JA-150A II
Wireless internal siren
DiscontinuedIndoor wireless siren with a piezoelectric transducer and an acoustic pressure of 100 dB/1 m (±5 dB). In addition to alarms, it also sounds programmable outputs, entry and exit delays or a doorbell. It is powered by a fixed 110 to 230 V AC mains supply and, with a BAT-3V2-CR2 battery inserted, it is classified as a type Y warning device with 24 h backup.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power supply/wattage
- 110 - 230 V/50 - 60 Hz, 0.6 W, protection class II
- Connecting cables - maximum diameter
- 1.5 mm 2
- Backup/recharge time
- min. 24 h/max 72 h
- Battery type
- BAT-3V2-CR2/LiFePo4 Warning: Battery is not installed
- Battery/lifetime
- 3.2 V; 470 mAh/3 years
- Battery/minimum voltage when loaded
- 3.0 V
- Battery/maximum voltage when unloaded
- 3.6 V
Basic description
The JA-150A II is an indoor siren with a fixed 110 to 230 V AC mains supply. It mounts on the wall surface or on an electrical installation box, so you can place it even where there is no socket; however, the supply must be connected by a person with an electrical qualification. Where the installation is to be done without drilling and without this qualification, the family includes the plug-in JA-152A, and for places with neither a supply nor a socket the battery-powered JA-154A. The JA-150A II shares the acoustic pressure of 100 dB/1 m and the classification as a type Y warning device with 24 h backup with the JA-152A.
- Audible alarm signalling inside the building. Press the button to silence the alarm, and the system records that someone is present.
- Fixed 110 to 230 V AC mains supply for places without a socket. It must be connected by a person with an electrical qualification, because the electronics are galvanically connected to the mains.
- Acoustic pressure 100 dB/1 m (±5 dB). Indoor – general environment, −10 to +40 °C.
- Occupies one position in the system and requires a JA-11xR radio module in the control unit. Update the firmware wirelessly from F-Link.
Why choose this product
Sound for alarms and everyday operation
The siren sounds in the sections you assign to it and, by default, responds to the internal warning signal IW; it can be switched to the external warning EW. Alarm sounding can be disabled without the siren losing its other indications. It can distinguish a fire alarm by fast beeping, matching the smoke detectors. The volume of the supplementary acoustic indication is set separately, and the higher priority always takes precedence, i.e. fire over alarm and alarm over ordinary indication.
- Piezoelectric transducer, acoustic pressure 100 dB/1 m (±5 dB)
- Siren time 1 to 5 minutes or according to the alarm length from the control unit
- Sounding of programmable outputs and four doorbell melodies
Fixed supply with battery backup
The siren is powered by a fixed mains supply in protection class II; the cable is fed through a knock-out opening in the base and connected to the terminals on the electronics. Because the electronics are galvanically connected to the mains, the supply may only be connected by a person with the relevant electrical qualification. Order the back-up battery separately and insert it during installation; once it is connected, the siren detects it automatically, diagnoses it continuously and reports approaching discharge to the user and the service. During a power failure, it keeps running from the inserted battery, and only with it does it meet the classification of a type Y warning device.
- Fixed 110 to 230 V AC mains supply, rated consumption 0.6 W, maximum 2.5 W
- BAT-3V2-CR2 rechargeable battery (3.2 V, 400 mAh), backup of at least 24 h, recharging within 72 h
- Indoor – general environment, −10 to +40 °C, humidity 75% RH
Enrolment, tamper and settings
The siren is an addressable peripheral that you enrol in F-Link on the Devices tab using Enrol and by pressing the button, or by entering the serial number from the label. In Internal settings, you then define the sections, reaction, siren time, volume of the supplementary acoustic indication and the sounding of programmable outputs. For a certified installation, apply the settings in one step with the EN 50131 system profile. The firmware is updated wirelessly directly from F-Link, and after the update it is advisable to check the internal settings and test the operation of the siren.
- Occupies one position in the system, range approximately 300 m in line of sight
- Requires a JA-11xR radio module in the control unit
- Front protective contact and rear contact against being pulled off the wall
Frequently asked questions
A person with the relevant electrical qualification, because the siren electronics are galvanically connected to the mains. The 110 to 230 V AC supply is fed through a knock-out opening in the base and connected to the terminals; the maximum conductor cross-section is 1.5 mm². The siren is then enrolled and configured by a trained technician holding a valid JABLOTRON certificate.
Order the BAT-3V2-CR2 battery (3.2 V, 400 mAh) separately and insert it into the siren during installation; do not use any other type. Once it is connected, the siren detects it, runs a diagnostic and reports low voltage at 2.6 V. Only with the battery inserted does it meet the classification of a type Y warning device with 24 h backup. The typical back-up battery lifetime is 3 years.
