JA-162PW-AN
Wireless dual PIR and MW motion detector - anthracite
A wireless detector, part of the JABLOTRON 100+ system, combining a PIR and a microwave section; it only sends an alarm once both confirm it. PIR coverage angle 110° and range 12 m. The GR and AN versions increase immunity to white light.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power supply
- 2x lithium battery, type: CR123A (3 V/1500 mAh) Please note: Batteries are not included.
- Typical lifetime of batteries
- 4 Years
- LowBatt state
- < 2,7 V
- Quiescent current consumption
- 65 µA
- Maximum current consumption
- 50 mA
- Communication band
- 868,1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- 25 mW
Basic description
The JA-122PW and JA-162PW use the same dual principle as the JA-121PW and JA-161PW, and in addition offer versions with a grey (GR) and black (AN) lens for immunity to white light, and support for the JA-191PL articulated bracket. Choose them for industrial halls, warehouses or glazed areas where the compact version is not enough.
- Dual PIR and microwave principle, part of the JABLOTRON 100+ system. An alarm is only raised once both principles confirm it; a thermal effect on its own does not cause an alarm.
- Installation without cables. Battery-powered; installation requires no cabling and no chasing into walls.
- PIR coverage angle 110° and range 12 m. The microwave section confirms within a 90° coverage angle up to 12 m.
- Dual evaluation in one module. Occupies one system position.
Why choose this product
Dual principle: an alarm only when both agree
When the PIR registers movement, the microwave section is activated and an alarm is only raised when both agree. Halls with temperature fluctuations or areas near heating therefore do not cause an alarm from a thermal change alone.
- Wireless transmission at 868 MHz, range approximately 300 m
- PIR coverage 110° / 12 m, microwave 90° / 12 m
- Occupies one system position
For industrial and glazed environments
The dual principle is suitable for halls, warehouses and areas with temperature fluctuations, where a PIR on its own reports false alarms.
- PIR and microwave immunity adjustable in F-Link
- Microwave sensitivity adjustable in F-Link
- Can be combined in one system with its sibling, the JA-161PW
Versions and immunity to light
The versions with a different lens extend use to areas with strong daylight, where the white version could have lower immunity to false alarms caused by glare.
- White version: immunity to white light up to 6,000 lux
- GR/AN versions: immunity to white light up to 10,000 lux
- Support for the JA-191PL articulated bracket
Frequently asked questions
The detector combines a passive infrared sensor and a microwave sensor. An alarm is only raised on simultaneous detection by both, which reduces the number of false alarms.
In an environment with draughts, heating or direct sunlight, where a PIR on its own reports false alarms caused by thermal effects. The dual principle confirms the movement with a second, independent sensor.
The JA-161PW uses the same dual principle in a more compact design without the GR/AN versions. The JA-162PW additionally offers versions with increased immunity to white light and support for the JA-191PL bracket.
Technical specifications
- Power supply
- 2x lithium battery, type: CR123A (3 V/1500 mAh) Please note: Batteries are not included.
- Typical lifetime of batteries
- 4 Years
- LowBatt state
- < 2,7 V
- Quiescent current consumption
- 65 µA
- Maximum current consumption
- 50 mA
- Communication band
- 868,1 MHz, JABLOTRON protocol
- Maximum radio-frequency power (ERP)
- 25 mW
- Communication range
- cca 300 m (open area)
- Recommended installation height
- 2.2 – 2.5 m above floor level
- Detection angle/detection coverage PIR
- 90°/12 m
- Detection angle/detection coverage MW
- 80°/12 m
- Operational frequency MW
- 24,125 GHz
- Maximum radio-frequency power (ERP)
- 30 mW
- Dimensions
- 63 x 150 x 40 mm
- Weight (w/o batteries)
- 125 g
- Classification
- Security grade 2/Environmental class II (according to EN 50131-1)
- Operating temperature range
- -10 °C to +40 °C
- Average operating humidity
- 75 % RH, w/o condensation
- Certification body
- Trezor Test s.r.o. (no. 3025)
- In compliance with
- ETSI EN 300 220-1,-2, ETSI EN 300 440, EN 50130-4, EN 55032, EN 62368-1, EN 50581, EN 50131-1, EN 50131-2-4, EN 50131-5-3, EN 50131-6
- Operating conditions according to general authorization
- ERC REC 70-03
Warning
It is not possible to mount multiple MW detectors with overlapping fields of view - they interfere with each other. The microwave signal passes through walls - orient the detector in the right direction.
- Do not touch the PIR sensor inside, you could damage it. Do not install two microwave detectors in one room; their transmitters would interfere with each other. Microwaves pass through non-metallic obstacles, so carry out a test after installation. The control unit must contain a JA-11xR radio module, and always replace both batteries together.
Installation example
Mount it no more than 2.5 m above the floor; do not install two or more units in an area where the microwave detectors could interfere with each other.
Open the cover by pressing the latch, do not touch the PIR sensor inside, and take out the electronics.
Screw the rear plastic to the wall and put the electronics back in.
Insert both batteries; stabilisation takes approximately three minutes. Enrol the detector according to the control unit manual; the control unit must have a JA-11xR radio module. Set the PIR and MW immunity and the MW sensitivity in F-Link.
Close the cover and secure it with the locking screw.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-EXT-TH-R
Wireless outdoor thermometer
Help us improve the catalog