AC-160-C

Mounting-box-fitted wireless multifunctional power relay

Wireless multifunction relay of the JABLOTRON system with a switching output contact, controlled by the control unit via a command to the assigned programmable output. Without a control unit, it can also switch on its own, according to detectors and remote controls enrolled directly to it.

Product line

  • JABLOTRON 100+

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K

Check compatibility

Key specifications

Operational power
100 - 230 V/50 - 60 Hz
Own power consumption for 230 V AC (min/max)
0.2 W/0.7 W
Communication band
868.1 MHz, Jablotron protocol
Antenna
Internal
- Maximum switching voltage
250 V AC
- Resistive load (cos φ=1)
max.16 A
- Inductive, capacitive load (cos φ=0,4)
max. 8 A

Basic description

The choice between the two multifunction relays depends on the mounting location: the AC-160-C fits inside a plastic electrical junction box, the AC-160-DIN belongs on a DIN rail in a distribution board. Both are enrolled to the system as wireless peripherals and controlled by the control unit. Where equipment needs to be switched only according to a voltage signal, without a link to the control unit, the RB-524-DIN steps in instead.

  • Wireless multifunction relay that the control unit controls remotely. In stand-alone mode, it switches even without a control unit, according to detectors and remote controls enrolled directly to it.
  • It communicates using the JABLOTRON wireless protocol and has a built-in antenna. It takes power from the mains and, once enrolled to the system, needs no further cabling to the control unit.

Why choose this product

What the relay switches and how

The relay switches according to a command from the control unit to the assigned programmable output. Without a control unit, it works independently in stand-alone mode, in which it is triggered by detectors or remote controls enrolled directly to it.

  • Stand-alone mode: detectors and remote controls are enrolled directly to the relay, up to 64 devices in total. It accepts one-way JA-15x series detectors and JA-15xJ MS or JA-16xJ remote controls; it does not support JA-18x series detectors.
  • The common timer for the switching time can be set from 1 second to 23:59:59; preset values of 3 seconds, 1 minute, 3 minutes, 15 minutes and 30 minutes are also available.
  • The relay returns to the idle state if a communication failure with the control unit lasts longer than 1 minute; for an enrolled detector, the interval for returning to idle is 20 minutes. After communication is restored, the state stabilises within 2 minutes at the latest, or within 9 minutes for detectors with periodic transmission.

What the system needs for it

The relay is a peripheral like any other: in the F-Link software, on the Devices tab, you select the position to which the relay is enrolled and configure its behaviour there.

  • The control unit must be fitted with a JA-11xR radio module.
  • It occupies one position in the control unit.
  • It communicates at 868.1 MHz; operating conditions are governed by the general authorisation of the Czech Telecommunication Office (ČTÚ).

Where it is mounted and what it switches

The relay is installed in a plastic electrical junction box, where it fits thanks to its small dimensions, and is wired via its switching output contact.

  • It switches voltages up to 250 V AC, resistive loads up to 16 A, capacitive loads up to 8 A, inductive loads up to 6 A and halogen lighting up to 1000 W. The minimum switched DC power is 0.5 W. This is functional single-pole switching that does not provide safe disconnection.
  • Temperature −10 °C to +40 °C, humidity up to 75% RH, non-condensing, IP20 ingress protection.
  • Own power consumption at 230 V AC 0.2 to 0.7 W.