JB-111TH
Bus temperature and humidity sensor with thermostat function
It controls heating, cooling and ventilation. It allows remote operation and an overview of the temperature and humidity in MyJABLOTRON. It warns when a critical temperature is reached.
Compatibility
JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Temperature measuring range with external sensor
- -40 to+ 125 C° (± 0,2 °C)
- Operating temperature range
- -20 to +40 C°
- Humidity measuring range
- 0 to 100%
- *Temperature controller class
- I. (according to Regulation (EU) No 813/2013)
- *Contribution of controllers to seasonal
- ȠS = 1% (according to Regulation (EU) No 813/2013) *for both parameters in the control panel configuration
- Power supply
- from the control panel bus 12 V DC (10...15 V)
- Rated current consumption
- 5.2 mA
Basic description
The sensor with a thermostat function serves to regulate heating and cooling according to the temperature of the space. Once the optional floor sensor is connected, it makes sure that the floor does not overheat. It switches the PG output connected to the heating system until the required temperature is reached. A heating schedule, the option of remote operation and blocking the heating when the alarm is switched on all help to reduce heating costs. The sensor also measures humidity and can switch a fan on when it rises.
- A single sensor can control heating, cooling and ventilation
- Blocking the heating when you leave or when a window is opened
- The current temperature and humidity in MyJABLOTRON, including the temperature history in a clear graph
- Control and detailed settings from the application; after the button is pressed, the LED shows whether it is heating or cooling
Why choose this product
Automatic operation and remote operation
For use in a home or an office, you will make use of the Calendar mode, in which the sensor switches between the comfort and the economical temperature by itself according to a schedule. For technical areas that need a constant temperature, the Manual temperature mode with a fixed value is ideal. For holiday properties, the option of switching the sensor on and off remotely works excellently. During the heating season, though, it keeps watch even in the switched-off state so that the temperature does not fall below the set limit. In a bathroom it starts the ventilation after a shower according to the humidity.
- Switching between the operating modes and setting the schedule conveniently from a mobile phone
- Keeping a minimum temperature in the Off mode during the heating season
- Automatic venting of excess humidity
Lower costs thanks to linking the heating with the alarm
When you leave (when the alarm is switched on), the system can block the heating in the room. You do not have to think about anything and you still save. The heating switches on again only when the temperature falls to the value of the Off mode, which the sensor then keeps.
- Blocking the heating while you are away
- Blocking the heating in a particular room with an open window
- Switching the heating off remotely when your holiday goes on longer
An immediate warning at a critical temperature
An alarm or a fault can be set up directly in the system for a selectable critical low or high temperature. The function is excellent wherever the temperature of the space is crucial. The air temperature can be watched and, with the floor sensor, the floor temperature as well.
- PUSH notifications and SMS
- Reporting to the ARC
Frequently asked questions
It is the anthracite version of the same product: you order it under the full code JB-111TH-AN and it differs from the basic version neither in its functions nor in its technical parameters.
Yes, once the optional floor sensor is connected. It then does not let the floor overheat above the set ceiling, but it still controls the normal room temperature according to the air.
Technical specifications
- Temperature measuring range with external sensor
- -40 to+ 125 C° (± 0,2 °C)
- Operating temperature range
- -20 to +40 C°
- Humidity measuring range
- 0 to 100%
- *Temperature controller class
- I. (according to Regulation (EU) No 813/2013)
- *Contribution of controllers to seasonal
- ȠS = 1% (according to Regulation (EU) No 813/2013) *for both parameters in the control panel configuration
- Power supply
- from the control panel bus 12 V DC (10...15 V)
- Rated current consumption
- 5.2 mA
- Maximum current draw
- 22 mA
- IP resistance
- IP 31
- Dimensions
- 82 x 82 x 22 mm
- Weight
- 82.9 g
- Operating humidity
- 75 % (non-condensing)
- Environment
- indoor general
- Further complies with
- EN 50130-4, EN 55032, EN IEC 63000
- Recommended screws
- 2x ø 3,5 mm (hemispherical head)
Warning
- If several thermostats heat from one central heat source, we recommend switching the source with a common PG output using OR logic, which copies the demands of the individual thermostats. If the measurement is affected by air flow, compensate for the deviation with the temperature correction in the settings. The sensor does not detect tampering, so in alarm systems with security grade 2, connect it behind the JA-110T bus isolator. For the full range of functions, the system must be registered in the JABLOTRON Cloud; some functions may be charged for.
Installation example
Always connect the bus with the system power supply completely switched off.
For surface mounting, break the plastic square out of the rear part so that the cables can be pulled through, pull the cables through the square hole and fix the rear part to the wall with two screws.
For partially recessed mounting, pull the cables through the hole in rear part B and fix it into the KU wiring box with two screws.
Connect the bus wires, and the floor sensor wires if applicable, to the terminal block.
Fit the top part into the latches and secure it by pulling it down.
Secure the product by turning the locking mechanism clockwise.
Then follow the installation manual of the control unit: in the F-Link program, select the required position on the Devices tab and switch on enrolment mode with the Enrol button.
Open the Scan/add new BUS devices selection and double-click to select the thermostat; it can also be enrolled by entering the full serial number. Then continue to the Internal settings of the thermostat.
Related products

JA-111TH
Bus temperature detector

JB-EXT-TH-B
Bus outdoor thermometer

JB-111TP
Bus room thermostat

JB-111TP-AN
Bus room thermostat - anthracite

JB-111TH-AN
Bus temperature and humidity sensor with thermostat function - anthracite

JB-150N-HEAD
Wireless thermostatic head

JB-EXT-TH-R
Wireless outdoor thermometer

JA-151TH
Wireless temperature detector

JB-151TP
Wireless room thermostat

JB-151TP-AN
Wireless room thermostat - anthracite

JB-112TH
BUS temperature, humidity and CO₂ sensor with thermostat function

JB-112TH-AN
BUS temperature, humidity and CO₂ sensor with thermostat function - anthracite
Help us improve the catalog
Missing something, or found a mistake? Let us know.