JA-122PW-AN
Bus dual PIR and MW motion detector - anthracite
A bus detector, part of the JABLOTRON 100+ system, combining a PIR and a microwave section; it only sends an alarm once both confirm it. PIR coverage angle 110° and range 12 m. The GR and AN versions increase immunity to white light.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Power supply
- from the control panel bus 12 V DC (9 ... 15 V)
- - in standby mode
- 5 mA
- - for cable choice
- 16 mA
- Recommended installation height
- 2.2 – 2.5 m above floor level
- Detection angle/PIR coverage
- 90°/12 m
- Detection angle/MW coverage
- 80°/12 m
- MW Frequency
- 24.125 GHz
Basic description
The JA-122PW and JA-162PW use the same dual principle as the JA-121PW and JA-161PW, and in addition offer versions with a grey (GR) and black (AN) lens for immunity to white light, and support for the JA-191PL articulated bracket. Choose them for industrial halls, warehouses or glazed areas where the compact version is not enough.
- Dual PIR and microwave principle, part of the JABLOTRON 100+ system. An alarm is only raised once both principles confirm it; a thermal effect on its own does not cause an alarm.
- Powered from the bus. No batteries and no battery replacement throughout the detector's service life.
- PIR coverage angle 110° and range 12 m. The microwave section confirms within a 90° coverage angle up to 12 m.
- Dual evaluation in one module. Occupies one system position.
Why choose this product
Dual principle: an alarm only when both agree
When the PIR registers movement, the microwave section is activated and an alarm is only raised when both agree. Halls with temperature fluctuations or areas near heating therefore do not cause an alarm from a thermal change alone.
- Power and communication via the bus (12 V)
- PIR coverage 110° / 12 m, microwave 90° / 12 m
- Occupies one system position
For industrial and glazed environments
The dual principle is suitable for halls, warehouses and areas with temperature fluctuations, where a PIR on its own reports false alarms.
- PIR and microwave immunity adjustable in F-Link
- Microwave sensitivity adjustable in F-Link
- Can be combined in one system with its sibling, the JA-121PW
Versions and immunity to light
The versions with a different lens extend use to areas with strong daylight, where the white version could have lower immunity to false alarms caused by glare.
- White version: immunity to white light up to 6,000 lux
- GR/AN versions: immunity to white light up to 10,000 lux
- Support for the JA-191PL articulated bracket
Frequently asked questions
The detector combines a passive infrared sensor and a microwave sensor. An alarm is only raised on simultaneous detection by both, which reduces the number of false alarms.
In an environment with draughts, heating or direct sunlight, where a PIR on its own reports false alarms caused by thermal effects. The dual principle confirms the movement with a second, independent sensor.
The JA-121PW uses the same dual principle in a more compact design without the GR/AN versions. The JA-122PW additionally offers versions with increased immunity to white light and support for the JA-191PL bracket for industrial and glazed areas.
Technical specifications
- Power supply
- from the control panel bus 12 V DC (9 ... 15 V)
- - in standby mode
- 5 mA
- - for cable choice
- 16 mA
- Recommended installation height
- 2.2 – 2.5 m above floor level
- Detection angle/PIR coverage
- 90°/12 m
- Detection angle/MW coverage
- 80°/12 m
- MW Frequency
- 24.125 GHz
- Maximum MW radio-frequency power (ERP)
- 30 mW
- Dimensions
- 150 x 63 x 40 mm
- Weight
- 120 g
- Classification
- Security grade 2/Environmental class II (According to EN 50131-1)
- Environment
- Indoor general
- Operating temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, w/o condensation
- Certification body
- Trezor Test s.r.o. (no. 3025)
- In compliance with
- ETSI EN 300 440, EN 50130-4, EN 55032, EN 62368-1, EN 50581, EN 50131-1, EN 50131-2-4
- Operating conditions according to general authorization
- ERC REC 70-03
Warning
- Always connect the bus with the system power completely switched off. Do not touch the PIR sensor inside, you could damage it. Do not install two microwave detectors in one room; their transmitters would interfere with each other. Microwaves pass through non-metallic obstacles, so carry out a test after installation. The cables must not reach behind the partition protecting the microwave sensor.
Installation example
Always connect the bus with the system power completely switched off. It is best mounted in a corner of the room, at a height of no more than 2.5 m above the floor.
Open the cover by pressing the latch, do not touch the PIR sensor inside, and take out the electronics. The cables must not reach behind the partition protecting the microwave sensor.
Screw the rear plastic to the wall, put the electronics back in and connect the cable to the terminals.
Set the PIR and microwave immunity in F-Link according to the area and carry out a test.
Close the cover and secure it with the locking screw.
Related products

JB-110N
Bus PG power output module

JA-111TH
Bus temperature detector

JA-112P
Bus PIR motion detector

JA-110P
Bus PIR motion detector

JA-110P PET
Bus PIR motion detector with basic pet immunity

JA-115P
Bus ceiling PIR motion detector

JA-122PW
Bus dual PIR and MW motion detector

JA-122PB
Bus combined PIR motion and glass break detector

JA-122PC
Bus combined PIR motion detector with 90° photoverification camera

JA-120PC (90)
Bus PIR motion detector with 90° photo-verification camera

JA-120PC
Bus PIR Motion Detector with Camera

JA-111M
Mini bus magnetic detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.