JB-118N
Bus signal PG output module - 8 outputs
A universal output module for a mounting box. Eight outputs, each switching a load of up to 100 mA.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption - outputs off/on
- 5 mA/10 mA
- Current consumption for cable selection
- 10 mA
- Maximum current from +U output (electronic fuse)
- < 100 mA (all connected devices must be included in current calculations)
- Maximum switched current/voltage for each output
- 100 mA/38 V
- Dimensions
- 77 x 40 x 15 mm
- Weight
- 26 g
Basic description
The module copies the programmable outputs assigned from the control unit. Directly from the mounting box, it controls devices such as visual indication elements, radio communicators, power relays and the like.
- The option of setting several modules the same way, so that their outputs react identically
- Outputs switched according to the setting of sections or an alarm in them as well
- Clear LED indication of the outputs
- Powered directly from the bus; it needs no separate power supply
Why choose this product
Load capacity for particular appliances
The outputs can switch voltages of up to 38 V. The current limit applies to each output separately.
- A load of up to 100 mA on each output (indication elements, communicators, relays and so on)
- A protected 12 V power output, with the total consumption of all connected devices under 100 mA
Frequently asked questions
For powering the equipment connected to the outputs, typically visual indication or a radio communicator. Thanks to it, the connected device does not need a power supply of its own.
No. The outputs are signal outputs and serve to control power relays or indication. For switching a mains load directly, use the JB-110N or the JA-110N-DIN.
You use the DIP switch to set the position for the first terminal and the other seven follow on from it. The step is eight positions (1, 9, 17 and so on), so the outputs always occupy a continuous block. Plan the numbers of the PG outputs so that they follow on from each other.
Technical specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption - outputs off/on
- 5 mA/10 mA
- Current consumption for cable selection
- 10 mA
- Maximum current from +U output (electronic fuse)
- < 100 mA (all connected devices must be included in current calculations)
- Maximum switched current/voltage for each output
- 100 mA/38 V
- Dimensions
- 77 x 40 x 15 mm
- Weight
- 26 g
- Classification
- Security grade 2/Environmental class II (according to EN 50131-1) Only when installed into the JA-194PL or JA-195PL mounting box together with the JA-111H TRB module!
- Operational environment
- indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 50581
Warning
- The module is not intended for switching power loads directly; it serves to control power relays. Exceeding the current or voltage ceiling of a single terminal is outside the specification of the output. If the +U terminals are overloaded, the voltage is disconnected and only returns once the current has dropped. The addressing cannot be set to any arbitrary position: the DIP switch jumps in steps of eight, so the eight outputs always occupy a continuous block. Mounting on a DIN rail requires a suitable holder. Security grade 2 applies solely in a JA-194PL or JA-195PL box with a JA-111H TRB module. Connect the bus with the power completely off. Operation is limited to the indoor – general environment, −10 to +40 °C and 75 % RH non-condensing. If the module is outside the protected area, separate the bus feed with a JA-110T isolator.
Installation example
Always connect the bus with the system power completely switched off.
Use the DIP switch to set the number of the PG output or of the section that terminal 1 is to react to. The following terminals react to the next positions with higher numbers.
Connect the bus cable to the bus terminals.
Place the module in a JA-19xPL box, or fit it onto a DIN rail with a suitable holder.
Switch the system on and test the function. A switched output lights up red.
Check that, with all the outputs used switched on, the supply voltage at the bus terminals is higher than 9 V. All devices powered from the +U terminals must be connected during the test.
Check that the current switched through a single terminal stays within the limits of the output.
Related products

JB-110N
Bus PG power output module

JA-110N-DIN
Bus DIN power output module

JB-111N
Bus signal PG output module

JA-120N
Bus module for control of an electric lock

JA-114HN
Bus four-input and four-output module

JB-165N-PLUG
Smart Socket with Consumption Measurement (Schuko)

JA-150N
Wireless power output module PG

JA-151N
Wireless signal output module PG