JA-113A
Bus external siren
It indicates alarms and other events acoustically as well as visually. It attracts the attention of those nearby and deters offenders. Security Grade 3.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Power
- from the control panel bus 12 V (8–15 V)
- Back-up battery
- NiMH, type BAT-4V8-LH1800 / 4.8 V / 1800 mA (NiCd type BAT-4V8 / 4.8 V / 1800 mA can be connected also) Note: Back-up battery is not included, optional fitting, However, mandatory for compliance with the GRADE 3 system profile!
- Typical back-up battery lifetime
- approx. 5 years
- Low back-up battery voltage
- <4.6 V
- Quiescent current consumption from the bus
- 2.5 mA
- Maximum current consumption from the bus
- 500 mA
- Quiescent current consumption from the back-up battery
- 3.6 mA
Basic description
A siren installed visibly on the façade acts above all as a preventive measure. If the offender nevertheless decides to break into the premises, the loud sounding and the intense flashing attract attention that cuts their stay to a minimum.
- Various colours and cover materials to blend in with the exterior
- Optionally red or blue flashing during an alarm, and a flash at regular intervals for a preventive effect
- Supplementary indication when guarding and programmable outputs are controlled
- The option of operation without a rechargeable battery
Why choose this product
Individual composition
The siren cover is sold separately. The plastic version is available in a white, grey or anthracite version with a transparent LED light guide, and the flashing colour is chosen in the settings. The stainless steel cover is available separately with a red or a blue flasher. The siren can also be installed without a back-up battery (it then meets neither security grade 2 nor 3, has a reduced acoustic power and a higher consumption from the bus).
- JA-1x2A-C-WH / JA-1x2A-C-GR / JA-1x2A-C-AN plastic covers
- JA-1X1A-C-ST / JA-1X1A-C-ST-B stainless steel covers
- BAT-4V8-LH1800 back-up battery for full power and for meeting Security Grade 2/3
Wide-ranging indication options
Besides the alarm sounding, a quieter supplementary indication is also available. The siren can therefore confirm control by a remote control, warn that unsetting is needed after entering the perimeter, or beep when the entrance gate is opened.
- Indication of the entry / exit delay
- Confirmation of unsetting / setting
- Configurable sound for activation of a programmable output
Frequently asked questions
Whenever the installation is to meet Security Grade 3 or compliance with EN 50131-1; in both cases a rechargeable battery fitted is a condition. With a back-up battery, the siren also sounds and flashes for 3 minutes if the supply cable is interrupted or communication with the control unit is lost. Otherwise it sounds directly from the bus, so allow for the maximum consumption of 500 mA when sizing, and always run the Function test in F-Link.
The JA-1X2A-C covers in white, grey and anthracite have a transparent LED light guide, and the assembly with them measures 200 × 300 × 62 mm. With older covers of the JA-1X1A-C range, with which compatibility is retained, the assembly measures 200 × 300 × 72 mm. Technically it is the same siren; the cover adapts the appearance to the façade and determines the colour of the LED light guide, which you then select in F-Link.
If the bus voltage disappears, that is after a long power failure and the control unit rechargeable battery being exhausted, the siren starts to flash and sound. Allow for this during servicing and when talking to the user, so that such a reaction does not look like a fault. In Service mode, signalling of a communication failure with the control unit is not triggered.
Technical specifications
- Power
- from the control panel bus 12 V (8–15 V)
- Back-up battery
- NiMH, type BAT-4V8-LH1800 / 4.8 V / 1800 mA (NiCd type BAT-4V8 / 4.8 V / 1800 mA can be connected also) Note: Back-up battery is not included, optional fitting, However, mandatory for compliance with the GRADE 3 system profile!
- Typical back-up battery lifetime
- approx. 5 years
- Low back-up battery voltage
- <4.6 V
- Quiescent current consumption from the bus
- 2.5 mA
- Maximum current consumption from the bus
- 500 mA
- Quiescent current consumption from the back-up battery
- 3.6 mA
- Maximal current consumption from the back-up battery
- 800 mA
- Type of warning device
- type Z
- Acoustic siren performance
- 100 dB/m (new back-up battery)
- Dimensions with cover type JA-1X1A-C-XX-X
- 200 x 300 x 72 mm
- Dimensions with cover type JA-1X2A-C-XX
- 200 x 300 x 62 mm
- Weight (without back-up battery)
- 413 g
- Classification
