JA-121PW
Bus PIR / MW motion detector
A bus detector, part of the JABLOTRON 100+ system, combining a PIR and a microwave section in a compact design; it only sends an alarm once both confirm it. PIR coverage angle 110° and range 12 m. It is powered via the bus, with no batteries.
Compatibility
JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Power
- from control panel bus 12 V DC (8–15 V)
- Quiescent current consumption
- 2 mA
- Maximal current consumption
- 8 mA
- Recommended installation height
- 2.5 m
- Detection angle / coverage (PIR)
- 110 ° / 12 m
- Detection angle / coverage (MW)
- 80 ° / 12 m
- Operating frequency MW
- 24.125 GHz
Basic description
The JA-121PW and JA-161PW are compact versions of the dual PIR and microwave principle for standard interiors, without the GR/AN versions. Industrial premises and glazed areas are covered by their siblings, the JA-122PW and JA-162PW, with GR/AN versions and support for the JA-191PL bracket.
- Dual PIR and microwave principle, part of the JABLOTRON 100+ system. An alarm is only raised once both principles confirm it; a thermal effect on its own does not cause an alarm.
- Powered from the bus. No batteries and no battery replacement throughout the detector's service life.
- PIR coverage angle 110° and range 12 m. The microwave section confirms within a 90° coverage angle up to 12 m.
- Dual evaluation in one module. Occupies one system position.
Why choose this product
Dual principle: an alarm only when both agree
When the PIR registers movement, the microwave section is activated and confirms it; only when both agree is an alarm raised. A thermal change on its own, such as a draught or sunshine, does not cause an alarm.
- Power and communication via the bus (12 V)
- PIR coverage 110° / 12 m, microwave 90° / 12 m
- Occupies one system position
For demanding environments
The dual principle is suitable where a PIR on its own reports false alarms, for example near heating or in a room with direct sunlight.
- PIR and microwave immunity adjustable in F-Link
- Microwave sensitivity adjustable in F-Link
- The tamper contact reports opening of the cover
Microwave specifics
Microwaves can pick up movement even behind a non-metallic obstacle, so aim the detector away from areas with regular movement behind a partition and carry out a test after installation. Several microwave transmitters close to each other may interfere with each other.
- Microwaves pass through non-metallic obstacles (wall, door, glass)
- Only one microwave detector per room
- Recommended installation height approximately 2.5 m
Frequently asked questions
The detector combines a passive infrared sensor and a microwave sensor. An alarm is only raised on simultaneous detection by both, which reduces the number of false alarms.
In an environment with draughts, heating or direct sunlight, where a PIR on its own reports false alarms caused by thermal effects. The dual principle confirms the movement with a second, independent sensor.
The JA-122PW uses the same dual principle, and in addition offers GR/AN versions with increased immunity to white light and support for the JA-191PL bracket for industrial and glazed areas. The JA-121PW is a more compact design for standard interiors.
Technical specifications
- Power
- from control panel bus 12 V DC (8–15 V)
- Quiescent current consumption
- 2 mA
- Maximal current consumption
- 8 mA
- Recommended installation height
- 2.5 m
- Detection angle / coverage (PIR)
- 110 ° / 12 m
- Detection angle / coverage (MW)
- 80 ° / 12 m
- Operating frequency MW
- 24.125 GHz
- Maximum effective radiated power MW (EIRP)
- <50 mW
- Dimensions
- 60 x 98 x 52 mm
- Weight
- 85 g
- Classification
- security grade 2 / environmental class II (according to EN 50131-1)
- Environment
- indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operating humidity
- 75% RH, non-condensation
- Certification body
- Trezor Test (no. 3025)
- In compliance with
- EN IEC 63000, EN 50130-4, EN 55032, EN 50131-1, -2-4, EN 62368-1, EN ETSI 300 440
- Operating conditions according to general authorization
- ERC REC 70-03
- MW Frequency band according to ERC REC 70-03
- band m)
- ITU designation for MW
- P0N
- ITU designation for SRD
- 80K0F1DAN
- Recommended screw
- 2x ø 3,5 x 40 mm (countersunk head)
Warning
- Always connect the bus with the system power completely switched off. Do not touch the PIR sensor inside, you could damage it. Do not install two microwave detectors in one room; their transmitters would interfere with each other. Microwaves pass through non-metallic obstacles, so carry out a test after installation and reduce the sensitivity if necessary. The cables must not reach behind the partition protecting the microwave sensor.
Installation example
Always connect the bus with the system power completely switched off.
Mount it at a height of 2.5 m; there must be no obstacles in the PIR's view, and metal objects may affect the microwave field.
Open the cover by pressing the latch, do not touch the PIR sensor inside, and take out the electronics.
Screw the rear plastic to the wall and put the electronics back in.
Connect the cable to the terminals, set the PIR and MW immunity and the MW sensitivity in F-Link, then check the coverage.
Close the cover and secure it with the locking screw.
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.