JA-151N
Wireless signal output module PG
A universal output relay for control circuits. An open NO / NC contact for switching up to 2 A of resistive load.
Product line
- JABLOTRON 100+
- JABLOTRON Mercury
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- 12 V DC (10 ... 16 V)
- Communication band
- 868.1 MHz
- Current consumption if relay switched on/off
- 18 mA/35 mA
- - Maximum switching voltage
- 50 V AC/60 V DC
- - Resistive load (cos φ=1)
- max. 2 A
- - Minimum switching current
- 10 mA
- Dimensions
- 82 x 50 x 16 mm
Basic description
The module copies the selected PG output from the control unit. It switches the control of devices such as an electric door lock or blocking and indication circuits.
- The option of assigning one PG output to several modules, whose outputs then copy it simultaneously
- Switching according to the setting of the selected section or an alarm in it as well
- Clear LED indication of the status
Why choose this product
Load capacity for particular appliances
The output relay switches AC voltages up to 50 V and DC voltages up to 60 V. The switched current has both an upper and a lower limit.
- Purely resistive load up to 2 A
- Control circuits (electric door lock, blocking, indication) with a current from 10 mA
Frequently asked questions
The JA-151N is the signal version: it is powered from a low DC supply and its contact is intended for extra-low-voltage circuits. The JA-150N is the power version, powered directly from the mains. For an electric door lock, blocking and indication use the JA-151N; for lighting and a fan use the JA-150N.
To the status of a selected PG output, to the setting of a section, or to an alarm in a section. You select the mode with the configuration switches on the board and set the PG outputs in F-Link on the PG outputs tab.
It can, into the connector on the board. The recommended types are the AN-80 and the AN-81. The jumper above the connector has to be opened at the same time, otherwise the antenna will not work correctly.
Technical specifications
- Power
- 12 V DC (10 ... 16 V)
- Communication band
- 868.1 MHz
- Current consumption if relay switched on/off
- 18 mA/35 mA
- - Maximum switching voltage
- 50 V AC/60 V DC
- - Resistive load (cos φ=1)
- max. 2 A
- - Minimum switching current
- 10 mA
- Dimensions
- 82 x 50 x 16 mm
- Operational environment
- Indoor general
- Operating temperature range
- -10 to + 40 °C
- Also complies with
- ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
Warning
- The contact is a signal contact, so a mains load cannot be switched through it. The controlled circuit must draw at least the specified minimum contact current. Without a JA-11xR radio module in the control unit, the module does not work. Only one control unit can be enrolled to the module. Several modules with the same switch settings switch simultaneously. If you are using an additional antenna, open the jumper above its connector, otherwise the antenna will not work correctly. Operation is limited to the indoor – general environment.
Installation example
Use the configuration switches to set the number of the output or section that the relay is to react to, following the setting tables in the manual.
If you are using an additional antenna, plug it into the connector on the board and open the jumper above the connector.
Connect the power cable to the power terminal block and switch the power on.
After it is first connected, the yellow indicator lights permanently. Press the enrolment button briefly to make it flash and open enrolment mode, then press Send enrolment signal in F-Link.
Test the function of the module; the switching of the relay contacts is indicated by the red indicator.
Only at the very end, connect the switched device to the relay terminal block.
Related products

JA-150N
Wireless power output module PG

AC-160-C
Mounting-box-fitted wireless multifunctional power relay

JB-160N-PLUG
Smart Wireless Plug (French)

JB-164N-PLUG
Smart Socket with Consumption Measurement (French)

JB-162N-PLUG
Wireless plug with external output (French)

AC-160-DIN
Wireless multifunctional relay for DIN-rail installation

JB-161N-PLUG
Smart Wireless Plug (Schuko)

JB-163N-PLUG
Wireless plug with external output (Schuko)

JB-165N-PLUG
Smart Socket with Consumption Measurement (Schuko)

JB-110N
Bus PG power output module

JA-110N-DIN
Bus DIN power output module

JB-111N