JA-120PW

Bus PIR / MW motion detector

Discontinued

A bus detector, part of the JABLOTRON 100+ system, that combines a PIR part and a microwave part and only sends an alarm after confirmation by both. The PIR coverage angle is 110° and the range 12 m. It is powered via the bus, with no batteries.

Product line

  • JABLOTRON 100+
  • JABLOTRON Mercury

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K

Check compatibility

Key specifications

Power
from the control panel bus 12 V (9 ... 15 V)
Current consumption in standby mode
5 mA
Current consumption for cable choice
25 mA
Recommended installation height
2.5 m above the floor
Detection angle/PIR coverage
110 degrees/12 m (standard lens)
Detection angle/MW coverage
24 degrees/15 m (in open space)
Detection angle/MW coverage
90 degrees/15 m (see the model room)

Basic description

The JA-120PW and JA-180W are older designs of the dual PIR and microwave detector. On the JA-120PW, the immunity level of both the PIR and the microwaves is set in F-Link, and the microwave range with a trimmer potentiometer on the detector. The newer generation with the same principle, in both a more compact and a design version, is represented by the JA-121PW, JA-161PW, JA-122PW and JA-162PW.

  • Confirmed PIR and microwave detection, part of the JABLOTRON 100+ system. An alarm is only triggered after confirmation by both principles; a thermal event on its own does not cause an alarm.
  • Powered from the bus. No batteries and no battery replacement throughout the detector's service life.
  • PIR coverage angle 110° and range 12 m. The microwaves confirm within 24° in open space and approximately 90° in a furnished room, with a range of 15 m.
  • Dual evaluation in one module. Occupies one system position.

Why choose this product

Confirmed dual detection

The PIR part registers movement and activates the microwave part, and the alarm is only sent after confirmation by both. In this way, the detector limits false alarms caused by a change in temperature alone.

  • Power and communication via the bus (12 V)
  • PIR coverage angle 110° / 12 m, microwaves up to 90° in a furnished room / 15 m
  • Occupies one system position

Settings and immunity

You set the immunity of both the PIR and the microwave part to false alarms in F-Link, and the microwave range with a trimmer potentiometer directly on the detector. The tamper contact reports both opening of the cover and removal.

  • PIR and microwave immunity Standard / Enhanced, set in F-Link
  • Microwave range set with a trimmer potentiometer, approximately 1 to 15 m
  • Set the microwave range so that it does not exceed the PIR field of view

Microwave specifics

Microwaves can pick up movement even behind a non-metallic obstacle, such as a thin wall, a door or glass, so limit the range with the trimmer potentiometer so that it does not extend into neighbouring rooms or the corridor.

  • Microwaves pass through non-metallic obstacles (wall, door, glass)
  • Only one microwave detector per room
  • After installation, test the actual coverage

Frequently asked questions