JB-151TP
Wireless room thermostat
It controls heating, cooling and ventilation. It allows remote operation and an overview of the temperature and humidity in MyJABLOTRON. It warns when a critical temperature is reached.
Product line
- JABLOTRON 100+
Compatibility
JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Temperature measuring range with external sensor
- -40 to+ 125 C° (± 0.2° C)
- Operating temperature range
- -20 to +40 C°
- Humidity measuring range
- 0 - 100 %
- *Temperature controller class
- I. (according to Regulation (EU) No 813/2013)
- *Contribution of controllers to seasonal
- ȠS = 1 % (according to Regulation (EU) No 813/2013) *for both parameters in the control panel configuration
- Power supply
- 2x alkaline 1.5 V AA type LR6 (BAT-1V5-AA recommended) | Batteries are not included.
- Typical battery life
- 2.5 years / 3.5 years (active / inactive button lock)
Basic description
The thermostat serves to regulate heating and cooling according to the temperature of the space. Once the optional floor sensor is connected, it makes sure that the floor does not overheat. It switches the PG output connected to the heating system until the required temperature is reached. A heating schedule, the option of remote operation and blocking the heating when the alarm is switched on all help to reduce heating costs. The thermostat also measures humidity and can switch a fan on when it rises.
- A single thermostat can control heating, cooling and ventilation
- Blocking the heating when you leave or when a window is opened
- The current temperature and humidity in MyJABLOTRON, including the temperature history in a clear graph
- Simple control with buttons and a child lock, with detailed settings and control from the application
Why choose this product
Automatic operation and remote operation
For use in a home or an office, you will make use of the Calendar mode, in which the thermostat switches between the comfort and the economical temperature by itself according to a schedule. For technical areas that need a constant temperature, the Manual temperature mode with a fixed value is ideal. For holiday properties, the option of switching the thermostat on and off remotely works excellently. During the heating season, though, it keeps watch even in the switched-off state so that the temperature does not fall below the set limit. In a bathroom it starts the ventilation after a shower according to the humidity.
- Switching between the operating modes and setting the schedule conveniently from a mobile phone
- Keeping a minimum temperature in the Off mode during the heating season
- Automatic venting of excess humidity
Lower costs thanks to linking the heating with the alarm
When you leave (when the alarm is switched on), the system can block the heating in the room. You do not have to think about anything and you still save. The heating switches on again only when the temperature falls to the value of the Off mode, which the thermostat then keeps.
- Blocking the heating while you are away
- Blocking the heating in a particular room with an open window
- Switching the heating off remotely when your holiday goes on longer
An immediate warning at a critical temperature
An alarm or a fault can be set up directly in the system for a selectable critical low or high temperature. The function is excellent wherever the temperature of the space is crucial. The air temperature can be watched and, with the floor sensor, the floor temperature as well.
- PUSH notifications and SMS
- Reporting to the ARC
Frequently asked questions
It is the anthracite version of the same product: you order it under the full code JB-151TP-AN and it differs from the basic version neither in its functions nor in its technical parameters.
Yes, once the optional floor sensor is connected. The thermostat then does not let the floor overheat above the set ceiling, but it still controls the normal room temperature according to the air.
Technical specifications
- Temperature measuring range with external sensor
- -40 to+ 125 C° (± 0.2° C)
- Operating temperature range
- -20 to +40 C°
- Humidity measuring range
- 0 - 100 %
- *Temperature controller class
- I. (according to Regulation (EU) No 813/2013)
- *Contribution of controllers to seasonal
- ȠS = 1 % (according to Regulation (EU) No 813/2013) *for both parameters in the control panel configuration
- Power supply
- 2x alkaline 1.5 V AA type LR6 (BAT-1V5-AA recommended) | Batteries are not included.
- Typical battery life
- 2.5 years / 3.5 years (active / inactive button lock)
- Low battery voltage detection
- 2.2 V
- Rated current draw
- 110 µA
- Maximum current draw
- 100 mA
- IP resistance
- IP 31
- Communication frequency
- 868.1 MHz Jablotron protocol
- Communication range
- 500 m
- Max. radio frequency power ERP
- <25 mW
- Dimensions
- 82 x 82 x 22 mm
- Weight (without batteries)
- 99.7 g
- Operating humidity
- 75 % (non-condensation)
- Environment
- indoor general
- It also meets
- EN 60730-1, EN IEC 62368-1, EN 50130-4, EN 55032, ETSI EN 300 220-2, EN IEC 63000
- Recommended screws
- 2x ø 3.5 mm (half-round head)
Warning
- Do not let the temperature for the Off mode fall below 12 °C. At lower values, mould and other unwanted phenomena may occur in a normal interior. The control unit must have a JA-11xR radio module. For the full range of functions, the system must be registered in the JABLOTRON Cloud; some functions may be charged for.
Installation example
Turn the locking mechanism anticlockwise and open the product.
Break the side terminal block holders out of the rear part to make room for the batteries.
If you are connecting an external sensor, connect its wires to the terminal block on the rear plastic part.
Fix the rear part to the wall with two screws.
Insert the batteries into the back of the top part, fit the top part into the latches and secure the product by moving it down.
Secure it by turning the locking mechanism clockwise and mind the correct polarity of the batteries.
Then follow the installation manual of the control unit: in the F-Link program, select the required position on the Devices tab and switch on enrolment mode with the Enrol button.
Enter the full serial number, or start the enrolment by inserting the batteries; as soon as the thermostat appears in the list of peripherals, set its properties on the Internal settings tab.
Related products

JA-152P
Wireless PIR motion detector

JA-159P
Wireless outdoor PIR detector

JA-161PW
Wireless PIR and MW combined detector

JA-162PW
Wireless dual PIR and MW motion detector

JA-162PC
Wireless PIR motion detector with a 90° verification camera

JA-153M
Wireless magnetic detector with recognition of external magnetic fields

JA-150M
Wireless magnetic detector with 2 universal inputs

JA-155M
Wireless mini magnetic detector

JA-180PB
Wireless PIR and glass-break combined detector

JA-150ST
Wireless fire and temperature detector

JA-151ST
Wireless combined smoke and heat detector with built-in siren

JB-150N-HEAD
Wireless thermostatic head
Help us improve the catalog
Missing something, or found a mistake? Let us know.