JA-154A

Wireless battery indoor siren

Indoor wireless siren powered by three LR6 batteries, with no power supply cable and no socket. It sounds during an alarm and also sounds programmable outputs, section control and entry and exit delays; a backlit LED light guide shows its status. Place it anywhere within range of the system radio; the maximum acoustic power is 85 to 88 dB.

Product line

  • JABLOTRON 100+
  • JABLOTRON Mercury

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY

Check compatibility

Key specifications

Power
3x Alkaline battery, type LR6 (AA) 1.5 V/2.45 Ah Batteries are not included in the packaging.
Typical lifetime of batteries
approx. 2 years
LowBatt state
<3,3 V
Quiescent current consumption
135 µA
Maximum current consumption
250 mA
Current consumption during acoustic indication
250 mA
Communication frequency
868.1 MHz, JABLOTRON protocol

Basic description

The JA-154A is an indoor siren powered by three LR6 batteries, so it needs neither a fixed supply nor a socket and you can place it anywhere within range of the system radio. Where there is a free socket, the family includes the JA-152A, and where the siren is to hang on the wall with a fixed 110 to 230 V AC supply, the JA-150A II; both have an acoustic pressure of 100 dB/1 m and the classification of a type Y warning device with 24 h backup. The JA-154A has a maximum acoustic power of 85 to 88 dB and is classified as a type W warning device, so it is suitable as a supplementary indoor siren for places the sound of the main siren does not reach.

  • Audible alarm signalling inside the building, complemented by an LED light guide. It lights red during an alarm and yellow during a communication failure or in service mode.
  • Powered by three LR6 (AA) alkaline batteries instead of a supply cable or socket. Place it anywhere within range of the system radio; the typical lifetime of batteries is 2 years.
  • Maximum acoustic power 85 to 88 dB. Indoor – general environment, −10 to +40 °C.
  • It is enrolled to a peripheral position and requires a JA-11xR radio module in the control unit. Configure it in F-Link or in the mobile app.

Why choose this product

Sound for alarms and everyday operation

The siren sounds in the sections you assign to it and, by default, responds to the internal warning signal IW; it can be switched to the external warning EW. Alarm sounding can be disabled without the siren losing its other indications. It can distinguish a fire alarm by fast beeping, matching the smoke detectors. You can also enable visual signalling via the LED light guide for warnings and section control; the volume of the supplementary acoustic indication is set in levels and can be programmed for a time interval at full volume. Alarm signalling always has the highest priority and interrupts any lower-priority indication.

  • Maximum acoustic power 85 to 88 dB
  • Siren time 1 to 5 minutes or for the duration of the alarm, up to 20 minutes depending on the control unit
  • Sounding of programmable outputs PG 1 to 32, four melodies to choose from

Batteries instead of a power supply cable

Power from AA cells frees the installation from cables and sockets, so you place the siren where it needs to be heard, not where the electricity runs. Battery life, however, depends on the settings: supplementary acoustic indication, visual signalling and longer sounding all shorten it, and the for-the-duration-of-the-alarm option lets the siren sound for the whole time the control unit holds the alarm. The siren reports approaching discharge in advance, so replacement can be planned. Before replacement, switch the system to Maintenance or Service mode, otherwise the siren triggers a tamper alarm. The intended environment is indoor – general.

  • Power supply 3× LR6 (AA) alkaline battery, 1.5 V, 2.45 Ah
  • Batteries are not included; order them separately
  • Typical lifetime of batteries 2 years, consumption 135 µA, 250 mA when sounding

Enrolment, tamper and settings

The siren is enrolled to a peripheral position, and the control unit must have a JA-11xR radio module for this. The order of steps is fixed: first start enrolment mode on the Devices tab and only then insert the batteries; the siren then appears in the selected position. The settings are divided into tabs for acoustics, signalling of programmable outputs and visual signalling, and you can make them in F-Link as well as in the mobile app. Secure the front part with the locking screw; without it, you will not meet the relevant security grade. In addition, in the profile according to EN 50131, reporting of a communication failure with the control unit is permanently enabled and can no longer be disabled.

  • Communication at 868.1 MHz, maximum RF power ERP 25 mW
  • Cover tamper contact; alarm when opened outside Maintenance and Service mode
  • Reports a communication failure by sounding after 110 minutes if the signalling is enabled; always in the EN 50131 profile

Frequently asked questions

Help us improve the catalog. Missing something, or found a mistake? Let us know.