JA-188J
Wireless panic button
DiscontinuedA wall button for the JABLOTRON system, wireless, with two buttons, A and B, under a movable cover. You select the basic behaviour with a setting switch inside the product, and then the specific reaction in the system. The product is no longer supplied.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K
Check compatibilityKey specifications
- Voltage
- Lithium battery type CR14250 (1/2 AA) 3.6V/1.2 Ah Please note: Battery is not included
- Typical battery lifetime
- approximately 3 years (20 daily activations)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx. 300 metres (open area)
- Dimensions, weight
- 80 x 80 x 29 mm, 60 g
- Operational environment according to
- EN 50131-1 class II. Indoor general
- Operational temperature range
- -10 °C to + 40 °C
Basic description
With the four wall buttons, a single question decides: is there a bus at the location or not? Where there is, the JA-112J belongs. Where there is no cable, you choose between the wireless ones: the JA-158J confirms back that the system has actually carried out the command, the JA-188J is configured with switches directly in its box, and the JA-159J is a doorbell button for an outdoor entrance. What a press should do does not divide the family: hold-up alarm, doorbell and control of appliances are a matter of settings for all of them.
- What the button does is decided by its settings, not by the product type. The very same button can therefore control appliances in one place and trigger an alarm in another.
- It communicates using the JABLOTRON wireless protocol and carries its own power supply. You therefore do not run any cable to the button.
- You select the basic behaviour with a switch inside the product: either the buttons send separate commands A and B, or both send the same command. You then add the reaction to it in F-Link.
- Complies with security grade 2 according to EN 50131-1, EN 50131-5-3 and EN 50134-2.
Why choose this product
What happens after a press
A press has a single task: to send the system a command. What happens next is determined by the reaction assigned to the position to which the button is enrolled in the system, from switching a PG output to triggering an alarm. If the product has two buttons, A and B, each can carry a different reaction; they can also carry the same one, in which case it does not matter which is pressed. A single button always carries only one reaction.
- Triggering a hold-up alarm, remote control of appliances, sounding a doorbell or control of the security system
- The doorbell function needs a siren in the system and a PG output linked to the button; you select the sound in the siren settings
What the system needs for it
The button is a peripheral like any other. In the F-Link program, the position to which the button is enrolled is selected on the Devices tab, and a reaction is assigned to the same position. It can also be enrolled by entering the product's serial number.
- The control unit must be fitted with a JA-11xR radio module
- It can also be enrolled to several receivers at the same time, so it can switch an appliance even outside the control unit
Where it is installed
The bottom part is mounted in the chosen place and the part with the electronics clicks into it so that the tamper sensor spring presses through the hole in the plastic against the surface on which the button is installed. The setting switches must be selected before the cover is closed. If the button is to serve as a hold-up device, it must always be installed with the bottom part and with the tamper sensors enabled.
- Power is supplied by one CR14250 (1/2 AA) 3.6 V lithium battery; typical life is approximately 3 years at 20 activations a day
- Indoor – general environment, −10 °C to +40 °C
- Range approximately 300 m in direct line of sight
Frequently asked questions
It depends on the position of the setting switch. In one position, the buttons send separate commands A and B, so with the Setting reaction one button sets the section and the other unsets it. In the other position, both send the same command, which the system typically turns into a hold-up alarm, or another reaction set in F-Link.
Wherever the system's siren is. The sound is not produced by the button but by the siren to which the activation is linked via a PG output, so the reach of the ringing is the reach of the siren, not of the button. If it needs to be heard in several rooms, this is solved by the number and placement of sirens.
Technical specifications
- Voltage
- Lithium battery type CR14250 (1/2 AA) 3.6V/1.2 Ah Please note: Battery is not included
- Typical battery lifetime
- approximately 3 years (20 daily activations)
- Communication band
- 868.1 MHz, Jablotron protocol
- Communication range
- approx. 300 metres (open area)
- Dimensions, weight
- 80 x 80 x 29 mm, 60 g
- Operational environment according to
- EN 50131-1 class II. Indoor general
- Operational temperature range
- -10 °C to + 40 °C
- Complies with EN 50131-1, EN 50131-5-3, EN 50134-2
- grade 2
- Complies with
- ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
- Can be operated according to
- ERC REC 70-03
Warning
- Select the setting switches before closing the cover. One of them decides whether the buttons send separate commands A and B or both send the same command. A later change means opening the button again.
Installation example
Open the movable cover from the side with a screwdriver.
Release the bottom part by pressing the four latches in the corners.
Mount the bottom part in the chosen place with two Ø 3.5 × 40 mm screws with a countersunk head.
Select the function with the setting switches before closing the cover. When used with a control unit, the switch for the tamper sensors and connection check should be on.
Click the part with the electronics into the bottom part so that the tamper sensor spring presses through the hole in the plastic against the surface on which the button is installed.
In F-Link, select a position on the Devices tab and switch on enrolment mode with the Enrol button.
Insert the battery, observing the correct polarity. This makes the button send the enrolment signal and enrol to the selected position. It can also be enrolled by entering the serial number from the board below the bar code.
If the button previously had a battery connected, first disconnect it, press and release the cover contact to use up the residual energy, and only then enrol the button.
Close the top movable cover of the button.
In F-Link, check the signal of the enrolled button, including its quality, on the Diagnostics tab.
Help us improve the catalog