JA-110A
Bus internal siren
Indoor bus siren with a piezoelectric transducer and an acoustic pressure of 85 dB/1 m. It signals an alarm by sound inside the building and also handles supplementary acoustic indication: entry and exit delays, programmable outputs or a doorbell with four melodies. It is addressable, occupies one position in the system and is powered from the control panel bus.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Power supply/wattage
- 12V (9…15 V), from the BUS
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice
- 30 mA
- Siren
- piezo-electric, 85 dB/m
- Dimensions
- 80 x 80 x 25 mm
- Classification
- security grade 2
- - According to
- EN 50131-1, EN 50131-4
Basic description
The JA-110A is the basic indoor siren of the pair and suits places where the system is to signal an alarm by sound inside the building and sound everyday operation. The JA-110A II is 15 dB louder, has a maximum current consumption of 120 mA for dimensioning the power supply, a 3.2 V LiFePO4 battery with a capacity of 0.4 Ah and the classification of a type Z warning device with 24 h backup; choose it where the project requires any of these parameters. Visual warning outside the building is provided by the JA-113A outdoor siren with an LED light guide and two-colour LEDs.
- Signals an alarm by sound inside the building. The piezoelectric transducer delivers an acoustic pressure of 85 dB/1 m.
- Power and communication via the bus. Nominal 12 V DC within the range 9 to 15 V, rated consumption 5 mA and maximum 30 mA.
- You can also add it to a system that is already installed.
- It also serves as a doorbell. For each programmable output, choose beeping, a twenty-second signal or one of four melodies.
Why choose this product
Alarm signalling and the siren button
The siren sounds during an alarm in the selected sections, by default in all of them. By default, it responds to the internal warning signal IW; it can be switched to the external warning EW, or alarm sounding can be disabled completely while the other functions are retained. It can distinguish a fire alarm by fast beeping, the same as smoke detectors with an internal siren. Pressing the siren silences the alarm and the system sends a report that someone is present in the building; in F-Link, this reaction can be changed, for example to sending a hold-up alarm. With the same press, the user changes the volume of the supplementary acoustic indication if the By button mode is selected.
- Piezoelectric transducer, acoustic pressure 85 dB/1 m
- Siren time limited to 1 to 5 minutes or according to the alarm length from the control unit
- Four doorbell melodies and sounding of programmable outputs
Powered from the control panel bus
The siren is powered and communicates via the control unit bus, so no separate power supply cable or power supply of its own leads to it. The same line carries commands and siren status reports.
- Bus 12 V DC within the range 9 to 15 V, rated consumption 5 mA
- Maximum current consumption 30 mA
- Indoor warning device, type X
Location and indoor installation
The siren is intended for an indoor – general environment and is mounted inside the building. It is fixed directly to the wall surface or onto an electrical installation box, so it can be integrated into the existing electrical installation. The bus cable is passed through a knock-out opening in the base, which is screwed to the wall; the middle frame is then fitted back on and the siren body inserted into it so that the tamper sensors lie above the magnets. The front protective contact monitors removal of the body, the rear contact pulling off the wall. The siren is an addressable peripheral that you enrol in F-Link by selecting a position, pressing its button or entering the serial number.
- Occupies one position in the system
- Range −10 to +40 °C, humidity 75% RH, non-condensing
- Security Grade 2, environmental class II, dimensions 80 × 80 × 28 mm
Frequently asked questions
Yes. Alarm sounding can be disabled completely in F-Link and the other functions remain active, so the siren continues to sound entry, exit, section control, warnings, programmable outputs and the doorbell. The reaction can also be switched from the internal warning IW to the external warning EW, or only some sections can be selected for which the siren sounds.
The JA-113A outdoor siren. It has an LED light guide with two-colour LEDs, its idle flashing shows that the building is equipped with a working security system, and it signals an alarm by both sound and light outside the building. The JA-110A remains the acoustic signalling inside the building: it alerts people on site and also handles entry delay, programmable outputs and the doorbell.
Technical specifications
- Power supply/wattage
- 12V (9…15 V), from the BUS
- Current consumption in standby mode
- 5 mA
- Current consumption for cable choice
- 30 mA
- Siren
- piezo-electric, 85 dB/m
- Dimensions
- 80 x 80 x 25 mm
- Classification
- security grade 2
- - According to
- EN 50131-1, EN 50131-4
- Operational environment according to
- EN 50131-1 II. Indoor general
- Operating temperature range
- -10 °C to +40 °C
- Also complies with
- EN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN IEC 63000, EN 62368-1
- Certification body
- Trezor Test s.r.o.
Warning
- Always connect the bus with the system power completely switched off. Mount the siren inside the building, in an indoor – general environment of class II, within the range −10 to +40 °C and at humidity of up to 75% RH, non-condensing. For signalling outside the building, use the JA-113A outdoor siren with an LED light guide. When inserting the body, the tamper sensors must lie above the magnets, otherwise the siren reports tamper. The volume setting of the supplementary acoustic indication has no effect on the alarm volume. Installation may only be carried out by a trained technician holding a valid JABLOTRON certificate.
Installation example
Always connect the bus with the system power completely switched off.
Prise the siren body out of the plastic frame with a flat screwdriver in the vertical slot.
Remove the middle part of the frame by pressing the four latches.
Break out the knock-out opening in the base and pass the bus cable through it.
Screw the base to the wall surface or onto an electrical installation box with 2× Ø 3.5 × 40 mm flat head screws.
Fit the middle frame back onto the base.
Connect the bus cable to the terminal block.
Insert the siren body back into the frame so that the tamper sensor lies above the magnet in the base; when mounting on an installation box without the base, move the magnet into the siren frame.
In F-Link, select a position on the Devices tab, start enrolment mode using Enrol and press the siren (at the top or bottom); the yellow LED goes off.
In Internal settings, set the sections, reaction, siren time, volume and signalling of programmable outputs.
Related products

JA-110A II
Bus internal siren with battery back-up

JA-111A
Bus external siren

JA-113A
Bus external siren

JA-112I
Bus section/output PG activation indicator

JA-163A
Wireless outdoor battery powered siren

JA-154A
Wireless battery indoor siren

JA-152A
Wireless internal siren for an AC socket

JA-1X2A-C-WH
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - white, transparent light guide

JA-1X2A-C-AN
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - anthracite, transparent light guide

JA-1X2A-C-GR
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - grey, transparent light guide

OS-350
Siren

OS-365A
Outdoor siren
Help us improve the catalog
Missing something, or found a mistake? Let us know.