JA-113E-AN
Bus Access Module with keypad and RFID - anthracite
A bus access module with one control segment, a numeric keypad and a 125 kHz RFID reader. It has no display; status information is provided by the backlit activation button. You can extend the unit with JA-192E segments up to 20 segments in one unit.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Current consumption in standby mode
- 10 mA
- Current consumption for cable selection
- 20 mA
- RFID frequency
- 125 kHz
- Classification
- Grade 2
Basic description
The JA-113E is a bus access module for installations where the number of control elements is put together as needed. It handles control and authorisation in one place, without a display. The display and its convenience are offered by the related JA-114E.
- Each segment does what you need. You assign a segment section control, status signalling, a hold-up alarm or control of a PG output, also inverted.
- Authorisation by code and by tag. A code on the keypad, or a card or tag on the 125 kHz RFID reader.
- Several sections at once with one segment. The Common segment function switches several sections at the same time; you can set up to two on one unit.
Why choose this product
Control and authorisation
The hinged keypad cover can be removed if the user wants permanent access. Authorisation is by a code on the keypad or by holding a contactless card or tag to the RFID reader. Each connected element performs its assigned function: section control, status signalling, a hold-up alarm or a PG output, also inverted. As the module has no display, the system status is provided by the backlit activation button.
- One control segment, a unit of up to 20 JA-192E segments
- 125 kHz RFID reader, authorisation by code or tag
- No more than two common segments, available from three segments upwards
Power supply and installation
Installation is carried out by a trained technician with a valid JABLOTRON certificate.
- Power and communication via the bus, 12 V (9 to 15 V)
- Recommended screw 4× Ø 3.5 × 40 mm with a countersunk head
- Module dimensions 102 × 96 × 33 mm, weight 150 g
Use in the system
Enrolment takes place in F-Link by pressing the backlit activation button, or by entering the full serial number below the bar code.
- The compatibility overview on the website confirms which control units the module works with
- Internal settings and label printing in F-Link, Devices tab
- Security grade 2 with the cover latches secured by screws
Frequently asked questions
By the display. The JA-114E has an information LCD display, the JA-113E does not; the modular architecture, the segments and the RFID reader are the same. Without a display, the JA-113E has a maximum current draw of 20 mA compared with 100 mA for the JA-114E, but status information is only provided by the backlit activation button.
No more than 20 segments in one unit, one of which the module already contains. It is extended with JA-192E segments, which are chained and connected to the connector of the previous segment. The number of segments is not the same as the number of sections: thanks to the Common segment function, one segment can control several sections, and another may only signal.
Contactless cards and tags at 125 kHz. NFC identifiers at 13.56 MHz do not work with this reader. The system can be accessed by code and by tag; the user chooses whichever suits them.
Technical specifications
- Power
- from control panel digital bus (9…15 V)
- Current consumption in standby mode
- 10 mA
- Current consumption for cable selection
- 20 mA
- Each additional control segment
- 0.5 mA
- RFID frequency
- 125 kHz
- Operating temperature range
- -10 °C to +40 °C
- Operational environment according to EN 50131-1
- II Indoor general
- Classification
- Grade 2
- according to
- EN 50131-1, EN 50131-3,
- Also complies with
- ETSI EN 300330, EN 50130-4, EN 55022 EN 60950-1
- Can be operated according to
- ERC REC 70-03
Warning
- The security grade 2 classification only applies with the cover latches secured by the screws supplied; without this, the installation cannot be documented as compliant with EN 50131-3. The module has no display, so you cannot show text information about the system, the name of the section in alarm or the event log on it; choose the JA-114E for that. The Common segment function is only available from three segments in the unit upwards; it cannot be used with the module alone, and at least two JA-192E segments must be added. No more than two common segments can be set on one unit, and combining them with the Section and Common for sections function is not suitable. Segments do not signal in Service mode or with the None function; permanent signalling switches off automatically when a mains power failure is detected. In addition, in Service mode the activation button does not signal activation of the module's tamper contact, so do not rely on a visual tamper check during servicing. Standby current draw is 10 mA, maximum 20 mA. The additional current draw of a full unit is 19 × 0.5 mA, i.e. 9.5 mA, approaching the standby current draw of the module itself; the total current draw of the unit must be calculated. The dimensions and weight apply to the module alone; check the length of the full unit physically before choosing a place on the wall. For a colour variant of the module, choose JA-192E segments in the matching colour. Only connect the bus with the system power completely switched off, and always make changes to the unit with the bus disconnected. The module is not intended for outdoor installation. The environment is indoor – general, −10 to +40 °C and 75 % RH, non-condensing. Installation may only be carried out by a trained technician with a valid JABLOTRON certificate.
Installation example
Always connect the bus with the system power completely switched off.
Release the module from the rear plastic by pressing the four latches on the sides one after another.
When extending the unit, remove the end cap above the first segment.
Remove the transparent covers from the segments by levering them at the side next to the buttons, place the next segment against the previous one and connect its wire to the connector of the previous segment. Coil the wires by turning the segment through 360° so that they do not get pinched between the plastics.
When the unit is complete, refit the end cap.
Screw the rear plastic together with the segments to the chosen place; 4× Ø 3.5 × 40 mm screws with a countersunk head are recommended.
Connect the bus wires to the terminal block and the segment lead to the internal connector of the module.
Click the module into the rear plastic and secure the cover latches with the screws supplied.
Switch on the system power and enrol the module in F-Link by pressing the backlit activation button, or by entering the full serial number below the bar code.
In F-Link, set the functions of the segments, the wake-up of the unit and the acoustic signalling, then print the labels.
Insert the labels into the segment covers and close the covers.
Accessories
Related products

JA-112E
Bus RFID Access Module

JA-113E
Bus Access Module with keypad and RFID

JA-114E
Bus Access Module with display, keypad and RFID

JA-116E
Bus touchscreen keypad with RFID reader

JA-115E
Bus four-segment keypad with display and RFID reader

JA-110E
Bus keypad

JA-120E-WH
Bus outdoor RFID / NFC reader - white

JA-120E-BK
Bus outdoor RFID / NFC reader - black

JA-121E-WH
Bus outdoor keypad with RFID / NFC reader - white

JA-121E-BK
Bus outdoor keypad with RFID / NFC reader - black

JA-122E-NFC
Bus outdoor RFID reader 13.56 MHz

JA-123E-NFC
Bus outdoor keypad with RFID reader 13.56 Mhz
Help us improve the catalog
Missing something, or found a mistake? Let us know.