JA-112I

Bus section/output PG activation indicator

Bus optical indicator that reads the status directly from the bus. With eight configuration switches on the board, you specify which section or which programmable output it is to display. It then shows the status with a red LED.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K

Check compatibility

Key specifications

Power
from control panel BUS 12 V DC (9…15 V)
Standby power consumption (LED on/off)
6 mA/3 mA
Current consumption for cable selection
5 mA
Dimensions
62 x 36 x 27 mm,
Weight
26 g
Operational environment
indoor general
Operational temperature range
-10 °C to +40 °C

Basic description

The two indicators differ in where they take their status information from, and that is decisive when choosing. The JA-112I reads it directly from the bus: with the switches on the board, you assign it section 1 to 16 or programmable output PG 1 to 128, which it then displays by itself. The JA-111I is controlled exclusively by what you bring to its terminals; each of its four colours lights up when the corresponding input is switched to GND, so an output, relay or contact must be ready in the installation for each colour. Therefore choose the JA-112I where the light is to show the status of a single section or programmable output, and the JA-111I where you need several colours and already have the switching signals available.

  • Shows the status of a single section or programmable output. Select section 1 to 16 or PG 1 to 128 with eight switches on the board.
  • Powered via the 12 V bus, range 9 to 15 V. Consumption 6 mA with the LED lit and 3 mA when off.
  • It is not enrolled to the system and occupies no position. The number of indicators is limited only by the available bus current.

Why choose this product

Indication of a section or programmable output

The indicator reads the status directly from the bus, so a connection to the bus is all it needs for the display. What it is to show is selected directly on the board, not in the configuration software. Several indicators set in the same way light identically, so the same status can be shown in several places in the building.

  • Section 1 to 16 or programmable output PG 1 to 128
  • Selection with eight configuration switches on the board
  • Indication is provided by a red LED

Powered via the bus

A single bus line brings both current and status information, so all you need to bring to the indicator is the bus. The number of units in the system is limited not by the number of positions but by the current balance of the bus; how many indicators you can afford therefore follows from the current budget remaining on the bus. A lit LED slightly increases consumption, and that is exactly what the design must take into account.

  • Powered via the 12 V bus, range 9 to 15 V
  • Consumption 6 mA with the LED lit, 3 mA when off
  • Connection to the BUS terminals

Location and use

The indicator is not enrolled to the system, so the project does not need to consider whether a free position is left for it; the only ceiling is the current budget of the bus. It is placed where the status is to be visible, and it belongs inside, not on a façade.

  • Indoor environment, −10 to +40 °C, average operating humidity 75% RH, non-condensing
  • If the indicator is outside the protected area, separate the bus supply with a JA-110T isolator
  • Dimensions 62 × 36 × 27 mm, weight 26 g