JA-192Y
GSM communicator module
DiscontinuedGSM communicator module installed in the control unit, communicating over the GSM and GPRS mobile network. It reports alarms to the Alarm Receiving Centre, allows control from the application and remote configuration in the F-Link software, and delivers alarm SMS and voice messages.
Product line
- JABLOTRON 100+
Compatibility
JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Module power supply
- 12 V DC (from the control panel)
- Average current consumption
- approx. 5 mA (depends on the GSM signal strength)
- Peak current consumption
- 175 mA
- GSM communication band
- QUAD-BAND, 850/900/1800/1900 MHz
- I&HAS classification
- Security grade 2/Environmental class II (Note: this applies only in combination with a security-grade-2-certified control panel. For more info about ARC settings, see the Control panel installation manual)
- - Conforms to
- EN 50131-1 +A1 ¬+A2, EN 50131-3, EN 50131-10, EN 50136-1, EN 50136-2, ANSI SIA DC-09
- - Certification body
- Trezor Test s.r.o.
Basic description
With this trio, the deciding factors are the generation of mobile network the communicator is to use and the range of services. The JA-192Y connects to the GSM network, the JA-194Y and JA-194Y-LITE to the LTE network. The JA-192Y and JA-194Y also deliver alarm SMS and voice messages.
- Provides the connection between the control unit and the Alarm Receiving Centre and allows control from the application and remote configuration in the F-Link software.
- Powered from the control unit and connects to the mobile network via a SIM card.
- Connects to the GSM and GPRS network.
- Complies with security grade 2 and environmental class II according to EN 50131-1; this applies only in combination with a control unit certified for security grade 2.
Why choose this product
What the module provides and how it is configured
The control unit reports alarms using a digital protocol over the mobile network; the communicator works as an expansion module of the control unit and is configured in the F-Link software.
- It transmits messages using the JABLO SMS protocol and data using the JABLO IP or ANSI SIA DC-09 protocol over the mobile network; it supports the DP4 dual path only together with the control unit's LAN communicator.
- Delivers alarm SMS messages and voice messages.
- In border areas, a fluctuating signal can cause roaming and a significant increase in communication costs; this is solved by having the operator block roaming on the SIM card.
What the control unit needs
Plugs directly into the dedicated connector on the control unit board and is configured in the F-Link software; during configuration, the control unit should be in Service mode.
- The compatibility overview on the website confirms which control units the module works with.
- Requires an activated nano SIM card with the PIN request disabled; a contract SIM card is recommended.
- The average current draw from the control unit is approximately 5 mA depending on signal strength, with a peak of 175 mA.
Where it is installed
It is inserted at an angle into the connector on the control unit board and secured with two locking screws.
- The antenna is supplied, screws into the SMA connector and must be connected before you put the module into operation.
- Powered from the control unit at 12 V DC.
- Network registration takes approximately 1 minute and is confirmed when the red GSM LED on the control unit board goes out. The green LED on the communicator flashes when it is working correctly.
Frequently asked questions
It depends on how long the GSM network will be available from your operator in your area.
In addition to the connection with the Alarm Receiving Centre, it also delivers alarm SMS and voice messages.
Technical specifications
- Module power supply
- 12 V DC (from the control panel)
- Average current consumption
- approx. 5 mA (depends on the GSM signal strength)
- Peak current consumption
- 175 mA
- GSM communication band
- QUAD-BAND, 850/900/1800/1900 MHz
- I&HAS classification
- Security grade 2/Environmental class II (Note: this applies only in combination with a security-grade-2-certified control panel. For more info about ARC settings, see the Control panel installation manual)
- - Conforms to
- EN 50131-1 +A1 ¬+A2, EN 50131-3, EN 50131-10, EN 50136-1, EN 50136-2, ANSI SIA DC-09
- - Certification body
- Trezor Test s.r.o.
- - Dimensions
- 70 x 37 x 25 mm
- - Weight
- 25 g
- - Operational environment
- indoor general
- - Operational temperature
- -10 °C to 40 °C
- - Average operational humidity
- 75% RH, non-condensing
- - Compatible with RCT (ARC receiver)
- According to communication protocols
- - SPT communicator type
- SPT type Z (control panel expansion module)
- - AS/SPT interface
- Pass-through
- Also complies with
- EN 62368-1, ETSI EN 301 511, EN 50130-4 +A1, ETSI EN 301 489-1, ETSI EN 301 489-7, EN 55032, ETSI EN 301 419-1, EN 50581
- Caller ID (CLIP)
- ETSI EN 300 089
- Can be operated according to
- CEPT/ECC/DEC/(04)06
Warning
- If you want to establish a dual path, this communicator and a Wi-Fi WAN network cannot be used at the same time; both count as a radio path.
Installation example
Prepare an activated nano SIM card with SMS, data, voice and caller ID services and disable the PIN request.
Disconnect the control unit from its power supply: both the rechargeable battery and the mains.
Insert the SIM card into the holder in the communicator.
Insert the communicator at an angle into the connector on the control unit board and secure it with two locking screws.
Screw the GSM antenna into the SMA connector in the marked orientation.
Switch on the power, first the battery, then the mains, and wait for network registration.
Close the control unit cover.
In Service mode, set the communicator properties in the F-Link software.
Related products

JA-103K
Control panel JA-103K

JA-107K
Control panel JA-107K

JA-108K
Control panel JA-108K

JA-111R
Bus interface for JA-100 wireless devices

JA-103KR
Control panel JA-103KR

JA-103K-7AH
Control panel JA-103K-7AH

JA-107KR
Control panel JA-107KR

JA-194Y
LTE communicator module

JA-194Y-LITE
LTE communicator module

JA-121T
RS-485 bus interface

JA-112R
Bus module for connecting JA-100 wireless components

JA-190X
Telephone communicator module
Help us improve the catalog
Missing something, or found a mistake? Let us know.