JA-120N

Bus module for control of an electric lock

A bus module that both controls and powers an electromagnetic lock or an access control unit. The lock is opened by a selected PG output of the control unit or by a release button on the IN input.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K

Check compatibility

Key specifications

Power
from the control panel BUS (9 … 14 V) 3x NiMh rechargable accumulator type AA Eneloop 1900 mAh Please note: Batteries are not included
External power
+12 V
Current consumption in standby mode
10 mA
Current consumption for cable choice
60 mA
Pulse (1s)
600 mA
Continuous
300 mA
Dimensions
90 x 90 x 35 mm

Basic description

The JA-120N powers and controls electromagnetic locks and access control units directly from the system bus. It is intended for doors to which running a separate power supply cable would be difficult.

  • The lock is both opened and powered from a single DOOR output. The inrush current is covered by the rechargeable batteries inside the module.
  • The module takes both power and commands from the system bus. With a standard lock, you therefore do not need a separate power supply at the door.
  • The DOOR output supplies +12 V, 600 mA pulsed for 1 s and 300 mA continuously.
  • Security grade 2 and environmental class II according to EN 50131-1.

Why choose this product

Output for an electric lock

The module both opens and powers the lock: the voltage for it is supplied directly by the DOOR output. When the output should switch on, for how long and with what logic is set in the F-Link program on the Devices tab, in the Internal settings.

  • When the IN input is activated, the output switches on for the set maximum time, 10 s at most
  • IN input property: Off, Manual control or System
  • A reverse lock and inverted logic of the DOOR output both require an external +12 V power supply, for example the DE 06-12

Rechargeable batteries for the opening pulse

When opening, an electric lock demands a current surge that the bus alone cannot cover. The module therefore has its own NiMH rechargeable batteries and takes the energy for opening from them. How often the door is opened and how long the lock stays energised therefore already belongs in the design.

  • 3× AA NiMH Eneloop 1900 mAh rechargeable battery, order code BAT-1V2-NIMH
  • With a lock drawing 230 mA, approximately 618 openings with a 10 s pulse, 1241 with a 5 s pulse and 3114 with a 2 s pulse
  • Recharging after one activation takes 387 s, 193 s or 55 s depending on the pulse length

Wiring and security

The module comes to the door already in a box, which you screw into place. The tamper contact monitors opening of the cover; if you place the module in another enclosure that is already protected, you disable it with the Active tamper parameter. The release button can be blocked by setting the section to which the module is assigned, but only if the IN input has the Manual control property set. With the Unlock the IN input during a fire alarm parameter, the blocking can be cancelled during a fire alarm so that the door can be opened.

  • Powered from the 12 V DC bus in the range 8 to 15 V; current draw 7.6 mA nominal, 60 mA maximum
  • Function button during communication fault keeps the lock opening even without a connection to the control unit
  • The IN input is unbalanced and does not monitor the wires for short circuits or breaks