JB-150N-HEAD
Wireless thermostatic head
It controls the valve of a hot-water radiator or an underfloor heating manifold according to the PG outputs of the control unit. Simple installation with no building preparation of any kind.
Product line
- JABLOTRON 100+
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- 3 x Alkaline batteries type AA (LR6) 1.5 V Warning: batteries are not included
- Current consumption (nominal/maximum)
- 0.025/550 mA
- Maximum radio-frequency power (ERP)
- 2.5 mW
- Protection rating (IP)
- IP40
- Limit values of the switchgear
- T60
- Typical battery lifetime
- approximately 2 heating seasons (10 cycles/day) (1 heating season of 10 cycles/day - when using a Giacomini valve)
- Communication band
- 868.1 MHz, JABLOTRON protocol
Basic description
The valve head opens and closes the valve according to the selected PG outputs of the control unit, which are controlled by a system thermostat. It is retrofitted to the valve using an adapter, either directly on a radiator or inside an underfloor heating manifold. The package includes a VA 50 adapter with an M30x1.5 thread; for other valve types, the JB-VA16, JB-VA26, JB-VA78 and JB-VA80 adapters are available separately. Even without cabling in place, the valve in each room can therefore be controlled by its own PG output.
- The batteries last the whole heating season and are easy for the user to replace. The valve head reports flat batteries in good time.
- The valve head copies the control unit's PG output controlled by the thermostat.
- Automatic protection against the valve seizing up outside the heating season (if there has been no heating for 14 days, it briefly opens and closes)
- Up to 48 valve heads per system
Why choose this product
Compatibility with different valves
It is installed directly on the valve in place of a conventional manual thermostatic head. First a plastic adapter is screwed on, and then the whole valve head simply clicks onto it. Each time the cover is closed, the valve head automatically calibrates itself to the type of valve; no special settings are needed.
- The package includes a VA 50 adapter for the most commonly used valves with an M30x1.5 thread.
- Additional adapters for less common valve types are available, sold separately in packs of 5: JB-VA16, JB-VA26, JB-VA78 and JB-VA80
Frequently asked questions
You need a source of demand. The room temperature must be monitored by a system thermostat or sensor that controls one of the PG outputs in the control unit; you then assign that output to the valve head, and it opens or closes the valve accordingly. A radiator does not heat by itself, so the heat source must also be switched on.
The valve opens and the radiator remains open to flow; the valve head signals the loss of connection with a lit yellow LED. Once communication is restored, it switches according to the current demand. Whether heating actually takes place in the meantime depends on the heat source, which is switched by a different output.
Technical specifications
- Power
- 3 x Alkaline batteries type AA (LR6) 1.5 V Warning: batteries are not included
- Current consumption (nominal/maximum)
- 0.025/550 mA
- Maximum radio-frequency power (ERP)
- 2.5 mW
- Protection rating (IP)
- IP40
- Limit values of the switchgear
- T60
- Typical battery lifetime
- approximately 2 heating seasons (10 cycles/day) (1 heating season of 10 cycles/day - when using a Giacomini valve)
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Communication range
- approx. 300 m (open area)
- Dimensions
- 85 x 49 mm
- Weight
- 105 g
- Operating temperature range
- 0 °C to + 40 °C RV 75% non-condensing
- Complies with
- ETSI EN 300 220-1, EN 50130-4, EN 55022, EN 60950-1, EN 60730-1 ed.3, EN 607-2-8
- Can be operated according to
- VO-R/10 (ERC REC 70-03)
Warning
- Choose the adapter according to the specific valve: with the wrong one, calibration fails and the valve head cannot control the valve. With Giacomini valves, the battery life is roughly halved. Always replace all the batteries at once and use only new ones of the same type and manufacturer; before removing them, wait until the motor has finished moving and the push piston has retracted into the valve head. Then close the battery cover without delay, otherwise the system reports a fault. When re-enrolling to a different system, the valve head must not be within range of the original control unit. The control unit must have a JA-11xR radio module.
Installation example
Remove the original head from the valve.
Screw a suitable adapter onto the valve.
In the F-Link program, select the required position on the Devices tab and switch on enrolment mode with the Enrol option.
Insert the batteries into the valve head; this sends the enrolment signal. It can also be enrolled by entering the full serial number from the label under the battery.
Click the valve head onto the adapter.
Close the battery cover. The tamper contact goes to rest and calibration to the type of valve takes place.
In the internal settings, select PG output reaction and, if required, Inverse reaction and set the Tamper contact parameter.
Then follow the installation manual of the control unit.
Related products

JB-EXT-TH-R
Wireless outdoor thermometer

JA-151TH
Wireless temperature detector

JB-151TP
Wireless room thermostat

JB-151TP-AN
Wireless room thermostat - anthracite

JB-151TH
Wireless temperature and humidity sensor with thermostat

JB-151TH-AN
Wireless temperature and humidity sensor with thermostat - anthracite

JA-111TH
Bus temperature detector

JB-EXT-TH-B
Bus outdoor thermometer

JB-111TP
Bus room thermostat

JB-111TP-AN
Bus room thermostat - anthracite

JB-111TH
Bus temperature and humidity sensor with thermostat function

JB-111TH-AN
Bus temperature and humidity sensor with thermostat function - anthracite
Help us improve the catalog
Missing something, or found a mistake? Let us know.