Programmable outputs, by slow or fast beeping, when switched on and off, by a twenty-second beep or by one of four doorbell melodies. It also sounds section control, alert indication, entry and exit delays and alarm memory. The supplementary acoustic indication has four volume modes, including a programmable time interval, and can be accompanied by the LED lighting up. The siren can distinguish a fire alarm by fast beeping, matching the smoke detectors.
Technical specifications
- Power supply/wattage
- 110 - 230 V/50 - 60 Hz, 0.6 W, protection class II
- Connecting cables - maximum diameter
- 1.5 mm 2
- Backup/recharge time
- min. 24 h/max 72 h
- Battery type
- BAT-3V2-CR2/LiFePo4 Warning: Battery is not installed
- Battery/lifetime
- 3.2 V; 470 mAh/3 years
- Battery/minimum voltage when loaded
- 3.0 V
- Battery/maximum voltage when unloaded
- 3.6 V
- Communication band
- 868.1 MHz, JABLOTRON protocol
- Communication range
- approx. 300 m (open area)
- Classification
- security grade 2/environmental class II
- - According to
- EN 50131-1
- - Alarm sound level
- 100 dB/1 m (±5 dB/1 m)
- - Back up power supply
- type W/24h back up
- - Operational environment
- indoor general
- - Operating temperature range
- -10 °C to +40 °C
- - Average operational humidity
- 75 % RH, non-condensing
- - Certification body
- Trezor Test s.r.o. (no. 3025)
- IP rating
- IP43 according to EN 50131-1
- Dimensions
- 80 x 80 x 35 mm
- Also complies with
- ETSI EN 300 220, EN 50130-4+A1:2014, EN 55032:2015, EN 62368-1, EN 50131-5-3, EN 50581:2012, EN 50131-4, EN 50131-6
- Can be operated according to
- ERC REC 70-03
Warning
- The mains supply may only be connected by a person with the relevant electrical qualification, because the electronics are galvanically connected to the mains. The siren is intended for an indoor – general environment, i.e. environmental class II, −10 to +40 °C and humidity 75% RH, non-condensing. It provides visual indication with a yellow LED and its main output is sound; outdoor visual signalling of an alarm is provided by the JA-163A outdoor siren. Order the BAT-3V2-CR2 battery (3.2 V, 400 mAh) separately and insert it during installation; do not use any other type. When dimensioning the power supply circuit, work from the maximum consumption of 2.5 W, not from the rated 0.6 W. The battery is replaced by a technician in service mode, within two weeks of the approaching discharge being reported. When inserting the button panel, the tamper sensors must lie above the magnets in the base, otherwise tamper protection does not work. The volume of the supplementary acoustic indication is set separately; an alarm always sounds at 100 dB/1 m. The Off option for limiting the siren time means that the alarm length set in the control unit is respected, not silence. After a firmware update, the previous settings may be retained or reset to the default values, so check the internal settings and test the operation of the siren. In the firmware update table, the siren is shown as JA-150A without the Roman numeral two. The classification is Security Grade 2 and a type Y warning device with 24 h backup; you can apply it in one step with the EN 50131 profile, Grade 2. Installation may only be carried out by a trained technician holding a valid JABLOTRON certificate.
Installation example
The mains supply may only be installed by a person with the relevant electrical qualification; the electronics are galvanically connected to the mains.
Prise the siren button panel out of the plastic frame with a flat screwdriver in the vertical slot.
Remove the middle part of the frame by pressing the four latches.
Break out the knock-out opening in the base and pass the power cable through it.
Screw the base to the wall surface or onto an electrical installation box with 2× Ø 3.5 × 40 mm countersunk head screws and place the BAT-3V2-CR2 battery against the top wall.
Connect the power cable to the terminals and plug the battery into the electronics in the base; the maximum conductor cross-section is 1.5 mm².
Fit the middle frame back onto the base; this secures the battery in place.
Connect the button panel connector and insert the button panel back into the frame so that the tamper sensors lie above the magnets in the base.
In F-Link, select a position on the Devices tab, start enrolment mode using Enrol and press the siren button panel; the yellow LED goes off.
Alternatively, enrol the siren by entering the full serial number in F-Link.
In Internal settings, set the sections, reaction, siren time, volume and signalling of programmable outputs.
For a certified installation, use System profiles, EN 50131, Grade 2 in F-Link.
Related products

JA-163A
Wireless outdoor battery powered siren

JA-154A
Wireless battery indoor siren

JA-152A
Wireless internal siren for an AC socket

JA-1X2A-C-WH
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - white, transparent light guide

JA-1X2A-C-AN
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - anthracite, transparent light guide

JA-1X2A-C-GR
Plastic cover for JA-113A, JA-111A, JA-151A and JA-163A - grey, transparent light guide

JA-110A
Bus internal siren

JA-110A II
Bus internal siren with battery back-up

JA-111A
Bus external siren

JA-113A
Bus external siren

OS-350
Siren

OS-365A
Outdoor siren
Help us improve the catalog