JA-110N-DIN
Bus DIN power output module
A universal power relay for a DIN rail. An open NO / NC contact for switching loads of up to 16 A.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Power
- from control panel BUS 12 V (9 … 15 V)
- Current consumption in standby mode (relay off/on)
- 5 mA/45 mA
- Current consumption for cable selection
- 45 mA
- Relay contact capacity (galvanically and securely separated from the BUS)
- Class protection II
- - Maximum switched voltage
- 250 V AC/24 V DC
- - Resistive load (cos φ=1)
- max. 16 A
- - Inductive (capacitive) load (cos φ=0,4)
- max. 8 A
Basic description
The module copies the programmable outputs assigned from the control unit. Directly from the distribution board, it switches the power supply or the control of appliances such as lighting, electric heating, a pump and similar.
- Several programmable outputs can be assigned; the output copies them with OR logic
- Control by a button directly on the module, for testing or emergency operation
- Clear LED indication of the status
- Powered directly from the bus; it needs no separate power supply
Why choose this product
Load capacity for particular appliances
The contact handles an alternating voltage of up to 250 V and a direct voltage of up to 24 V. The maximum current load is determined by the character of the load.
- Purely resistive load (heating, water heater and so on) up to 16 A, halogen lighting with a power of 1,000 W at most
- Inductive and capacitive load (pumps, switched-mode power supplies, conventional fluorescent lights) up to 6 A
- DC maximum switched power 384 W, minimum 0.5 W
Frequently asked questions
In the version and the addressing. JA-110N-DIN belongs on a DIN rail, is enrolled into the system and takes up one position; JB-110N is mounted in a JA-19xPL box and does not take up a position. JA-110N-DIN can also be controlled manually by a button, but it has a lower permitted current for inductive and capacitive loads.
After a short delay, the relay returns to its idle state. Manual control by the button works even without communication with the control unit, so the appliance can be switched on locally.
The character of the load. A resistive load may go up to the full contact current, an inductive and capacitive one only up to a lower limit, so for motors and contactors work from the lower figure. Halogen lighting and direct-current loads are specified separately.
Technical specifications
- Power
- from control panel BUS 12 V (9 … 15 V)
- Current consumption in standby mode (relay off/on)
- 5 mA/45 mA
- Current consumption for cable selection
- 45 mA
- Relay contact capacity (galvanically and securely separated from the BUS)
- Class protection II
- - Maximum switched voltage
- 250 V AC/24 V DC
- - Resistive load (cos φ=1)
- max. 16 A
- - Inductive (capacitive) load (cos φ=0,4)
- max. 8 A
- - Halogen lighting
- max. 1000 W
- - Direct current DC
- 384 W
- - Minimum DC switched output
- 0.5 W
- Connected wires diameter
- max. 2 x 1.5 mm 2 max. 1 x 2.5 mm 2
- Dimensions
- 18 x 90 x 64 mm
- Operational environment
- Indoor general
- Operational temperature range
- -10 °C to + 40 °C
- Protection degree
- IP-20
- Complies with
- EN 50130-4, EN 55022, EN 60950-1
- DIN rail
- EN60715
Warning
- Always connect the bus with the system power supply completely switched off, and leave the connection of mains devices to a qualified person. For inductive and capacitive loads, a markedly lower permitted current applies than for a resistive load; size the protection accordingly as well. After a longer communication failure on the A-B bus, the relay returns to its idle state; allow for this in applications where opening the contact would cause an undesirable state. The module takes up one position, so it has to fit within the system capacity. Include the 1.6 W power dissipation in the thermal calculation for the distribution board. With IP20 protection it belongs in a distribution board, and operation is limited to the indoor – general environment and −10 to +40 °C. The cross-section of the conductors connected is a maximum of 2 × 1.5 mm² or 1 × 2.5 mm². If the module is outside the guarded space, separate the bus feed with a JA-110T isolator.
Installation example
Always connect the bus with the system power completely switched off. Mains devices may only be connected by a qualified person.
Fit the module onto the DIN rail.
Connect the bus cable to the terminals: +U red, GND black, A yellow, B green.
After the system is switched on, a flashing yellow indicator shows that the module has not been enrolled into the system.
In F-Link, on the Devices tab, select the position and switch on the enrolment mode with the Enrol option.
Press the Manual/Learn button. The module is enrolled into the system and the yellow indicator goes out.
In Internal settings, specify which programmable outputs the module is to respond to and whether manual control by the button is permitted.
Test the function. Once the relay has switched, the red indicator lights up.
Connect the appliance control to the relay terminal block.
Related products

JB-110N
Bus PG power output module

JB-111N
Bus signal PG output module

JB-118N
Bus signal PG output module - 8 outputs

JA-120N
Bus module for control of an electric lock

JA-114HN
Bus four-input and four-output module

JB-165N-PLUG
Smart Socket with Consumption Measurement (Schuko)

JA-150N
Wireless power output module PG

JA-151N
Wireless signal output module PG

AC-160-C
Mounting-box-fitted wireless multifunctional power relay

JB-160N-PLUG
Smart Wireless Plug (French)

JB-164N-PLUG
Smart Socket with Consumption Measurement (French)

JB-162N-PLUG
Wireless plug with external output (French)
Help us improve the catalog
Missing something, or found a mistake? Let us know.