JA-111H TRB

Bus module interface for wire detector

BUS module for connecting a wired detector to the JABLOTRON 100+ system. It supplies the detector with power and transmits its alarm, tamper and fault or anti-masking. Occupies one system position.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K

Check compatibility

Key specifications

Power
from control panel bus 12 V DC (8...15 V)
Quiescent current consumption
5.2 mA (+ consumption of connected devices, all inputs connected to GND)
Maximal current consumption
11 mA (+ consumption of connected devices)
Maximum allowed current of the connected detector
50 mA
Type of control device (ACE)
type B
Dimensions
18.1 x 31.5 x 12 mm
Wire length
300 mm (cannot be extended)

Basic description

The JA-111H TRB connects a wired detector, i.e. a device that reports its status, to the JABLOTRON 100+ bus and powers it at the same time. Devices that are used to control the system are connected by the JA-111H-AD TRB module instead. Where several wired inputs are to be added to the bus at once, the JA-114HN or JA-116H is the right choice; the JA-162M brings them in wirelessly.

  • Connects a wired detector that reports its status. Alarm, tamper and fault or anti-masking.
  • Power and transmission over one bus. The module also powers the connected detector.
  • Dimensions 18.1 × 31.5 × 12 mm. It fits directly inside the detector.
  • Security Grade 3 applies only in a Grade 3 housing and with the corresponding control unit profile.

Why choose this product

Connecting a wired detector

The module turns a wired detector into a full-fledged bus peripheral: it reports to the control unit under its own address and behaves in the same way as a bus device. How each wire is to react is set in the configuration software according to the task and the selected security profile of the system. The yellow LED indicates a fault or an unenrolled peripheral; the red one flashes at each activation.

  • INP, TMP and TRB inputs for alarm, tamper and fault
  • The INP input handles both status and impulse behaviour
  • Roller shutter mode for the CT-01 sensor and control of programmable outputs

Power supply and connecting wires

The module takes its power from the control unit bus and passes part of it on to the connected detector. One bus thus carries both data and current, and no separate power supply line needs to run to the detector. Therefore check how much current the detector draws before you connect it to the module.

  • Rated consumption 5.2 mA, maximum 11 mA
  • Output load 50 mA maximum
  • Wires 300 mm, cannot be extended

Purpose and conditions

The classification is not given by the module itself but by the whole assembly. Three things come together in it: the housing into which the module is built, the configured control unit profile and the behaviour of the connected detector. The assembly then meets only what the weakest of the three can sustain.

  • Connects a detector with contact or pulse outputs
  • Mounted inside a wired detector or in a protected installation box
  • TRB input delay fixed at 0.1 s in Grade 3

Frequently asked questions