JB-TS-NTC10K
External sensor for JABLOTRON thermostats
Passive cable temperature sensor for JABLOTRON room thermostats. It measures where the thermostat's built-in sensor cannot reach, most often in the floor. It needs neither its own power supply nor a position in the system.
Key specifications
- Maximum operating temperature range
- -50 to +200 °C (may be limited by the type of sensor, specified in the instructions for use)
- Sensor
- Pt, Ni, NTC
- Degree of protection
- IP 67 according to EN 60529
- Housing materiál
- Brass
- Housing diameter/length L
- 4.6 mm / 24 mm
- Supply cable
- Shielded silicone 2 x 0.22 mm2
- Cable resistance
- 0.16 Ω per 1 m of cable for a 2-wire connection
Basic description
There are two probes, and each belongs to a different type of device. The JB-TS-NTC10K is intended for room thermostats, where it monitors the floor temperature. The JB-TS-PT1000 is intended for external thermometers, for which it measures outside their own housing. Therefore choose according to the device to which you are connecting the probe.
- With it, the thermostat monitors the floor temperature, so the underfloor heating does not overheat.
- Brass housing with IP67 protection on a three-metre cable.
Why choose this product
Floor temperature measurement
With the sensor, the thermostat measures the floor temperature and keeps it below the set limit; it continues to control normal regulation according to the room air temperature. The sensor itself evaluates nothing and has no settings of its own; it works as an extended sensor of the thermostat.
- Sold separately; not included in the thermostat package.
- Besides the floor, it also measures in saunas, swimming pools, freezers, non-aggressive liquids or on pipes.
- Response under 7 s in water flowing at 0.4 m/s.
Frequently asked questions
No. It belongs with JABLOTRON room thermostats that have an input for a floor sensor. You can check whether the model you have chosen has one in the compatibility table.
The type of sensing element and the device it belongs to. The room thermostat reads an NTC thermistor, the external thermometer reads a Pt resistance sensor. Each host device therefore has its own probe.
Technical specifications
- Maximum operating temperature range
- -50 to +200 °C (may be limited by the type of sensor, specified in the instructions for use)
- Sensor
- Pt, Ni, NTC
- Degree of protection
- IP 67 according to EN 60529
- Housing materiál
- Brass
- Housing diameter/length L
- 4.6 mm / 24 mm
- Supply cable
- Shielded silicone 2 x 0.22 mm2
- Cable resistance
- 0.16 Ω per 1 m of cable for a 2-wire connection
- Response time
- τ 0.5 <7 s (in flowing water 0.4 m·s -1 )
Warning
- Preferably do not extend the cable; an extension may distort the measured temperature. In the floor, run the sensor in a protective conduit, at least 30 cm from the wall and midway between the heating loops.
Installation example
Connect the sensor to the thermostat input intended for the floor sensor.
Related products

JB-150N-HEAD
Wireless thermostatic head

JB-EXT-TH-R
Wireless outdoor thermometer

JA-111TH
Bus temperature detector

JA-151TH
Wireless temperature detector

JB-EXT-TH-B
Bus outdoor thermometer

JB-111TP
Bus room thermostat

JB-111TP-AN
Bus room thermostat - anthracite

JB-151TP
Wireless room thermostat

JB-151TP-AN
Wireless room thermostat - anthracite

JB-111TH
Bus temperature and humidity sensor with thermostat function

JB-111TH-AN
Bus temperature and humidity sensor with thermostat function - anthracite

JB-112TH
BUS temperature, humidity and CO₂ sensor with thermostat function
Help us improve the catalog
Missing something, or found a mistake? Let us know.