JA-151ST-A-AN
Wireless combined smoke and heat detector with built-in siren - anthracite
When it detects smoke or a high temperature, it starts local signalling and transmits the alarm to the system at the same time.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- 3 x Alkaline battery type LR6 (AA) 1.5 V/2.4 Ah 3 x Lithium battery type FR6 (AA) 1.5 V/3.0 Ah Please note: Batteries are not included
- Typical lifetime
- ≥ 3 years
- Communication band
- 868.1 MHz, Jablotron protocol
- Effective Radiated Power (ERP)
- 10 mW
- Communication range
- approx. 300 m (open area)
- Dimensions
- diameter 126 mm, height 50 mm
- Weight
- 150 g
Basic description
The detector picks up a fire as it starts and gives you time to respond or to evacuate in good time. Besides transmitting the alarm to the system, it also signals the fire on the detector itself.
- Fire signalled locally by the detector itself and also by the system keypads and sirens
- Remote alerting in MyJABLOTRON and to the Alarm Receiving Centre
- Thanks to the heat sensor, it also reacts to a fire without dense smoke (flammable liquids and the like)
Why choose this product
Where the detector can be used
Smoke detection is intended for interiors without increased dust levels, which can cause false alarms. If necessary, the reaction to smoke can be disabled.
- Detection of smoke and of high temperature in residential or commercial buildings
- Optionally a slower reaction to heat only, or both conditions required at the same time
- In enclosed interiors where smoke rises all the way to the ceiling
Placement
The number of detectors depends on the size and layout of the flat or house. The minimum is one detector on the escape route from the flat, plus one more in another part in a flat over 150 m². In a multi-storey flat or family house, a detector belongs above the stairwell as well. Ideally, cover all the rooms where people sleep too.
- If possible the centre of the ceiling, where air circulation carries the smoke
- Parts of a room divided by shelving or partitions reaching almost to the ceiling, each as a separate room
- A narrow space, where the detector belongs in the middle third of its width
Where not to put the detector
Do not place the detector where poor air circulation could prevent smoke from reaching it. At the same time, avoid places with dust, cigarette smoke or steam, where false alarms are a risk.
- In kitchens, bathrooms, laundry rooms or other damp areas
- Directly at air-handling or air conditioning outlets, where the air flow is strong
- In niches, corners and apexes of sloping ceilings, where the air circulates poorly
Frequently asked questions
Optical smoke and heat. The heat part corresponds to class A1, with the option of an A2 configuration reaction. On an alarm it signals locally and reports the alarm to the control unit at the same time.
On the ceiling in natural air circulation, no more than 5 m above the floor and at least 0.5 m away from walls and corners. Avoid dust, steam and fumes.
Monthly, with an aerosol or controlled heat, never with a naked flame. The detector also offers an alarm memory and temporary silencing.
Technical specifications
- Power
- 3 x Alkaline battery type LR6 (AA) 1.5 V/2.4 Ah 3 x Lithium battery type FR6 (AA) 1.5 V/3.0 Ah Please note: Batteries are not included
- Typical lifetime
- ≥ 3 years
- Communication band
- 868.1 MHz, Jablotron protocol
- Effective Radiated Power (ERP)
- 10 mW
- Communication range
- approx. 300 m (open area)
- Dimensions
- diameter 126 mm, height 50 mm
- Weight
- 150 g
- Smoke detection
- optical light scattering
- Smoke detector sensitivity
- m = 0.11 ÷ 0.13 dB/m pursuant to EN 14604:2005, EN 54-7
- Heat detection
- class A1 according to EN 54-5
- Alarm temperature
- +60 °C to +65 °C
- Operating temperature range
- -10 °C to +70 °C
- Complies with
- EN 54-5, EN-54-7, EN-25
- Also complies with
- ETSI EN 300 220-2, EN 50130-4, EN 55022 and EN 60950-1
- Can be operated according to
- ERC REC 70-03
- Recommended screw
- 2x o 3.5 x 40 mm (countersunk head)
Warning
- The detector is not intended for industrial areas or for places with steam, dust or fumes from a kitchen or bathroom. The certified heat class is A1; the A2 reaction is only a configuration option. At temperatures below 5 °C use lithium cells, and never use a naked flame for testing.
Installation example
Choose a place on the ceiling in natural air circulation, no more than 5 m above the floor and at least 0.5 m away from walls and corners.
Fix the detector with four screws and insert three AA batteries of the same type.
Enrol the detector according to the control unit manual.
To comply with the standards, secure the cover with the screw.
Carry out a test with an aerosol or with controlled heat, never with a naked flame.
Accessories
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer
Help us improve the catalog
Missing something, or found a mistake? Let us know.