JA-116H

BUS expander – 16 inputs

Bus expander with sixteen inputs. It powers and connects detectors with contact outputs.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K

Check compatibility

Key specifications

Power supply
12 V (9 … 15 V)
Current consumption (all outputs turned on)
25 mA Warning: the consumptions of the detectors connected to the +U and GND terminals have to be added to the system power backup calculation.
Maximum acceptable load of one output from +U and GND
100 mA
Maximum acceptable load of all outputs from +U and GND
4 x 100 mA
Dimensions
102 x 66 x 20 mm
Weight
80 g
Classification
Security grade 2/Environmental class II

Basic description

The JA-116H is an input module for installations where many wired sensors converge in one place: it handles up to sixteen of them and powers them itself. However, the balancing resistor value is one common choice for all sixteen inputs, and roller shutter mode is offered only by the first half of them; this must be taken into account when laying out the loops. When only a single wired detector needs to be connected, the JA-111H TRB is the right choice; the JA-114HN adds programmable outputs and an auxiliary power supply to the inputs.

  • Sixteen inputs for detectors with a contact output. The expander also powers them.
  • It powers the detectors itself, from four separate groups. Data and power are carried by one bus.
  • Roller shutter and impulse mode on inputs 1 to 8.
  • Security Grade 2 applies only when mounted in an enclosure with a tamper contact.

Why choose this product

Sixteen configurable inputs

Each input is configured according to what is connected to it: as a make or break contact, a single or double balanced loop. However, there is only one choice of balancing resistor and it applies to the whole expander, so all loops must be designed for the same value. Roller shutter and impulse mode are offered only by the first half of the inputs; the second half works in the standard modes.

  • Sixteen inputs for detectors with a contact output
  • Input delay adjustable from 0.5 s to 300 s (from 0.1 s in On mode), 0.5 s by default
  • A maximum of 5 detectors per loop, length up to 100 m

Consumption and positions

The expander itself draws only a little from the bus; what matters is the consumption of the detectors it powers, so their own power input must always be added to the module consumption. In the system, it takes not one place but a contiguous series, one for each of the sixteen inputs.

  • Rated consumption 3 mA, maximum 30 mA
  • Load per power supply group 100 mA, 4 × 100 mA in total
  • Occupies sixteen consecutive positions; at the end of the list, only those remaining

Location and equipment

The expander belongs in a suitable control unit or a certified installation enclosure that provides it with a cover and protection against opening; the classification of the whole assembly depends on this. Also decisive is what the detector offers at its terminals and how much current it draws, because its consumption is carried by the power supply group of the expander.

  • Suitable control unit or JA-194PL installation enclosure, always with a tamper contact
  • An external tamper contact can be brought to any input
  • An LED on the board shows a change on any input