JA-111I

Universal LED indicator RGB

Optical indicator with four separate inputs, each of which lights a different colour. A colour lights up when something switches its input to GND, so the colour is determined by the way it is wired. The installation must therefore have an output, relay or contact ready for each colour used.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K

Check compatibility

Key specifications

Power
12 V (9 … 15 V)
Standby power consumption (LED on/off)
5 mA/0 mA
Current consumption for cable selection
5 mA
Dimensions
62 x 36 x 27 mm
Operational environment according to
EN 50131-1 II. Indoor general
Operating temperature range
-10 °C to 40 °C

Basic description

The two indicators differ in where they take their status information from, and that is decisive when choosing. The JA-112I reads it directly from the bus: configuration switches assign it a section or a programmable output, which it then displays by itself. The JA-111I is controlled exclusively by what you bring to its terminals; each of the four colours lights up when the corresponding input is switched to GND, so an output, relay or contact must be ready in the installation for each colour. Therefore choose the JA-111I where you need several colours and already have the switching signals available, and the JA-112I where the light is to show the status of a single section or programmable output.

  • Four colours from one device. Red, green, blue or yellow is lit by whichever input is currently switched to GND.
  • Power supply 12 V, range 9 to 15 V, consumption 5 mA with the LED lit. It is connected via the terminals +U, R, G, B and Y.
  • Inside or outside the protected area. If the indicator is outside the protected area and the voltage for +U is tapped from the system bus, protect the +U supply against short circuit, for example with a JA-110T isolator.

Why choose this product

Colour indication

The indicator displays exactly what the installation brings to its four inputs. The signal source for each colour, whether a programmable output, a relay or a simple contact, is therefore part of the installation design just like the indicator itself. Two-colour use is common, with one colour showing the closed state of the controlled output and the other the open state.

  • Four separate inputs: red, green, blue, yellow
  • An input lights the LED when switched to GND
  • The colour is determined by the choice of input when wiring

Power supply and connection

Electrically, it is a very simple device: a voltage supply and four control wires. Current flows only to the colour that is currently to be lit; in the idle state, consumption is zero. The control wires are switched against the system ground, so they can be driven by any programmable output, relay or simple contact.

  • Power supply 12 V, range 9 to 15 V
  • Consumption 5 mA with the LED lit, 0 mA when off
  • Terminals +U, R, G, B and Y

Where to place it

The indicator may be placed inside or outside the protected area; both locations are permissible and differ only in how the power supply line must be treated. The installation environment is indoor, so the indicator belongs inside, not on a façade. Installation and wiring are a job for a trained technician.

  • Indoor – general environment, class II, temperatures −10 to +40 °C
  • Outside the protected area, protect +U tapped from the bus against short circuit, for example with a JA-110T isolator
  • Dimensions 62 × 36 × 27 mm