JA-11xR radio module.
- The button occupies one position in the system.
- Two-way asynchronous communication with the radio module allows the internal settings to be changed remotely; in normal operation, the button receives at most once every 20 minutes, so a change may only take effect after this delay.
Wearing and environment
The button is worn on the wrist like a watch or around the neck on a lanyard, or it is fixed to a mounting surface with a simple holder. Even when screwed to the holder, it remains a portable device, so the user can take it with them at any time. It is intended for an indoor – general environment.
- It is powered by one CR 2032 lithium battery (3.0 V), with a typical life of approximately 3 years at one activation a day; have the battery replaced by a service engineer.
- Indoor – general environment, operating temperature range −10 °C to +40 °C.
- The neck lanyard must have a mechanical safety release that opens at a load of 40 N or more; a lanyard meeting this specification is included in the package.
Frequently asked questions
The button is intended for indoor spaces: its operating environment is indoor – general. Explain this to the user at handover.
A press triggers a hold-up alarm in the security system. What happens next is determined by the reaction set in the control unit and by the services the customer has agreed, not by the button itself.
Technical specifications
- Power
- lithium battery, type CR 2032 (3.0 V/0.2 Ah)
- Typical battery lifetime
- approx. 3 years (if activated once per day)
- Quiescent current consumption
- 6 µA
- Maximum current consumption
- 40 mA
- Communication band
- 868.1 MHz, Jablotron protocol
- Maximum radio-frequency output (ERP)
- 5 mW
- Communication range
- approx. 300 m (unrestricted area)
- Dimensions (without accessories)
- 41 x 41 x 13 mm
- Weight (without accessories)
- 20 g
- Classification
- security grade 2 /II. Indoor general (in accordance with EN 50131-1)
- Operational environment
- Indoor general
- Ingress Protection Code
- IP 65
- Operating temperature range
- -10 °C to +40 °C
- Average operating humidity
- 75 % RH, without condensation
- Can be operated according to
- ERC REC 70-03
- Certification body
- Trezor Test s.r.o. (No. 3025)
- In compliance with
- ETSI EN 300 220-1,-2, EN 50130-4, EN 55032, EN 62368-1, EN 62311, EN 50581, EN 50131-1, EN 50131-3, EN 50131-5-3, EN 50131-6, EN 50134-2.
Warning
- The button has no tamper contacts; in the project, therefore, base protection against removal on another element.
Installation example
Choose the location: on the wrist as a panic watch, around the neck on the lanyard loop, or on a mounting surface using the holder.
Fix the holder with two 3.5 × 40 mm round-head screws.
In the F-Link program, select a position on the Devices tab and switch on enrolment mode with the Enrol option.
Press and hold the button until the orange LED flashes rapidly and then lights up for a long time (approximately 4 s); the LED lighting up means that the button has sent the enrolment signal and is enrolled to the selected position. It can also be enrolled by entering the serial number from the battery holder below the bar code in the F-Link program.
In the Internal settings of the position, enable or disable visual signalling and, if required, the delayed hold-up alarm.
Check the signal quality on the Diagnostics tab.
Related products

JA-185J
Remote control for car

JA-156J
Wireless multifunctional panic button

JA-159J
Wireless doorbell button

JA-158J
Wireless wall button

JA-152J MS II
Bi-directional two-button keyfob

JA-154J MS II
Bi-directional four-button keyfob

JA-112J
Bus emergency/control wall-mounted button

JA-188JDiscontinued
Wireless panic button

JA-187JDiscontinued
Wireless wrist button
Help us improve the catalog
Missing something, or found a mistake? Let us know.