JA-152A

Wireless internal siren for an AC socket

Indoor wireless siren for a mains socket, with no fixed supply and no drilling. It signals an alarm by sound inside the building with an acoustic pressure of 100 dB/1 m and also handles supplementary acoustic indication: entry and exit delays, programmable outputs or a doorbell. Its back-up battery is factory-connected and it is classified as a type Y warning device with 24 h backup.

Product line

  • JABLOTRON 100+
  • JABLOTRON Mercury

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY

Check compatibility

Key specifications

Power
230 V AC, 50-60 Hz; protection class II
Supply voltage range
90 - 253 V AC
Nominal current
4 mA
Maximum current
13 mA
Backup battery/lifetime
3.2 V, 400 mAh (BAT-3V2-CR2) / 3 years
Backup battery/minimum voltage when loaded
3.0 V
Backup battery/maximum voltage when unloaded
3.6 V

Basic description

The JA-152A is an indoor siren for a mains socket: it needs no fixed supply, no drilling into the wall and no electrical qualification, and you can move it to another socket within range of the system radio at any time. Where the siren is to hang on the wall with a fixed 110 to 230 V AC supply, the family includes the JA-150A II, and where there is neither a supply nor a free socket, the battery-powered JA-154A steps in. The JA-152A shares the acoustic pressure of 100 dB/1 m and the classification as a type Y warning device with 24 h backup with the JA-150A II, and adds IP40 ingress protection and IK08 mechanical impact resistance.

  • Audible alarm signalling inside the building. Press the control button to silence the alarm, and the system records that someone is present.
  • Plug it into a mains socket, with no drilling and no fixed supply. The 90 to 253 V AC range copes even with an unstable mains supply, and during a power failure it keeps running from the back-up battery.
  • Acoustic pressure during an alarm 100 dB/1 m. IP40 ingress protection and IK08 mechanical impact resistance, indoor environment −10 to +40 °C.
  • Occupies one position in the system and requires a JA-11xR radio module in the control unit. An accelerometer detects removal from the socket and reports it as tamper.

Why choose this product

Sound for alarms and everyday operation

The siren sounds in the sections you assign to it and, by default, responds to the internal warning signal IW; it can be switched to the external warning EW. Alarm sounding can be disabled without the siren losing its other indications. It can distinguish a fire alarm by fast beeping, matching the smoke detectors. By default, pressing the control button silences the alarm and reports that someone is present; in F-Link it can be assigned a different function, such as a silent hold-up alarm in the assigned section.

  • Acoustic pressure during an alarm 100 dB/1 m
  • TEST button with a three-second sound signal in response
  • Sounding of programmable outputs and four doorbell melodies

A socket instead of a fixed supply

The siren plugs directly into a mains socket, so there is no need for a fixed supply or drilling into the wall, and you can move it elsewhere at any time. However, it occupies the socket permanently, and behind furniture or in concealed spots, the propagation of both sound and the radio signal deteriorates. If the battery voltage drops to a critical level, the battery is disconnected from the electronics and from that moment the siren is out of operation; when powered from the mains, it works fully even with a flat battery and only drops out during a mains failure. The replacement is carried out by a trained technician in service mode with the siren unplugged from the socket.

  • Powered from the socket, range 90 to 253 V AC, rated consumption 4 mA, maximum 13 mA
  • Back-up battery factory-connected, type Y with 24 h backup
  • IP40 ingress protection and IK08 impact resistance, indoor environment −10 to +40 °C

Enrolment, tamper and settings

The siren is an addressable peripheral that you enrol in F-Link on the Devices tab using Enrol and a short press of the control button. In Internal settings, you then define the sections, reaction, signalling duration, volume of the supplementary acoustic indication and the sounding of programmable outputs. Opening the cover is permitted only in service mode and is monitored by the rear protective contact. For a certified installation, apply the settings in one step with the EN 50131 system profile.

  • Occupies one position in the system, range approximately 300 m in line of sight
  • Requires a JA-11xR radio module in the control unit
  • The accelerometer reports removal from the socket; options No, Always and At alarm

Frequently asked questions

Help us improve the catalog. Missing something, or found a mistake? Let us know.