JB-111N
Bus signal PG output module
A universal signal relay for a box or a control unit. An open NO / NC contact for switching logic inputs or loads of up to 2 A.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K, JA-152KRY
Check compatibilityKey specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption (relay off/on)
- 5 mA/25 mA
- Current consumption for cable selection
- 25 mA
- Maximum switched voltage
- 50 V AC/24 V DC
- Maximum switched current
- 2 A
- Minimum switched current
- 10 mA
- Dimensions
- 78 x 40 x 15 mm
Basic description
The module copies the programmable outputs assigned from the control unit. It is installed directly in the control unit or in the JA-190PL, JA-194PL or JA-195PL universal boxes. It switches the power supply or the control of appliances such as gate actuators and motorised locks.
- It takes up no position in the system. The output copied is set with the switches directly on the module
- Powered directly from the bus; it needs no separate power supply
Why choose this product
Use for particular applications
Compared with the power versions, the relay is suitable for switching low-voltage control inputs, typically on garage door and entrance gate actuators. A load capacity of up to 2 A also makes it possible to switch the power supply of electromagnetic or motorised door locks, or of small LED lighting with minimal current consumption.
- Load capacity up to 2 A at 24 V DC or 50 V AC.
- Consumption from the bus of 5 mA in the idle state / 25 mA when the relay is switched on.
Frequently asked questions
It cannot. The contact is a signal one, intended for extra-low-voltage circuits. For mains appliances, use the power version JB-110N or JA-110N-DIN.
It is not. The output contact has no overload protection, so protect the switched circuit separately and size the protection to the contact limit.
To control an electric door lock, a blocking circuit or an indication, linked to a programmable output or to the state of a section. These are always extra-low-voltage circuits within the contact limits, with protection of their own.
Technical specifications
- Power
- from control panel BUS 12 V DC (9 … 15 V)
- Current consumption (relay off/on)
- 5 mA/25 mA
- Current consumption for cable selection
- 25 mA
- Maximum switched voltage
- 50 V AC/24 V DC
- Maximum switched current
- 2 A
- Minimum switched current
- 10 mA
- Dimensions
- 78 x 40 x 15 mm
- Weight
- 23 g
- Classification
- Security grade 2/Environmental class II (according to EN 50131-1) Only when installed into the JA-194PL or JA-195PL mounting box together with the JA-111H TRB module!
- Operational environment
- indoor general
- Operational temperature range
- -10 °C to +40 °C
- Average operational humidity
- 75 % RH, non-condensing
- Certification body
- Trezor Test s.r.o. (no. 3025)
- Complies with
- EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50130-4 ed. 2+A1, EN 55032, EN 50581
Warning
- The output contact contains no overload protection, so protect the switched circuit separately and size the protection to the contact limit. The contact is intended for extra-low-voltage circuits; mains appliances must not be switched through JB-111N. The circuit controlled must draw at least the specified minimum current; below that it is outside the contact specification. Outside the prescribed assembly with a mounting box and the tamper module, security grade 2 cannot be relied on. Connect the bus with the power supply completely switched off, and the voltage on it must not drop below the prescribed limit while the relay is switched on. The number of modules in the system is limited by the total current drawn from the control unit. Operation is limited to the indoor – general environment. If the module is outside the protected space, separate the bus feed with a JA-110T isolator.
Installation example
Always connect the bus with the system power completely switched off.
Using the configuration switch, set the number of the programmable output or section the relay is to respond to, according to the tables.
Connect the bus cable to the bus terminals.
Place the module in a JA-19xPL box or in the control unit enclosure.
Switch the system on and test the function.
Check that the supply voltage at the bus terminals (red, black) is greater than 9 V while the relay is switched on.
Connect the device to be switched to the relay terminal block and provide external protection for it.
Related products

JB-110N
Bus PG power output module

JA-110N-DIN
Bus DIN power output module

JB-118N
Bus signal PG output module - 8 outputs

JA-120N
Bus module for control of an electric lock

JA-114HN
Bus four-input and four-output module

JB-165N-PLUG
Smart Socket with Consumption Measurement (Schuko)

JA-150N
Wireless power output module PG

JA-151N
Wireless signal output module PG

AC-160-C
Mounting-box-fitted wireless multifunctional power relay

JB-160N-PLUG
Smart Wireless Plug (French)

JB-164N-PLUG
Smart Socket with Consumption Measurement (French)

JB-162N-PLUG
Wireless plug with external output (French)
Help us improve the catalog
Missing something, or found a mistake? Let us know.