- Security grade 3 / environmental class IV (according to EN 50131-1)
- Environment
- outdoor general
- Operating temperature range
- -25 °C to +60 °C
- Certification body
- Trezor Test s.r.o. (no. 3025), Kiwa Nederland b. v.
- Average operating humidity
- 75% RH, non-condensation
- Complies with
- EN 50130-4, EN 55032, EN IEC 62368-1, EN IEC 63000, EN 50131-4, T 031
- Recommended screw
- 2x ø 4.5 x 50 mm (countersunk head)
Warning
- The JA-113A-BASE-RB base cannot be used on its own; always complete it with one of the outer covers. The base and the cover are ordered separately. With covers of the JA-1X2A-C range, the assembly measures 200 × 300 × 62 mm; with older covers of the JA-1X1A-C range, 200 × 300 × 72 mm. Order the BAT-4V8-LH1800 or BAT-4V8 back-up battery separately and do not use any other type. Security Grade 3 applies only with the back-up battery fitted, and connecting it is required for compliance with EN 50131-1 as well. Signalling of a communication failure with the control unit works only with a back-up battery. The maximum consumption from the bus is 500 mA; take it into account when sizing the power supply, especially in an installation without a back-up battery. In an installation without a rechargeable battery, or on a line with a greater voltage drop, we recommend adding a rechargeable battery and always running the Function test in F-Link. The acoustic pressure of 100 dB/1 m applies with a new battery; the acoustic power of the siren can damage your hearing, so take extra care when handling it. Mount it only on a vertical wall with the LED light guide facing down, not near gutters or where there is a risk of ice forming. Always close the cover fully and secure it with the screw; a partly closed cover leads to incorrect calibration of the magnetic sensor and to a tamper being reported. The rear tamper sensor is calibrated two minutes after the power supply is connected. Select the LED colour in F-Link to match the colour of the LED light guide of the cover purchased. Replace the rechargeable battery only in Service mode, otherwise the siren will report a tamper alarm, and use only BAT-4V8 or BAT-4V8-LH1800. Connect the bus only with the system power supply completely switched off, and bear in mind that the connector of the electroacoustic transducers is at high voltage. Installation may only be carried out by a trained technician with a valid JABLOTRON certificate.
Installation example
Always connect the bus with the system power completely switched off. The connector of the electroacoustic transducers is at high voltage, and the acoustic power of the siren can damage your hearing.
Pull the bus cable through the opening and press it into the retaining clips.
Screw the siren onto a vertical wall with two 2× Ø 4.5 × 50 mm screws with a countersunk head, with the LED light guide facing downwards; level the vertical position using the built-in spirit level.
Connect the bus cable to the terminals.
Connect the back-up battery to the connector; connecting it is required for compliance with EN 50131-1.
After the system is switched on, the yellow LED flashes to indicate that the siren has not been enrolled into the system.
In F-Link, on the Devices tab, select the position, start Scan/add new BUS devices with the Enrol option and enrol the siren with a double click; the yellow LED goes out.
Check the connection of the electroacoustic transducers to the connector on the printed circuit board.
Connect the cover lanyard with the clip, fit the cover chosen and secure it with the locking screw; close the cover fully.
For an installation without a rechargeable battery, run the Function test in F-Link and verify the power supply.
In Internal settings, set the acoustics, the visual signalling, the Installation with back-up battery parameter and the signalling of programmable outputs.
Select the LED colour to match the colour of the LED light guide of the cover purchased.
Related products

JA-108K
Control panel JA-108K

JA-116E
Bus touchscreen keypad with RFID reader

JA-113M
Bus magnetic detector with recognition of external magnetic fields

JA-113M-AN
Bus magnetic detector with recognition of external magnetic fields - anthracite

JA-113M-GR
Bus magnetic detector with recognition of external magnetic fields - grey

JA-116E-AN
Bus touchscreen keypad with RFID reader - anthracite

JA-116E-GR
Bus touchscreen keypad with RFID reader - grey

JA-110A
Bus internal siren

JA-110A II
Bus internal siren with battery back-up

JA-111A
Bus external siren

JA-112I
Bus section/output PG activation indicator

JA-111H TRB
Bus module interface for wire detector
Help us improve the catalog
Missing something, or found a mistake? Let us know.