JA-150N
Wireless power output module PG
A universal power relay for a mounting box. An open NO / NC contact for switching up to 16 A of resistive load.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power supply; power consumption
- 230 V/50 Hz; 1.5W
- Communication band
- 868.1 MHz
- - Maximum acceptable relay voltage
- 250 V AC
- - Resistive load (cos φ=1)
- max. 16 A
- - Inductive (capacitive) load (cos φ=0.4)
- max. 8 A
- - Halogen lighting
- max. 1000 W
- - Minimum acceptable relay throughput DC
- 0.5 W
Basic description
The module copies the selected PG output from the control unit. Directly from the mounting box, it switches the power or the control of appliances such as lighting, a fan and the like.
- The option of assigning one PG output to several modules, whose outputs then copy it simultaneously
- Switching according to the setting of the selected section or an alarm in it as well
- Clear LED indication of the status
- Powered directly from the mains, needs no separate power supply
Why choose this product
Load capacity for particular appliances
The power contact withstands AC voltages up to 230 V and DC voltages up to 24 V. The highest switched current differs according to the type of load.
- Purely resistive load up to 16 A, halogen lighting up to an output of 1000 W
- Inductive and capacitive loads (fans, for example) up to 8 A
- A switched DC power of at least 0.5 W
Frequently asked questions
The JA-150N is the power version: it is powered directly from the mains and its contact can carry lighting, a fan or another mains appliance. The JA-151N is the signal version for a low DC supply, for an electric door lock, blocking and indication.
To the status of a selected PG output, to the setting of a section, or to an alarm in a section. You select the mode with the configuration switches on the board and set the PG outputs in F-Link on the PG outputs tab.
It cannot. This is functional single-pole switching that does not provide safe disconnection. For disconnection from the mains, always use the prescribed disconnection device.
Technical specifications
- Power supply; power consumption
- 230 V/50 Hz; 1.5W
- Communication band
- 868.1 MHz
- - Maximum acceptable relay voltage
- 250 V AC
- - Resistive load (cos φ=1)
- max. 16 A
- - Inductive (capacitive) load (cos φ=0.4)
- max. 8 A
- - Halogen lighting
- max. 1000 W
- - Minimum acceptable relay throughput DC
- 0.5 W
- Wire diameter
- max. 2 x 1.5 mm 2 ; max. 1 x 2.5 mm 2
- Dimensions
- 82 x 50 x 19 mm
- Operational environment to EN 50131-1
- Indoor general
- Operating temperature range
- -10 °C to + 40 °C
- Also complies with
- ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
Warning
- The module serves for functional single-pole switching and does not provide safe disconnection, so do not use it as a safety disconnection device. Mains devices may only be connected by a qualified person. The module cannot be installed without a mounting box. Without a JA-11xR radio module in the control unit, the module does not work. Only one control unit can be enrolled to the module, so you cannot share it between two systems. Several modules with the same switch settings switch simultaneously; individual addressing is not possible. During a longer failure of the mains power or of communication with the control unit, the relay goes to the standby state. Operation is limited to the indoor – general environment.
Installation example
Mains devices may only be connected by a qualified person. The module does not provide safe disconnection from the mains.
Place the module in a JA-190PL mounting box.
Use the configuration switches to set the number of the output or section that the relay is to react to, following the setting tables in the manual.
Connect the power cable to the mains power terminal block and switch the power on.
After it is first connected, the yellow LED lights permanently. Press the Enrolment button briefly to make it flash and open enrolment mode, then press Send enrolment signal in F-Link.
Test the function of the module; the switching of the relay contacts is indicated by the red LED.
Only at the very end, connect the switched device to the relay terminal block.
Related products

JA-151N
Wireless signal output module PG

AC-160-C
Mounting-box-fitted wireless multifunctional power relay

JB-160N-PLUG
Smart Wireless Plug (French)

JB-164N-PLUG
Smart Socket with Consumption Measurement (French)

JB-162N-PLUG
Wireless plug with external output (French)

AC-160-DIN
Wireless multifunctional relay for DIN-rail installation

JB-161N-PLUG
Smart Wireless Plug (Schuko)

JB-163N-PLUG
Wireless plug with external output (Schuko)

JB-165N-PLUG
Smart Socket with Consumption Measurement (Schuko)

JB-110N
Bus PG power output module

JA-110N-DIN
Bus DIN power output module

JB-111N
Bus signal PG output module
Help us improve the catalog